Zalman ZM750-EBT Bedienungsanleitung

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Zalman ZM750-EBT (44 Seiten) in der Kategorie Computervoeding. Dieser Bedienungsanleitung war für 8 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/44
User's Manual
www.ZALMAN.com
※ To ensure safe and easy installation, Please read the following precautions.
Ver.180112
EBT Series
High Efciency Switching
Power Supply
11
Power Supply
AC Power Cord
Four Screws Five Cable Ties
User's Manual
1. Warnings and Safety Precautions
2. Components
Opening the cover of the product while the power cord is plugged into an outlet
may cause electrocution or critical damage to the product.
Handling the power cord with wet hands may cause electrocution.
▶ Inserting 󰘰ngers or metallic objects into the cooling fan may cause injury or
electrocution.
Operating the product in an extremely cold or hot environment can degrade
product performance and lifespan.
Exposure to liquids may cause malfunction.
▶ Operation in a humid or non-ventilated environment may reduce product lifespan.
▶ Plugging the main power connector P1 into the motherboard while the product is
connected to the AC power source may cause damage to the motherboard.
Make sure that the connectors are connected to their designated locations, and
that the connectors are not oriented in the wrong direction when connecting the
DC output connectors.
▶ Please use gloves to prevent injuries during installation.
Product designs and speci󰘰cations may be revised without prior noti󰘰cation to
improve quality and performance.
Neglecting the following may cause serious injury or death.
Neglecting the following may cause minor injuries, degrade product
conditions or cause malfunction.
Caution
Warning
Disclaimer) Zalman Tech Co., Ltd. is not responsible for any damages due to external
causes, including but not limited to, improper use, problems with electrical
power, accident, neglect, alteration, repair, improper installation, or
improper testing.
English
2
3. Speci󰘰cations
1) ZM650-EBT Electrical & Physical Speci󰘰cations
AC Input Range Voltage 100~240VAC
±10%
Vout
Output Load Rating Combined
Power
Frequency 50Hz ~ 60㎐
±3 Imin Imax Ipeak
AC Input Current
100VAC
10A +3.3V 0.0A 22A
120W
650W
240VAC +5V 22A0.0A
PFC Type Active PFC 0.0A 54.2A 650W+12V
Power Factor Correction Max 99% -12V 0.0A 0.3A 3.6W
Inrush Current Limit
(@ Cold Start at 25℃)
100VAC
Max 150A +5VSB 0.0A 15W3A
240VAC Ambient Temperature
E󰘲ciency Max 92% @ 230VAC, Typical load Operation 0 ~ +40℃
DC Output Voltage
Regulation
Vout Regulation Range
At
Full
Load
Storage -20 ~ +70℃
+3.3VDC +3.14 ~ +3.47V Ambient Humidity±5%
+5VDC ±5% +4.75 ~ +5.25V Operation 5% ~ 95% RH
+12VDC ±5% +11.4 ~ +12.6V Storage 5% ~ 95% RH
-12VDC -10.8 ~ -13.0V Dimensions 160(D) x 150(W) x 86(H)mm±10%
+5VSB +4.75 ~ +5.25V Weight 2.4kg±5%
DC Output Ripple
& Noise
Vout Standard Range
At
Full
Load
Protection Funtions
+3.3VDC Over-Current Protection (OCP)50mV
+5VDC 50mV Over-Voltage Protection (OVP)
+12VDC 120mV Under-Voltage Protection (UVP)
-12VDC Short-Circuit Protection (SCP)120mV
+5VSB Over-Power Protection (OPP)50mV
Over-Temperature Protection (OTP)
2) ZM750-EBT Electrical & Physical Speci󰘰cations
AC Input Range Voltage 100~240VAC
±10%
Vout
Output Load Rating Combined
Power
Frequency 50Hz ~ 60㎐
±3 Imin I
max I
peak
AC Input Current
100VAC
10A +3.3V 0.0A 22A
120W
750W
240VAC +5V 22A0.0A
PFC Type Active PFC 0.0A 62.5A 750W+12V
Power Factor Correction Max 99% -12V 0.0A 0.3A 3.6W
Inrush Current Limit
(@ Cold Start at 25℃)
100VAC
Max 150A +5VSB 0.0A 15W3A
240VAC Ambient Temperature
E󰘲ciency Max 92% @ 230VAC, Typical load Operation 0 ~ +40℃
DC Output Voltage
Regulation
Vout Regulation Range
At
Full
Load
Storage -20 ~ +70℃
+3.3VDC +3.14 ~ +3.47V Ambient Humidity±5%
+5VDC ±5% +4.75 ~ +5.25V Operation 5% ~ 95% RH
+12VDC ±5% +11.4 ~ +12.6V Storage 5% ~ 95% RH
-12VDC -10.8 ~ -13.0V Dimensions 160(D) x 150(W) x 86(H)mm±10%
+5VSB +4.75 ~ +5.25V Weight 2.5kg±5%
DC Output Ripple
& Noise
Vout Standard Range
At
Full
Load
Protection Funtions
+3.3VDC Over-Current Protection (OCP)50mV
+5VDC 50mV Over-Voltage Protection (OVP)
+12VDC 120mV Under-Voltage Protection (UVP)
-12VDC Short-Circuit Protection (SCP)120mV
+5VSB Over-Power Protection (OPP)50mV
Over-Temperature Protection (OTP)
English

Produktspezifikationen

Marke: Zalman
Kategorie: Computervoeding
Modell: ZM750-EBT

Brauchst du Hilfe?

Wenn Sie Hilfe mit Zalman ZM750-EBT benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Computervoeding Zalman

Bedienungsanleitung Computervoeding

Neueste Bedienungsanleitung für -Kategorien-