User Manual Digital Thermometers
English
Safety warnings Page 13
Technical specifications Page 14
Description of instrument Page 15
Electrical connections Page 15
Operation Page 15
Setting the parameters Page 16
Parameter menu Page 17
Error messages Page 19
Reference standards Page 19
Dimensions and connection diagrams 33x75 mm Pages 20-21
Dimensions and connection diagrams 72x72 mm Pages 22-23
CONTENTS
During the installation and operation of the instrument, the
following instructions should be adhered to:
1) The instrument should be installed by a skilled person.
2) Always follow the connection diagrams closely to install the
instrument.
3) Do not power or connect the instrument if any part of it is
damaged.
4) Before touching the terminals, make sure the wires to be
connected to the instrument are not live.
5) The connection cables should be able to resist the maximum
operating temperature (Tmax), obtained from the sum of the
maximum ambient temperature (Ta) + a temperature of 20 °C
(Tmax= Ta + 20 °C)
6) The instruments guarantee main insulation between the low
voltage parts (250 V) and the very low voltage parts.
7) Any external switches connected to the control should guarantee
a minimum insulation at the operating temperature of 250 V AC
or should be protected by an equivalent insulation.
8) The instruments require no maintenance.
SAFETY WARNINGS
- 14 -
User Manual Digital Thermometers
English
TM series of digital thermometers for the measurement and display of the
temperature using thermocouple or thermal resistance probes.
Three dedicated models for probe input:
- P T CThermal resistance PTC ( ositive emperature oefficent) - Ni, Pt
model TM NiPt
- N T CThermal resistance NTC ( egative emperature oefficent)
model TM NTC
- Thermocouples TC - J, K, L, R, S, T, E, N
model TM JK
Setting of programming probes.
Two probe inputs for model TM -P3D - for the measurement of two NTC
temperatures that can be displayed either through the closure or opening
of an outside consensus to be connected to the instrument.
Thermometers with led 3 digit, seven segment and decimal point
display 3 (excluding the model TM -P7A, with 4 digits and maximum JK
display of +1600 °C).
Display range: -99 ÷ +999 °C (excluding model TM -P7A, with 4 digits andJK
display range -99 ÷ +1600 °C).
Display resolution: 0.1 °C (-9.9 ÷ +99.9 °C)
e 1 °C (< -9.9 °C e > +99.9 °C).
Precision: ±0.5 % of the end of scale value ±1 digit (at ambient T 23 °C).
Sampling time: 0.5s.
Possibility of displaying the minimum and maximum temperature.
Possibility of varying the probe calibration offset.
Possibility of varying the temperature measurement unit
between °C and °F.
TECHNICAL SPECIFICATIONS
Possibility of varying the update speed for the display of the measurement.
Possibility of entering an access password for the protection of
the settings.
Acoustic and visual alarm warning due to probe malfunction or sensor cable
disconnected.
Infrared receiver with RC-5 protocol (models TM NiPt - ..P3..
and TM JK - ..P3... only) for remote control (accessory available separately for
remote programming).
Available in 33x75 mm and 72x72 mm rear panel versions.
Power supply: see table on the following page.
Rated power: 3 VA for the 33x75 models.
4.5 VA for the 72x72 models.
Max absorption: 100 mA at 12 V - 50 mA at 24 V.
Operating temperature: 0 ÷ +50 °C.
Operating humidity: <80%.
Storage temperature: -10 ÷ +70 °C (<80% RH).
Protection level: front panel IP54
terminals IP20
- 15 -
User Manual Digital Thermometers
English
In model TM -P3D, the display of the second temperature is NTC
indicated by the led at the position of the marking T2.
Keys
There are three parameter setting keys:
Parameter confirm and programming/display key.
Parameter increase key or movement to the next parameter.
Parameter decrease or exit menu key.
Adhere strictly to the safety warnings and the instructions in the
connection “diagram section”.
Normal operation
This operation is obtained outside the parameter programming mode.
In this status, the instrument takes the measurement on the basis of the
parameters set. The information displayed is as follows:
OPERATION
ELECTRICAL CONNECTIONS
OK
Rear panel 33x75 mm
Code Model Power supply (*) Probe Digital Infrared
inputs input receiver
VM620200 TM NiPt-P3D from 12 to 24 V AC/DC
50/60 Hz 1 NO YES
VM622800 TM NTC-P3D from 12 to 24 V AC/DC
50/60 Hz 2 YES NO
VM624400 TM JK-P3D from 12 to 24 V AC/DC
50/60 Hz 1 NO YES
Rear panel 72x72 mm
Code Model Power supply (*) Probe Digital Infrared
inputs input receiver
VM619400 TM NiPt-P7A 24/230 V AC 50/60 Hz 1 NO NO
VM621000 TM NTC-P7A 24/230 V AC 50/60 Hz 1 NO NO
VM623600 TM JK-P7A 24/230 V AC 50/60 Hz 1 NO NO
* Power supply voltage tolerance ± 10%
Display
3 digit led display with decimal point, with the exception of
model TM JK-P7A, with 4 digit led display.
For all the models, the display range is:
- minimum display: -99 °C or -9.9 °C
- maximum display: +999 °C (+1600 °C for model TM JK-P7A )
or +99.9 °C
DESCRIPTION OF INSTRUMENT

Produktspezifikationen

Marke: Vemer
Kategorie: Thermometer
Modell: TM NiPt-P3D

Brauchst du Hilfe?

Wenn Sie Hilfe mit Vemer TM NiPt-P3D benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Thermometer Vemer

Bedienungsanleitung Thermometer

Neueste Bedienungsanleitung für -Kategorien-