Viking E-60-BN Bedienungsanleitung


Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Viking E-60-BN (8 Seiten) in der Kategorie Gegensprechanlage. Dieser Bedienungsanleitung war fĂĽr 9 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/8
The E-60 Series entry phones are compact,
vandal resistant, telephone line powered
speaker phones designed to provide two-way
handsfree communication. The 's compactE-60
size allows it to be mounted in a standard double
gang electrical box. The is available in fourE-60
different attractive finishes to match your door
hardware, light fixtures, etc. Replacement E-60
faceplates (PNL60) can be purchased
separately and are available in all four standard
finishes. The E-60’s blue LED continually
provides light for locating the push button in dark
locations, dims to indicate off hook and flashes
during incoming ring.
The model , ,E-60 entry phones can share a single phone line with house or small business telephones when used with a Viking C-200 C-250
C-500 or C-2000B Entry Phone controller. The entry phones can also be connected to an unused analog station port (programmed for ringE-60
down) on a phone system or connected directly to a telephone line when used with a auto dialer. TheViking model or K-1900-5 K-1900-30
E-60 features microphone and speaker volume controls, selectable auto answer for monitoring and intelligent call progress detection for automatic
hang-up when the call is completed. For outdoor installations where the unit is exposed to precipitation or condensation, the Series isE-60
available with Enhanced Weather Protection ( ). For more information on , see .EWP EWP DOD 859
PRODUCT MANUAL
Designed, Manufactured and Supported in the USA
C O M M U N I C A T I O N & S E C U R I T Y S O L U T I O N S
Entry Phones Now Mount in a Standard Double Gang Box
Features
E-60 Series
Double Gang
Entry Phones with LED
April 26, 2018
Applications
Specifications
VIKING
• Compact size: Front panel is the size of a typical double gang mid-size
wall plate
• Mounting: Flush mounts in a double gang electrical box (2.25” deep x
3.65” wide x 2.84” tall minimum) or surface mounts in a Viking model
VE-5x5 DOD 424(not included, see ) for mounting to a wall, post or
VE-GNP Gooseneck Pedestal (EWP recommended)
• Available in 4 standard faceplate finishes: Brushed Stainless Steel, Oil
Rubbed Bronze, Satin Black and Satin White
• PNL-60 faceplates: Replacement faceplates with matching screws
available in all four standard finishes
• Vandal Resistant Features: 18 gauge 304 stainless steel faceplate, 316
stainless steel push button, carbon fiber reinforced plastic speaker
screen, scratch resistant powder coating, hex drive mounting screws
• Weather Resistant Features: Mylar speaker, faceplate gasket, mic and
speaker gasket, internally sealed (IP67) push button switch, self draining
mic mount and UV stable weather resistant powder coating (excluding
E-60-SS 304 Stainless Steel faceplate)
• is designed to meet IP66 Ingress Protection Rating (see E-60-EWP DOD
859 for more information)
• Blue LED helps locate push button, indicate ringing and off hook
• Telephone line powered
• Microphone and speaker volume controls
• Programmable intelligent call progress detection for automatic hang-up on
CPC, silence, busy signal, or time out
• Selectable auto answer feature for monitoring
• Programmable VOX (mic/speaker) switching speed
• VE-LIGHT: VE-5x5 DODOptional faceplate light kit for use with the (see
859 for more information)
Power: Telephone line powered. Minimum 18V DC talk battery
voltage with a minimum loop current of 20mA. Loop current may be
boosted on low current lines with a Viking model Talk BatteryTBB-1B
Booster(see ).DOD 632
Dimensions: Faceplate: 4.875” x 4.938” x 0.17” (123.8mm x 125.4mm
x 4.3mm), Phone: 2.84” x 1.8” x 1.65” (72mm x 46mm x 42mm)
Shipping Weight: 1.2 lbs (0.55 kg)
Operating Temperature: -30° F to 150° F(-34° C to 65° C)
Humidity: Standard model: 5% to 95% non-condensing humidity,
EWP model: up to 100% humidity
Speaker Volume: Approximately 62db maximum @ 1m
Ring Voltage: 25V AC RMS minimum (for auto answer)
CPC Disconnect Time: 300ms minimum
REN: 0.8A
Connections: (2) gel-filled butt connectors
• Door or gate communication, business delivery entrances
• Use with a or to control on a single lineViking C-200 C-250 E-60
• Use with a to control 1 or 2 (expandable to 8) Viking C-500 E-60’s
