ADDAC215 DUAL S&H+ USER’S GUIDE
October.2019Revision.02
Welcome to:
page 2ADDAC SYSTEM
OVERALL FEATURES
This module should not be judged by it’s size, at 6hp it’s packed with features.
At it’s core it features a noise source and two precision Sample & Holds with 0.01% of maximum devia-
tion from the Input which allows for quantized signals to be sent through without any noticeable detun-
ing or the typical over time voltage drop.
The Sample & Hold sections can also be used as a Track & Hold meaning it holds the incoming input
while the Trigger input is ON and lets the input flow to the output when the Trigger input is OFF.
Each section also features it’s own slew processor with a single control over attack/decay and an
ON/OFF switch.
The noise signal is normalled to both sections inputs, meaning that without a jack plugged into the Input
the sample and hold function will act upon the incoming noise signal generating random CV values.
The [Trigger A Alternate] switch allows to Link both sections so that any trigger input in Trigger A will
alternate between triggering the A and B section.
Besides each section output there’s also 4 extra outputs: Noise, Difference, Average and Sum. The [Noise]
output is coming from the noise source, the [Difference] output is the subtraction of section A minus
section B, the [Average] output is the sum of both A plus B and then divided by 2 and finally the [Sum]
output is the sum of both A plus B sections.
CONTROLS DESCRIPTION
ADDAC215 User’s Guide
page 3ADDAC SYSTEM
Section A SLEW
Set the Slew Decay ammount
applied to the S&H A signal
ALTERNATE/SEPARATE
Sets overall operating mode
Section A Trigger Input:
Any CV type is accepted Trigger/Gate/CV
(Normalled to Trigger B)
Section A Output
Section A Input
(Normalled to Input B)
Section (A-B) Diference Output
Section A SLEW switch
Sets the DECAY Slew On or Off
Section B SLEW switch
Sets the DECAY Slew On or Off
SAMPLE/TRACK & HOLD
Sets the operating mode of each
section
Section (A+B)/2 Average Output
Section B Trigger Input:
Any CV type is accepted Trigger/Gate/CV
Section B Output
Noise Output
Section B SLEW
Set the Slew Decay ammount
applied to the S&H B signal
SAMPLE/TRACK & HOLD
Sets the operating mode of each
section
Section B Input
Section (A+B) SUM Output


Produktspezifikationen

Marke: ADDAC System
Kategorie: Nicht kategorisiert
Modell: Dual S&H+ ADDAC215

Brauchst du Hilfe?

Wenn Sie Hilfe mit ADDAC System Dual S&H+ ADDAC215 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert ADDAC System

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-