INSTALLATION MANUAL
MANUEL D’INSTALLATION
MANUAL DE INSTALACIÓN
INSTALLATIEHANDLEIDING
MANUALE D’INSTALLAZIONE
JP-DA
Video door station
Poste de porte vidéo
Video portero
Videodeurpost met kunststof
opbouwbehuizing
Postazione videocitofonica
esterna
JP-DV
Vandal-resistant video door station
Portier vidéo résistant au vandalisme
Video portero antivandálico
Videodeurpost met metalen
antivandalisme-opbehuizing
Postazione videocitofonica esterna
resistente agli atti vandalici
JP-DVF
Vandal-resistant video door station
Portier vidéo résistant au vandalisme
Video portero antivandálico
Videodeurpost met inox antivandalisme-
inbouwbehuizing
Postazione videocitofonica esterna
resistente agli atti vandalici
JP-DA, JP-DV, JP-DVF
VIDEO DOOR STATION
POSTE DE PORTE VIDÉO
VIDEO PORTERO
VIDEODEURPOST
POSTAZIONE VIDEOCITOFONICA ESTERNA
2
EnglishFrançaisEspañolNederlandsItaliano
PRECAUTIONS
General Prohibitions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to Water General Precautions
WARNING
Negligence could result in death or serious injury.
1. Do not dismantle or alter the unit. Fire or electric shock could
result.
2. Existing wiring such as chime wiring, etc. may contain high
voltage AC electricity. Damage to the unit or electric shock
could result. Wiring and installation should be done by a
qualifi ed technician.
3. This unit is not an explosion-proof unit. Do not install or use
the unit in locations that are fi lled with fl ammable gas such as
oxygen rooms. Fire or an explosion could result.
CAUTION
Negligence could result in injury to people or damage to property.
1.
Before turning on power, make sure wires are not crossed or
shorted. If not, fi re or electric shock could result.
2.
Do not install or make any wire terminations while power supply
is plugged in. It can cause electrical shock or damage to the unit.
GENERAL PRECAUTIONS
1. The door station is weather resistant, but do not spray high
pressure water on door station directly. Unit trouble could result.
PACKAGE CONTENTS
Verify that the following parts are included.
JP-DA
Front panel Main unit Installation manual
JP-DV
The unit Special screwdriver Transparent nameplate (x2) Installation manual
JP-DVF
The unit Flush mount back box
Special screw (x4)
Transparent
nameplate (x2) Installation manual
Hexagonal wrench
INSTALLATION
Mounting locations
"Do not install video door station in any of the following locations where lighting or the ambient environment could impact the
display on the video monitor due to the characteristics of the door station's camera."
a Locations subject to
direct sunlight
b Under street lights or door
lights
c Other locations subject to strong
lighting or backlighting conditions
3
English Français Español Nederlands Italiano
Mounting positions and image view area
Wide picture
Zoom picture
The zoom position can be changed.
(Refer to the master station's operation manual.)
The factory setting is "Center" for Zoom mode.
Approx.
1,300 mm
(4' 3")
Approx. 600 mm (2')
Approx. 950 mm (3'
1"
)
Objects appear smaller
due to greater distortion in
the surrounding sections
compared to the central
section, but a wider area is
displayed.
The display range is a rough
estimation and may change
due to the installation
environment.
Wide picture
Up/Down
Mounting position
1,500 mm (5')
Left/Right
A
pprox. 1,300 mm (4' 3")
A
pprox. 2,200 mm
(7' 2")
A
pprox. 900 mm
(2' 12")
500 mm (20")
1,500 mm (5')
Unit center
Approx. 2,000 mm
(6' 7")
Approx. 1,300 mm (4' 3")
Approx. 700 mm
(2' 4")
Mounting position
1,300 mm (4' 3")
Unit center
1,300 mm (4' 3")
500 mm (20")
Approx. 170°
Zoom picture (when mounting position is 1,500 mm (5'))
Left/Right
Up/Down
Approx. 500 mm (20")
Zoom <Up>
Approx. 750 mm (2' 5")
Approx. 1,500 mm
(5')
500 mm (20")
Unit center
1,500 mm (5')
Approx. 600 mm
(2')
Approx. 1,250 mm
(4' 1")
Zoom <Center> Zoom <Down>
Approx. 1,550 mm
(5' 1")
Approx. 750 mm
(2' 5")
500 mm (20")
Unit center
1,500 mm (5')
Zoom <Left> Zoom <Center> Zoom <Right>
Approx. 500 mm
(20")
Approx.
140°
Approx. 500 mm (20")
Approx.
950 mm (3' 1")
Approx. 950 mm (
3' 1"
)
Approx.
950 mm (3' 1")
Approx.
140°
Unit center
1,500 mm (5')
500 mm (20")
Cable
Use PE (polyethylene)-insulated PVC jacket cable.
Parallel or jacketed 2-conductor, mid-capacitance, non-shielded
cable is recommended.
N
ever use individual conductors, twisted pair cable, or coaxial cable.
2
JPW-BA
JP-DA JP-DV JP-DVF JP-4MED
Wiring distance
2
2
2
[A]
[B]
[C]
JPW-BA
JP-DA JP-DV JP-DVF
JP-DA JP-DV JP-DVF
JP-4MED
An area over a range of approx. 170° in a
500 mm radius from the camera displays.
(The display range is a rough estimation
and may change due to the installation
environment.)
Approx. 2,250 mm
(7' 5")
Approx. 1,850 mm
(6' 1")
Approx. 800 mm
(2' 8")
500 mm (20")
Approx.
85°Approx.
85°
Approx.
85°
Wire diameter
Ø0.65 mm
(22 AWG)
Ø0.8 mm
(20 AWG)
Ø1.0 mm
(18 AWG)
Ø1.2 mm
(16 AWG)
[A] Door station - master
station
50 m
(165')
100 m
(330')
100 m
(330')
100 m
(330')
[B] Door station - long
distance adaptor
100 m
(330')
150 m
(490')
200 m
(650')
200 m
(650')
[C] Long distance
adaptor - master
station
50 m
(165')
75 m
(245')
100 m
(330')
100 m
(330')


Produktspezifikationen

Marke: Aiphone
Kategorie: Gegensprechanlage
Modell: JP-DV

Brauchst du Hilfe?

Wenn Sie Hilfe mit Aiphone JP-DV benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Gegensprechanlage Aiphone

Bedienungsanleitung Gegensprechanlage

Neueste Bedienungsanleitung für -Kategorien-