and door/gate control on a single phone line
• Use with a to control 1 to 4 ’s and door/gateViking C-2000B E-60
control on a single phone line
• Provide unique front and back door chimes and paging when
used with a , and Viking SLP-1 SLP-4 C-2000B
• Residential, commercial and industrial door security
• Use with a or for automatic speedViking K-1900-5 K-1900-30
dialing on telephone lines or analog PABX/KSU station ports
• Use on any analog PABX station port with programmable
ringdown capability
E-60-BK
“Satin Black”
(fine texture satin
black powder paint)
E-60-WH
“Satin White”
(satin white
powder paint)
E-60-SS “Brushed
Stainless Steel”
(similar to brushed nickel)
Shown with optional VE-5x5
box and (not included)
E-60-BN
“Oil Rubbed Bronze”
(satin dark brown
powder paint with fine
copper metallic)
Installation
2
A. New Construction Flush Mounting
Step 1
Front of box should stick out approximately ½" from front surface of wall stud (this may
vary depending on the walls sheathing and siding thickness). Caution: Rough-In box
must be mounted and must stick out beyond the front surface of siding. LEVEL NOT
Step 2
To maintain a vapor barrier on outside wall applications, caulk around the box, filling any
gaps between the box and the rough opening. Apply caulk to any holes in the box around
wires, etc.
Step 3
When installing siding cut a hole just large enough for the Rough-In box opening.
Caution: Too large of a hole can cause plate misalignment and compromise the gasket
seal. Note: When mounting to 4 inch or less horizontal lap siding, a siding mounting block
can be used Contact siding installer for the correct mounting block. A sideNote:
mounting block is recommended when mounting to vinyl siding.
The E-60 is designed to be flush mounted into a standard double gang rough-in box with minimum
inside dimensions of 2.25” deep x 3.65” wide x 2.84” tall. The can also be surface mounted in aE-60
Viking model for mounting to a wall, post or Viking model gooseneck pedestal, EWPVE-5x5 VE-GNP
model recommended (not included, see ). DOD 424 WARNING: Do NOT use a typical “wet location
box” as not all styles seal properly with the faceplate.E-60
Features Overview
Rear (PCB) View of E-60
Push Button Switch: Push to
initiate call, push again to
disconnect. Solid 316 stainless
steel internally sealed per IP67.
Speaker Screen: Speaker
screen with 0.018" wide slots to
prevent punctures from
paperclips, etc.
Faceplate Material: 18 gauge
304 stainless steel. The SS model
has a #4 brushed finish, the BK,
BN and WH models have a
powder painted finish.
Speaker: Mylar speaker with
rubber gasket to maintain
water-tight seal and eliminate
water deterioration.
Mounting Screws: (4) 6-32 x
3/4" Marine grade 316 stainless
steel, flat head, 5/64" hexdrive
screws (included).
Blue Call LED: Lights steady to
help locate the button in low light,
flashes during dialing, then lights
steady when answered.
Microphone: Omni-directional
microphone with protective
water-resistant cloth.
Front View of the E-60
Faceplate Gasket: 1/8" thick
closed cell PVC to provide a
water-tight seal.
Earth Ground: To increase
surge protection, loosen the
screw labeled (as shown)
and fasten a wire with ring
terminal (included) from the
mounting screw to Earth
Ground (grounding rod,
water pipe, etc.)
Speaker Volume
Microphone Volume
Entry Phone Board:
Compact analog speaker
phone with call progress
detection for automatic
disconnect.
DIP Switches (see page 6):
1: Auto Answer Feature (on/off)
2: Dial Tone Detection (on/off)
3: Programming Switch
(normal/programming)
4: LED (on/off)
B. Old Work / Remodel Flush Mounting (Using an Allied Molded 9331 Rough-In Box)
C. Surface Mounting
D. Mounting the Faceplate
Step 1 .Make sure mounting location is free of wall studs, wires, etc.
Step 2
Place Rough-In box against siding. Trace outline of box onto siding. LEVEL Note: When mounting
to 4 inch or less horizontal lap siding, a siding mounting block can be used. Contact your siding
Installer for the correct mounting block part number. A siding mounting block is recommendedNote:
when mounting to vinyl siding.
Step 3 Cut a hole through the siding and wall sheathing just large enough for the rough-in box. Caution:
Too large of a hole can cause plate misalignment and compromise the gasket seal.
Step 4 The front surface of the Rough-In box can be mounted flush against wood siding or can be recessed
