CM-series
Stage Wedge Monitors
Item ref: CM10A 178.690UK
CM10 691178. UK
User Manual
Version 1.0
Caution: Please read this manual carefully before operating
Damage caused by misuse is not covered by the warranty
CM-series Stage Wedge Monitor User Manual
Introduction
Thank you for choosing a Citronic CM-series stage wedge monitor. These units are available in passive and active
versions and can be positioned free-standing or pole-mounted via the 35mm socket. Please read this manua to a eve l chi
optimum performance from your speaker cabinet and avoid damage through misuse.
Package Contents
• CM-series stage wedge monitor
• Mains lead(s)
• User manual
If you find any part is missing or the product has arrived with any problems, please contact your retailer at once.
This product contains no user-serviceable parts, so make no attempt to try to fix or modify this item yourself as this will
invalidate the warranty. We recommend you keep the original package and proof of purchase for any possible
replacement or return issues.
Please note below for active models
Warning
To prevent the risk of fire or electric shock, do not expose any of the components to rain or moisture.
Avoid impact to any of the components.
No user serviceable parts inside - refer servicing to qualified service personnel.
Safety
• Please observe the following warning conventions
CAUTION: RISK OF ELECTRIC SHOCK
DO NOT OPEN
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this
unit
This symbol indicates that there are important operating and instructions in the maintenance
literature accompanying this unit.
• Ensure that the correct mains lead is used with adequate current rating and mains voltage is as stated on the un it
• Avoid ingress of water or particles into any part of the housing If liquids are spilled on the cabinet, stop using .
immediately, allow the unit to dry out and have checked by qualified personnel before further use
Warning: this unit must be earthed
Place ment
• Keep the electronic parts out of direct sunlight and away from heat sources.
• Position the cabinet on a stable surface or stand that is adequate to support the weight of the product.
• Allow adequate space for cooling and access to controls and connections at the rear of the cabinet.
• Keep the cabinet away from damp or dusty environments.
Cleaning
• Use a soft dry or slightly damp cloth clean surfaces of the cabinet to
• A soft brush can be used to clear debris from controls and connections without damaging them
• To avoid damage, do not use solvents to clean any parts of the cabinet.
CM-series Stage Wedge Monitor User Manual
Passive panel layout
Both SPK t sockets are wired to 1+/1- in parallelinpu
Active panel layout
Setting up
For live stage monitoring osition your CM-series stage wedge on the floor facing upward toward the listener. , p
The dge can also be mounted onto a 35mmØ speaker stand or wall bracket for use as a we PA speaker.
The coaxial main driver has an integral tweeter r full-range output from a focused, compact cabinet. fo
Passive models are connected via either of the two SPK input sockets, wired 1+/1- (pins 2 not connected).
Connect to only one of these from the amplifier (another passive speaker may be connected to the other)
Ensure that the CM passive monitor can handle the power from the amplifier a 8 (or 4 if 2 are connected). t Ω Ω
Active models have 2 independent inputs …
Input A (2, 9) can accept a line level signal from a mix , audio source or electrer onic instrum ent.
The volume level of input A is controlled by the VOLUME A rotar control (y 15).
Input B ( ) switchable accept either a microphone directly or a line input via the MIC/LINE button (12). 11 is to
The volume level of input B is controlled by the VOLUME B rotar control (13). y
The overall output level of the monitor is governed by the MASTER volume control (6).
The mix of Input A and Input B (and Bluetooth as described below) can be output to further active speakers
or monitors from the MIX OUT XLR connector (10).
A stereo HEADPHONE output (14) enables personal headphone monitoring erned by a volume control (7). , gov
1.
DSP setting indicator LEDs
2.
LINE A input combo Jack/XLR
3.
Bluetooth on/off & pairing button
4.
DSP rotary selector
5.
Bluetooth & Amplifier status LEDs
6.
MASTER volume control
7.
HEADPHONE output volume control
8.
Power on/off switch
9.
LINE A input RCA (L+R)
10.
MIX line output XLR
11.
MIC/LINE B input combo Jack/XLR
12.
Input B MIC/LINE level selector
13.
MIC/LINE B volume control
14.
HEADPHONE 6.3mm stereo output
15.
LINE A volume control
16.
IEC mains inlet & fuse holder