Wolf ACB60 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Wolf ACB60 (36 Seiten) in der Kategorie Grillplatte. Dieser Bedienungsanleitung war für 9 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/36
©ITW Food Equipment Group, LLC
3600 North Point Blvd.
Baltimore, MD 21222
RETAIN THIS MANUAL FOR FUTURE USE
FORM F38328 (9- ) 15
INSTALLATION & OPERATION MANUAL
GAS CHARBROILERS
MODELS
VACB25
VACB36
VACB47
VACB60
VACB72
ACB25
ACB36
ACB47
ACB60
ACB72
VACB36
ACB36
For additional information on Vulcan or to locate an authorized parts and
service provider in your area, visit our website at www.vulcanequipment.com
- - 2
IMPORTANT FOR YOUR SAFETY
THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO
INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD
START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS
MANUAL.
POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN
THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE
OBTAINED FROM THE LOCAL GAS SUPPLIER.
IMPORTANT
IN THE EVENT A GAS ODOR IS DETECTED, SHUT
DOWN UNITS AT MAIN SHUTOFF VALVE AND
CONTACT THE LOCAL GAS COMPANY OR GAS
SUPPLIER FOR SERVICE.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER APPLIANCE.
IN THE EVENT OF A POWER FAILURE, DO NOT ATTEMPT TO OPERATE THIS DEVICE.
Improper installation,
adjustment, alteration, service or maintenance
can cause property damage, injury, or death.
Read the installation, operating and maintenance
instructions thoroughly before installing or
servicing this equipment.
- - 3
INSTALLATION, OPERATION AND CARE OF
GAS COUNTERTOP CHARBROILERS
GENERAL
Vulcan/Wolf Gas Countertop Charbroilers are designed for commercial use only and
feature fast, efficient gas heat. Each burner is controlled by an adjustable gas valve.
Cast radiants are located directly above each burner to maintain unif orm temperature.
Radiants are easily removed for cleaning when cool.
Heavy-duty cast iron top grates are reversible to allow all or part of the cook ing grid
surface to be level or sloped . A crumb tray is provided to collect fat run -off and debr is;
it opens to the f ront for inspection or cleaning .
Number of Bu rners
Natu ral G as BT U/hr
In put Rat ing
LP G as BT U/hr
Input Rating
4
68 ,000
64 ,000
6
10 2,000
96 ,000
8
13 6,000
12 8,000
11
18 7,000
17 6,000
13
22 1,000
20 8,000
INSTALLATION
UNP AC KING
This charbroiler was inspected before leaving the factory. The carrier assumes full responsibility for the
safe delivery upon acceptance of the shipment. Check for possible shipping damage immediately after
receipt.
If the charbroiler is found to be damaged, complete the following steps:
1. Carrier must be notied within 5 business days of receipt.
2. Carrier’s local terminal must be notified immediately upon discovery (note time, date, and
who was spoken to), and follow up and conrm with written or electronic communication.
3. All original packing materials must be kept for inspection purposes.
4. The charbroiler cannot have been moved, installed, or modied.
5. Notify Vulcan Customer Service immediately at 800- -2028. 814
Carefully unpack your charbroiler and m ake sure that no parts are di scarded with
pack aging material. A pressure regulator designed to operate with the broiler has been
supplied and must be installed before the charbroiler is place d into service (Refer to GAS
PRESSURE REGULATOR INSTALLATION in this manual).