and mounted flush against wall sheathing when mounting on aluminum, steel or vinyl siding.
Step 5
When mounting to 5/8 inch thick or less wall sheathing the two attached screws with wing brackets
can be used to secure the rough-in box. When mounting to surfaces thicker than 5/8 inch, four
standard flat head dry wall screws can be used to secure the Rough-In box through its mounting
ears.
Step 6 To maintain a vapor barrier on outside wall applications, caulk around the box, filling any gaps
between the box and the rough opening. Apply caulk to any holes in the box around wires, etc.
A Viking model can be used to surface mount an to a wall, post or Viking model VE-5x5 E-60 VE-
GNP Gooseneck Pedestal (EWP model recommended), see for more information on theDOD 424
VE-5x5 and VE-GNP. Drill a small wire exit hole in wall. Pull wire through and seal hole around
wire with putty or caulking. Route wire into the box, securely screw it to wall or post andVE-5x5
seal hole in box around wire with putty or caulking. Attach (2) junction box to double gang adapter
plates (included with ) to top and bottom holes of the prior to mounting the E-60 VE-5x5 E-60. Note:
Conduit may also be used when surface mounting wire, but should not enter through the top of the
VE-5x5. When routing wiring from above, a drip loop is required. WARNING: Do NOT use a typical
“wet location box” as not all styles seal properly with the faceplate.E-60
After the Rough-In box or is securely mounted, caulking between the box and rough openingVE-5x5
is completed (if required), and wires are connected, remove paper liner from face plate gasket.
While firmly holding the LED light pipe in the faceplate, carefully slide the faceplate gasket over the
back of the light pipe and press gasket to the back of the faceplate. Push the 1-1/4" 6-32 screws
through faceplate holes and small holes in gasket, the faceplate gasket should retain the screws.
Position Circuit board mounting plate over screws. Align screws with single gang box bosses and
tighten face plate until gasket is fully collapsed and the push button is protruding through the
clearance hole in the face plate. Included 1/4" thick gasket will provide an adequate seal for most
siding surfaces; however for rough surfaces (ie: brick, stucco, etc.) additional caulking may be
required.
Circuit Board
Mounting Plate
(included)
1/4" Thick Foam
Faceplate Gasket
(included)
Facplate
(included)
(4) 6-32 x 1.25" Long
5/64" Hexdrive
Flathead Screws
(included)
"Old Work" Double Gang
Rough-In Box (Allied Molded
9312 box shown, not included)
(4) Optional Dry Wall
Screws (not included)
Optional VE-5x5 Surface Mount Box with black
satin powder paint finish, not included (DOD# 424).
Optional VE-LIGHT kit can be used to illuminate the
faceplate when used with a VE-5x5 (DOD# 428).
WARNING: Do NOT use a wet location box.
2.25”
5.14”
5.22” 3.25”
3.63”
3.63”
(2) Gel-Filled
Butt Co nnect o rs
(included)
Red
Gre e n
-OR-
(2) Junction Box to
Double Gang Adapter
Plates and (4) 5/64 Hex
Drive Flat Head Screws
(included with the E-60)
3.65"
Wide
Min.
2.84"
Tall Min.
*2.25"
Deep
Min. ** LED
Light Pipe
(included)
* CAUTION: Excessive wire length and/or using a rough-in box with inadequate depth can apply force to the
circuit board causing physical damage.
** Important: Push LED light pipe into faceplate hole, then place faceplate upside down on a clean flat surface
and push down on back side of plate until light pipe is fully seated and straight. WARNING: Inserting the
light pipe more than one time can cause a loose fit. 3


Produktspezifikationen

Marke: Viking
Kategorie: Gegensprechanlage
Modell: E-60-BN
Breite: 125.4 mm
Tiefe: 4.3 mm
Gewicht: 550 g
Produktfarbe: Bronze
Internationale Schutzart (IP-Code): IP67
Ăśbertragungstechnik: Kabelgebunden
Höhe: 123.8 mm
Platzierung: Wand
Betriebstemperatur: -34 - 65 °C
Zertifizierung: FCC Part 68\nFCC Part 15
Gehäusematerial: Edelstahl
Geräuschpegel: 62 dB
Abmessungen (BxTxH): 125.4 x 4.3 x 123.8 mm
Knopfanzahl: 1
Menge Außengeräte: 1
Inklusive Außengerät: Ja
Außengerät Stromversorgung: AC/DC
Einfache Installation: Ja
Autentifizierungstyp: Zugangschip/Karte

Brauchst du Hilfe?

Wenn Sie Hilfe mit Viking E-60-BN benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Gegensprechanlage Viking

Bedienungsanleitung Gegensprechanlage

Neueste Bedienungsanleitung fĂĽr -Kategorien-