Adastra RX45 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Adastra RX45 (11 Seiten) in der Kategorie Mischpult. Dieser Bedienungsanleitung war für 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/11
RX 45
ADVANCED AUDIO MATRIX
Item ref. RX45: 046953. UK
(optional) TR86: 953.0 UK 50
User Manual
Version 1.0
Caution: Please read this manual carefully before operating
Damage caused by misuse is not covered by the warranty
RX45 / TR86 User Manual
Introduction
Thank you for choosing the Adastra RX remote audio matrix system for your distributed audio installation. 45
This unit is designed to offer a flexible and expandable solution for a wide array of commercial sound systems.
Please read this manual to gain the best results from your product and avoid damage through misuse.
SAFETY SYMBOL AND MESSAGE CONVENTIONS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS
RISQUE DE CHOC ELECTRIQUE NE PAS
OUVRIR
This symbol indicates that dangerous voltage constituting a risk of electric shock is
present within this unit
This symbol indicates that there are important operating and maintenance instructions in
the literature accompanying this unit.
SAFETY NOTICE
1. Prior to use, read through this manual
2. Keep the manual in good condition
3. Pay attention to safety warnings
4. Observe all operating requirements
5. Do not use the device near water or wet areas
6. For cleaning, only use a lint-free, dry cloth
7. Install according to the specifications
8. Place away from heat sources or heating appliances
9. Use mains lead provided and avoid damage to cable or connectors
10. Unplug power from mains during stormy weather or if unused for long periods
11. In case of malfunction, wat ingress or other damage, consult qualified service personnel er
12. Do not place in damp areas or near liquids or moisture. Do not spill liquids on the housing
13. Please pay attention to warning symbols during transit and placement
14. Terminals marked with the sym l are HAZARDOUS LIVE and should only be connected by qualified personnel bo
15. Ensure that the apparatus is connected to a mains socket with a protective EARTH connection
16. Ensure correct operation of the mains switch
Warning
To prevent the risk of fire or ele ric shock, do not expose any components to rain or moisture. ct
If liquids are spilled on the casing, stop using immediately, allow unit to dry out and have checked by qualified personnel before
further use. Avoid impact, extreme pressure or heavy vibration to the case
No user serviceable parts inside Do not open the case refer all servicing to qualified service personnel. – –
Safety
Check for correct mains voltage and condition of IEC lead before connecting to power outlet
Placement
This unit can be use free- d standing or fixed into a 19” rack
Ensure adequate support and access to controls and connectors when rack-mounting
Cleaning
Use a soft cloth with a neutral detergent to clean the housing as required
Do not use strong solvents for cleaning the unit
RX45 / TR86 User Manual
Front panel
Rear panel
Connection
Connect outputs to each zone from the line level L+R RCA OUTPUTS on the rear panel ( 16)
Up to 3 stereo line level inputs can be connected to the RX45 via the rear panel L+R RCA LINE INPUTs (17)
(A further stereo 3.5mm AUX input is available on the front panel as a selectable source on the media player)
Ensure the Power (1) is switched off until all input and output connections are in place.
The zones of the RX45 can be controlled directly from the front panel or can also be remotely controlled by
connecting up to five optional 86 wall plates (ideal for local control from within each relevant zone). TR
TR86 wall plates are connected via RJ45 connectors on the rear panel with CAT5/6/7 cable to each TR86. (11)
Th RX45 can provide power to each wall plate up to 100m away. e
(adding external 24V power to the TR86 wall plate can extend this distance up to 1km)
For remote announcement to all or any of the 5 zones, an optional CS- call station (953.049UK) can be 5
added to the system. If a CS-5 call station is being used, connect this to the call station input ( ) on the rear 12
panel using network cable.
For announcements to all zones from the main RX45 unit, a paging microphone input is provided on the front
or rear panel (2 1) If the paging microphone requires phantom power (e.g. condenser mic), enable this by , 2 .
selecting the phantom power DIP switch ( ) to 20 “ ”ON .
If DAB+ or FM radio is to be used connec, t a DAB+/FM antenna to the rear panel F‘ ’ socket ( 10)
24V MUTE CONTACTS (14) can be connected to the 24V trigger of alarm system panel to mute playback. an
If line level siren or alert signal is available, this can be connected to the EMG AUDIO terminals a IN (15).
When all other connections are made, connect the mains power to the IEC inlet (22) using the supplied lead.
1.
Mains power on/off switch
6
Output zones selectors & indicators
2.
Paging microphone input (XLR)
7.
Selected zone edit section
3.
Page on/off button
8.
Headphones output & volume control
4.
Paging microphone level
9.
Media player section
5.
MIC & EMG/MUTE dicators in
10.
DAB+/FM antenna connection (F-type)
17.
Line input level controls
11.
TR86 remote control inputs (RJ45)
18.
Line inputs 1, 2, 3 (L+R RCA)
12.
CS- call station input (RJ45) 5
19.
Cascade links (2 x RJ45 in, 2 x RJ out) 45
13.
Group ID set DIP switches
20.
Media player assign & phantom DIP switches
14.
24Vdc emergency mute contacts
21.
Paging microphone rear input (XLR)
15.
Emergency audio line input contacts
22.
Mains power inlet (IEC) with fuse holder
16.
Zone line outputs (L+R RCA)


Produktspezifikationen

Marke: Adastra
Kategorie: Mischpult
Modell: RX45

Brauchst du Hilfe?

Wenn Sie Hilfe mit Adastra RX45 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Mischpult Adastra

Bedienungsanleitung Mischpult

Neueste Bedienungsanleitung für -Kategorien-