Velleman VTBAL6 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Velleman VTBAL6 (16 Seiten) in der Kategorie Küchenwaage. Dieser Bedienungsanleitung war für 18 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/16
VTBAL6
COUNTING SCALES
TELWEEGSCHAAL
BALANCE DE COMPTAGE
BALANZA CUENTAPIEZAS
ZÄHLWAAGE
USER MANUAL
GEBRUIKERSHANDLEIDING
NOTICE D’EMPLOI
MANUAL DEL USUARIO
BEDIENUNGSHANDLEITUNG
VTBAL6_v3 VELLEMAN
2
VTBAL6 – COUNTING SCALES
1. Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment.
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling.
This device should be returned to your distributor or to a local recycling service.
Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Velleman! Please read the manual thoroughly before bringing this device into service. If the device was damaged in
transit, do not install or use it and contact your dealer.
2. Technical Specifications
Capacity 5kg/12lb
Display Resolution 6.0000kg x 0.0005kg/13.2280lb x 0.0010lb
Counting Range 0 ~ 16777216
Tare Range 0 ~ 100% FS
Zero Range power-on zero range ± 5% FS
Min. Input Piece Weight 0.5g/0.0002lb
Operating Temperature 15°C ~ 35°C
Power Supply 220VAC/12VDC PSU + internal 6V/4Ah rechargeable battery (both incl.)
Power Consumption < 120mA at lowest brightness setting (200mA at default setting)
Dimensions 110 x 290 x 330mm
Spare PSU order code PS1205R
Spare Battery order code WP4-6
Unit Conversion 1lb = 0.45359237kg, 1kg = 2.20462262lb
3. Setting up Your Scales
Place the scales on a stable and horizontal surface where it is out of the sunlight and protected against extreme temperatures and
temperature changes, humidity, fumes, dust, draughts and electromagnetic fields. Turn the adjustable feet until the scales are level.
Insert the battery into the scales minding the polarity. Connect the scales to the PSU and insert the PSU into the mains.
4. Operation
4.1. Key Description
Numeric keypad
Clear the entered data (in input mode) or exit input mode after
clearing data
Confirm and save the entered data (in input mode) or confirm
operation (all other modes)
Zero the scales – range is power-on zero point ± 5% - proper
power-on zero point is calibration zero point ± 10% of FS
Tare function – tare range is 0 ~ 100% of FS
Totalising function
Choose the current weighing unit (kg or lb) or piece weighing unit
(g or lb)
Input the piece weight
Input the upper limit
Input the lower limit
On/off key or exit key when in auto off setting mode and calibration
mode
VTBAL6_v3 VELLEMAN
3
4.2. Setting the Display’s Brightness
Switch on the scales.
Hold both and keys pressed to enter the setup mode.
Set the brightness using numeric key , or (brightness settings from low to high with setting as default setting). 2
Press to confirm your choice.
4.3. Selecting the Weight Unit
Switch on the scales.
Press to select your weight unit (g or lb). The corresponding LED will light.
4.4. Normal Weighing
Switch on the scales.
Place the object (or objects) onto the weighing platform. The WEIGHT window will display a number.
4.5. Totalising Function
4.5.1. How to Determine the Tare Weight
Switch on the scales.
Place the tare weight (usually a box or a tray) onto the weighing platform. The WEIGHT window will display a number.
Press to tare the object. The WEIGHT window will return to a 0.0000 display and the TARE LED will light.
Remove the tare object from the weighing platform. Note that the tare weight is now preceded by a minus sign.
Note: Press to erase the tare value. The tare weight will be cancelled when switching off the scales.
4.5.2. How to Determine the Piece Weight
Press to enter the mode.
Place the object (or objects) onto the weighing platform or in the container. The WEIGHT window will display a number.
Enter the weight manually in the PIECE WEIGHT window using the numeric keys. Confirm the value with .
4.5.3. How to Determine the Piece Quantity
When the piece weight is determined, determine the quantity using the numeric keys. The entered quantity will be displayed in the
COUNT window.
Confirm the value with .
4.5.4. How to Determine the Upper and Lower Limits
Press and enter the upper limit using the numeric keys.
Press and enter the lower limit using the numeric keys.
Place the object or objects onto the weighing platform or in the container. The WEIGHT and the COUNT windows will each display a
number. The scales will sound if the displayed number is within the limit range.
Note: Make sure to respect following formula when determining the limits: upper limit lower limit > 0.
4.5.5. How to Totalise
Press to add the weight into the memory. The scales can totalise up to 999,999 values for a total weight value of 16,777,215.
Press to clear the memory.


Produktspezifikationen

Marke: Velleman
Kategorie: Küchenwaage
Modell: VTBAL6
Display-Typ: LED
Produktfarbe: Grey, Silver
Höchstgewichtskapazität: 6 kg
Typ: Elektronische Küchenwaage
Abmessungen (BxTxH): 330 x 290 x 110 mm
Rutschfeste Füße: Ja
Genauigkeit: 0.5 g
Kapazität: 6 kg

Brauchst du Hilfe?

Wenn Sie Hilfe mit Velleman VTBAL6 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Küchenwaage Velleman

Bedienungsanleitung Küchenwaage

Neueste Bedienungsanleitung für -Kategorien-