Thank you for choosing Adastra mic/line mixer as part of your sound reinforcement system. an ML
This unit is designed to offer high quality, dependable service for audio mixing and distribution .
Please read this manual to gain the best results from your product and avoid damage through misuse.
SAFETY SYMBOL AND MESSAGE CONVENTIONS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS
RISQUE DE CHOC ELECTRIQUE NE PAS
OUVRIR
This symbol indicates that dangerous voltage constituting a risk of electric shock is
present within this unit
This symbol indicates that there are important operating and maintenance instructions in
the literature accompanying this unit.
SAFETY NOTICE
1. Prior to use, read through this manual
2. Keep the manual in good condition
3. Pay attention to safety warnings
4. Observe all operating requirements
5. Do not use the device near water or wet areas
6. For cleaning, only use a lint-free, dry cloth
7. Install according to the specifications
8. Place away from heat sources or heating appliances
9. Use mains lead provided and avoid damage to cable or connectors
10. Unplug power from mains during stormy weather or if unused for long periods
11. In case of malfunction, water ingress or other damage, consult qualified service personnel
12. Do not place in damp areas or near liquids or moisture. Do not spill liquids on the housing
13. Please pay attention to warning symbols during transit and placement
14. Terminals marked with the symbol are HAZARDOUS LIVE and should only be connected by qualified personnel
15. Ensure that the apparatus is connected to a mains socket with a protective EARTH connection
16. Ensure correct operation of the mains switch
Warning
To prevent the risk of fire or electric shock, do not expose any components to rain or moisture.
If liquids are spilled on the casing, stop using immediately, allow unit to dry out and have checked by qualified personnel before
further use. Avoid impact, extreme pressure or heavy vibration to the case
No user serviceable parts inside Do not open the case refer all servicing to qualified service personnel. – –
Safety
• Check for correct mains voltage and condition of IEC lead before connecting to power outlet
Placement
• This unit can be used free-standing or fixed into a 19” rack
• Ensure adequate support and access to controls and connectors when rack-mounting
Cleaning
• Use a soft cloth with a neutral detergent to clean the housing as required
• Use a vacuum cleaner to clear ventilation grilles of any dust or debris build-ups
• Do not use strong solvents for cleaning the unit
953.026 User Manual UK
Front panel
Rear panel
Connection
Ensure the Power (6) is switched off until all input and output connections are in place.
Turn all rotary level controls (1,2,4) fully down (anti-clockwise) to avoid loud noises when switching on.
Set t and TREBLE Tone controls (3) to the vertical position (zero) he BASS
Connect microphones to the balanced XLR inputs on the rear panel (14).
For microphone inputs, set the Mic/Line DIP switch (13) to “MIC”
Where condenser microphones are used which require phant om power, set the PHANTOM DIP switch to “ON”
Alternatively, mono line inputs can be connected to any of the XLR inputs by setting this DIP switch to “LINE”
Stereo line level sources can be connected to AUX1 and AUX2 RCA inputs (12)
A recording output is ovided on 2 RCA connectors (11), which is not governed by the MASTER level (4) pr
This can be connected to recording equipment or be used as an additional main output if required.
Main output is available via left and right balanced XLR sockets (9) and mono unbalanced 6.3mm jack (10)
Use any or all of these outputs to connect to the amplifier(s) or active speakers as required for the system.
Connect the rear IEC inlet (7) to the mains using the supplied mains lead (or an equivalent approved type).
Ensure th the supply voltage is correct for this equipment and that the mains outlet is switched on. at
For mobile operation or away from mains supply, a 24Vdc input is provided on screw terminals (8).
Make sure the power switch is turned off before connecting to a 24Vdc power source and observe correct
polarity before powering up the unit on DC power.
1.
Mic/Line inputs 1-6 Level controls
4.
Master volume control
2.
Aux 1 + Aux 2 Level controls
5.
L+R output meters
3.
Global Tone controls
6.
Power on/off switch and indicator
7.
Mains inlet IEC fuse holder and
12.
Aux 1 + Aux 2 RCA line inputs (L+R)
8.
24Vdc power contacts
13.
Mic/Line & Phantom Power DIP switches
9.
Left + Right XLR balanced outputs
14.
Mic/Line channel 1 - 6 balanced XLR inputs
10.
Mono 6.3mm unbalanced jack output
15.
CH.1 Override level control
11.
RCA Recording outputs (L+R)