Christie XenoliteĀ® lamps
and Christie Solariaā„¢
Series projectors
Usage best practices
How to calculate the amount of light required
The basic formula to calculate this theoretical light requirement is:
Lumens (L) = Average Screen Brightness desired (average fL)
X Screen Area (sq ft)
ā€¢ī˜ Givenagoodlightdistribution,theī˜ā€œAverageScreenBrightnessā€ī˜
canbeestimatedbymultiplyingthecenterbrightnessdesiredby
0.95.Generallyacceptedpracticeforthetargetcenterbrightness
is:14fLfor2Dand4.5fLfor3D(lightmeasurementtakenthrough
3Dglasses).
ī˜žAfteryouhavetheī˜ā€œLumensā€ī˜numberyouwoulddivideitbyall
signiī™­cantsystemefī™­ciencies.Someexampleswouldbe:
ā€¢ī˜
Screen gain: 1.0 to 2.4.  Silver screens are   a 2.4. This is very important
partofthisequationandcareshouldbetakentomakesurethis
numberisaccurate.Ifthescreeninquestionisnot  new then the
overall gain should be   measuredproperly. Any degradation  
ordebrisonthescreenwillreducethescreengain.
ā€¢ī˜ Port window efī™­ciency: 96%   efī™­ciency is typical for good  port glass.
ā€¢ī˜ LossduetocolorcorrectionrequiredformeetingDCIcolor
speciī™­cations:97%efī™­ciencyistypical.
ā€¢ī˜ 3Dsystemlightefī™­ciency:thisnumbercanbeanywhere
from10%to30%efī™­ciencydependingonthe3Dsystemused.
ā€¢ī˜ Othereffectslikedownangleandscreencurvedomakea
differenceforlightdistributionbuttheyonlyeffectthese
calculationsifthey excessive.are
ī˜ī˜ Calculation:Lumens Required (L) = Lumens (L) / (Screen Gain X Port
Window Efficiency X Color Correction Efficiency X 3D Efficiency)
 Theresultingī˜ā€œLumensRequiredā€ī˜numberyougetwouldbethe
ā€œMINIMUMlumenrequirementā€ī˜tomeetthedesiredlightlevels.
How to select the right projector/lamp combination
that will provide enough light to satisfy screen
brightness requirements
Thereshouldbeenoughbrightnessavailableevenattheendof
thelamp’slifetomeetyourspeciī™­edcenterbrightnessrequirement.
Yourcompany’slampchangingpolicymayneedtobereviewedto
makethisdecision.
Thereisanaturalbrightnessdrop-offthatoccurswithanyXenonlamp
duringitslife.Thisbrightnesscurveistypicallysharpatthebeginning
ofthelamp’slifeanddropsslowerafterthisinitialperiod.Leaving
thelampat100%powerthroughoutitslifewouldgivethistypical
brightnesscurve:
Lamp life
Starting lamp at 100% power
Maintaining lamp at 100% power
Point at which
brightness is
unacceptable
Approximately
50% brightness
100% Rated
brightness
(lamp/projector
combination)
Brightness
ī˜žThisinitialdrop-offinbrightnessismainlyduetothere-shapingofthe
electrodesinsidethelamp.The betweentheelectrodesinsidethearc
lampwillmoveslightlyduringthisperiod.Re-aligningthelampoften
canminimizethisdrop-off.Thisre-alignmentshouldbedoneatleast
everytimetheequipmentisserviced.Themorefrequentthisisdone,
themorelightefī™­ciencycanbepreserved.
ī˜100%Ratedbrightnesswouldindicatetheuseofanewlamprunning
at100%power.
USAGE BEST RACTICES P
Optimize your Christie
digital cinema system
Christie Xenolite ®     lamps can produce remarkable brightness
and color consistency with excellent resistance to ī™®icker,       
ignition difī™­culty and explosion. With this superior performance       
comes great economy. Here some usage guidelines    are   
that can be applied to get optimum performance from the         
Christie Xenolite lamp and Christie Solaria     ā„¢ī˜  Series projector
combination. If you need technical support to help you        
with this, please do not hesitate to contact Christie        
technical support.
1
 ItisNOTrecommendedtorunalampinthisway.Ifthisisdonethen
thebrightnesslevelwillnotbemaintainedforverylongandthelamp
lifewillbereduced.
ī˜›ī˜ ThischartdescribestherecommendedoperationofanyXenonlamp.
 Understandingthisbrightnesscurvewillhelpwhendecidingwhich
projectorandlamptouse.Itisimportanttoselectalampthatcan
producetherequiredbrightnessattheendofitslife.
Hereishowthisisestimated:
ā€¢ī˜ Selectalampforanexamplefromtheī˜ā€œLampBrochureā€ī˜and
reduceitsmaximumlumenvaluebyabout25%asastartingpoint.
Thiswouldbeanestimateofthebrightnessthatthelampcan
achieveatorneartheENDofitslifeatthestatedwarranty.For
higherwattagelampsthisvaluewouldbemorelike30%or35%.
Ifyouintendonrunningthelamplongerthanthestatedwarranty
thenyouwouldincreasethispercentage.Callthisresultinglumen
valuetheī˜ā€œmaximumagedbrightness.ā€
ā€¢ī˜ Taketheī˜ā€œminimumlumensrequiredā€ī˜numberandselectthelamp/
projectorcombinationthatcancoverthiswithitsī˜ā€œmaximumaged
brightnessā€ī˜value.Itisbesttobeconservativewiththisselectionto
makesuretherequiredbrightnesscanbereached.
How to preserve lamp life with the proper projector
operating environment
Properoperatingenvironmentconditionswillpreservelamplife.
 Roomtemperature:Comfortableroomtemperatureisusually
acceptable.Between50°Fand95°F(10°Cī˜ā€“ī˜35°C).
ī˜žī˜ Roomhumidity(noncondensing):20%to80%.
ī˜ī˜ Externalexhaustextraction:Usetheī˜ā€œLampBrochureā€ī˜toī˜ī™­ndthe
properairī˜ī™®owinCFMthatisrequired:
ā€¢ī˜ Makesurethisairī˜ī™®owismaintainedanytimetheprojectorison.
Addthismeasurementtoallroutineservicevisits.
ā€¢ī˜ Makesurethattheairductsystemhasadamperfeaturewhich
closes totheoutsideairwhenthesystemispowereddown.off
Thiswillpreventdirtymoistairfrombeingpulledbackdown
intotheprojectorwhenthesystemisoff.
How to ensure proper lamp house electrical connections
to the lamp
Xenonlampsoperateatveryhighcurrentoramperagelevels.Because
ofthis,anyelectricalconnections verycritical.Wheninstallingalampare
makesuretheseconnections tightandsecure.are
 Alooseorbadconnectioncancausetheconnectortoburnwhichin
turnwilleitherbreaktheelectricalconnectionoroverheattheendof
thelampcausingthesealinsidethelampendtofail.Thiswillresultin
alampthatwillnotignite.
ī˜žī˜ Donotuseanyconnectorsthat discoloredorburnt.Replaceanyare
discoloredconnectorsbeforeinstallinganewlamp.
ī˜
Inspect both end  connectors for discoloration  at every routine service visit.   

