Yamato DKS-3002 Bedienungsanleitung

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Yamato DKS-3002 (4 Seiten) in der Kategorie niet gecategoriseerd. Dieser Bedienungsanleitung war für 6 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
DKS-3002 Operation ManualDKS-3002 Operation Manual
DIGITAL SCALES
YCO-1039-02-02
YAMATO CORPORATION
1775 S. Murray Blvd.
Colorado Springs, CO 80916 USA
Tel (719) 591-1500 Fax (719) 591-1045
YAMATO TECH CORPORATION
#112-19425 Langley By-Pass
Surrey, B.C. V3S 6K1 Canada
Tel (604) 533-2338 Fax (604) 533-0827
www.YamatoCorp.com
NOTES
YCO-1039-02-02
8
WEIG
HT
4
lb x 0 .1 o z
-
0
~
1000 g x 1 g 1 00 0 ~ 2
000 g
x 2
g
lb
g
lb oz
DKS-3002 Operation ManualDKS-3002 Operation Manual
INSTRUCTIONS FOR USE
POWER
The DKS-3002 can be powered by a 9 volt alkaline transistor
battery or by an optional AC adaptor. Plug the AC adaptor
into a wall outlet and insert the plug into the jack in the back
of the scale, or remove the cover on the underside of the
scale and push the connector firmly onto the battery termi-
nals. Replace the cover.
TO SWITCH ON
Place the scale on a flat, stable surface. Press the ON/ZERO
key once (quite firmly) in the center. The display will show
"8888" and then "0.0".
CLEANING AND CARE
• If the scale is not being used for a long period of time, re-
move the battery. Remove dead batteries immediately.
• Clean the scale with a damp cloth, do not immerse the scale
in water, or use chemical or abrasive cleaning agents.
• All plastic parts should be cleaned immediately after contact
with fats, spices, vinegar, or strongly flavored or colored
foods. Avoid contact with acids such as citrus fruit juices.
• Avoid placing your scale directly next to a microwave oven if
both will be used at the same time. Some microwave ovens
emit interference which, at close range, can cause the dis-
play of the scale to fluctuate.
TECHNICAL SPECIFICATIONS
Power Supply:
One alkaline 9 V battery or an optional AC adaptor
Capacities and Divisions
0 lb to 4 lb x 0.1 oz
0 g to 1 kg x 1 g and 1 kg to 2 kg x 2 g
Accuracy:
To within +/- one increment or 1% of applied load
Maximum Tare:
15.9 oz or 999 g
Dimensions:
Scale - 6 5/8" x 5 7/8" x 1 1/2"
Platform - 4 3/4" x 5 7/8"
27
DKS-3002 Operation ManualDKS-3002 Operation Manual
MINOR TROUBLE SHOOTING
1. Is the scale level?
Make sure that all the feet are resting firmly on the supporting
surface and that the surface is level.
2. Is the scale turned on?
If the scale does not work at all, depress the ON/Zero key.
Repeat once or twice. The scale will automatically turn off if
not used for two minutes (thirty seconds with a zero reading)
to preserve battery life.
3. "Err" indication?
When the weight of the scale platform exceeds 105% of the
capacity of the scale, "Err" will appear on the digital display,
Reduce the load.
4. Is movement of the scale platform restricted in any way?
Make sure that no foreign objects are wedged between the
platform and the scale body. Verify that the platform is not
rubbing against any surrounding objects.
5. "Lo" indication?
Remove the battery cover and install a new 9 volt alkaline
battery.
If these actions fail to correct the problem, the scale needs to
be serviced by a qualified technician.
INSTRUCTIONS FOR USE
TO SELECT WEIGHT UNITS
Press the LB/G key to convert between kg-g and lb-oz units.
This can be done at any time during weighing.
36

Produktspezifikationen

Marke: Yamato
Kategorie: niet gecategoriseerd
Modell: DKS-3002

Brauchst du Hilfe?

Wenn Sie Hilfe mit Yamato DKS-3002 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung niet gecategoriseerd Yamato

Bedienungsanleitung niet gecategoriseerd

Neueste Bedienungsanleitung für -Kategorien-