Lamps exhibiting burnt or   discoloredends not covered under warranty. are   
How to determine average expected life
In the ā€œLamp Brochureā€ you will ī™­nd an ā€œEstimated average expected lifeā€ī˜           
number for each lamp/projector combination.   

This number is  a  guideline to help you determine how   longaparticular
lamp can be operated   under optimal conditions  as described here. 
ī˜ž
If the operating situation   is not optimal  then shortera lamp life 
can be expected. 
ī˜
Non-optimal conditions would include:  
ā€¢ī˜ Startingthelampoutnearorabove100%powerandrunning
itthiswaythroughoutitslife.
ā€¢ī˜ Notprovidingadequateairextraction.
ā€¢ī˜ Pooroperatingenvironment.
ā€¢ī˜ Changingthepowerleveldrasticallyupandthenbackto
accommodatetwodifferentlightlevelrequirementssuch
as2Dthen3D.
Christie XenoliteĀ® Lamp Champion Warranty
ChristieXenolite®lamps ofveryhighqualityandanyfailureisunlikely.are
Ifalamphasfailedforsomereasonthenaservicetechnicianshouldcheck
thesystemandoperatingpracticestomakesurethatthelampisbeing
usedproperly.AllChristieXenolitelamps coveredunderwarrantyare
againstanymanufacturerdefects.Theperiodoftimeisbasedonthe
warrantyhoursofoperationgivenintheī˜ā€œLampBrochureā€ī˜andaperiod
ofoneyearfrominvoicedatewhichevercomesī˜ī™­rst.

Ifa     warranty claim is required then prompt   taken.action must be
A          ī˜ā€œXenolite Lamp Warranty Claim Formā€ must be ī™­lled out completely
and the on the  submitted, following  instructions     form. These forms
are        in the lamp box or they can be obtainedby   contacting the Christie
ofī™­ce your  located in region. information on the   Please see contact   
back  of this guide.
ī˜žī˜ Iftherequestisunusualanditissuspectedthatthelampdidnot
causethefailurethenChristiewillcontactthepersonmakingtheclaim
toverifytheoperatingconditions.Thisistohelppreventrepeating
failurescausedbysomethingotherthanthelamp.
USAGE BEST RACTICES P
Desi d lamp lifere
Lamp power and brightness over time
Optimal conditions
Brightness
Power
Acceptable brightness range Brightness is unacceptable
75%
95% 100%
90%
85%
2


Produktspezifikationen

Marke: Christie
Kategorie: Projektorzubehƶr
Modell: CDXL-45

Brauchst du Hilfe?

Wenn Sie Hilfe mit Christie CDXL-45 benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Projektorzubehƶr Christie

Bedienungsanleitung Projektorzubehƶr

Neueste Bedienungsanleitung für -Kategorien-