Uni-T UT575B Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Uni-T UT575B (31 Seiten) in der Kategorie Messung. Dieser Bedienungsanleitung war für 4 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/31
DOUBLE CLAMP MULTIFUNCTIONAL EARTH TESTER
Contents
I. Safety Information ....................................................................................................... 1
II. Introduction ................................................................................................................. 2
III. Technical Specifications .............................................................................................. 3
1) Benchmark and Working Conditions ........................................................ 3
2) General Specifications ............................................................................. 3
3) Basic Errors and Performance Specifications under Benchmark
Conditions ............................................................................................... 6
IV. III. Tester Structures ................................................................................................... 7
V. IV. Functional Knob 9 ....................................................................................................
VI. V. LCD Display ........................................................................................................ 10
VII. VI.Measurement Rationales ...................................................................................... 11
VIII. VII.Operating Instructions .......................................................................................... 15
1) Power On/Off ......................................................................................... 15
2) Check the Battery Voltage...................................................................... 15
3) -Simple 2 Wire Method 15 ...........................................................................
4) 3-Wire Method ....................................................................................... 16
5) 4- Wire Precision Method........................................................................ 17
6) 4-Wire Selection Method ........................................................................ 19
7) Single- -Clamp 3 Wire Selection Method .................................................. 21
8) Double- Clamp Method........................................................................... 21
9) Soil Resistivity Testing ........................................................................... 22
10) DC Resistance Testing ........................................................................... 24
11) AC Current Testing ................................................................................ 25
12) Grounding Voltage Testing ..................................................................... 25
13) Backlight Control 26 ...................................................................................
14) Alarm Setting ......................................................................................... 27
15) Data Hold/Storage ................................................................................. 27
16) Data Viewing/Deletion ............................................................................ 27
17) Data Uploading ...................................................................................... 28
IX. VIII.Battery Charging ................................................................................................. 28
X. IX.Packing List .......................................................................................................... 29
1
Safety Information
Thank you for buying this product, for better use of it, please be sure of the followings:
Read the user manual carefully.
Follow all operating precautions in the user manual.
The tester is designed, manufactured and inspected according to IEC61010 safety
standard.
Pay special attention to safety use in any case.
The USB port is not isolated with internal circuit, it is forbidden to connect with computer
during voltage testing. Otherwise it will cause tester damage or electric shock. Before
connecting USB cable with the computer to read data, please disconnect the voltage test lead
with the tester.
-The on line monitoring mentioned in the user manual is applicable to voltage monitoring.
Please pay attention to the text and symbol on the label at the tester.
Pay attention to the current direction of the current clamp when performing grounding
resistanc e test.
Please make sure that the tester and its accessories are intact. If the insulations of the
tester and test lead are damaged, or the lead is bare or broken, please do not use!
It is forbidden to make contact with the bare conductor and the circuit under
measurement.
Please set the functional knob at corresponding position before measurement.
Make sure that the plug of the test lead is well connected with the port of the tester.
Do not apply grounding voltage over 100V between the test end and the port, otherwise
the tester may be damaged.
Do not perform measurement in inflammable places, the spark may cause explosion.
If exposed metal occurs due to crack of the casing or test lead during use, please stop
using immediately.
Do not place and keep the tester in places with high temperature, high humidity, dews
and direct sunlight for an extended period of time.
Please make sure the tester is dry before storing it.
Remove the test lead from the tester and set the functional knob at “OFF” position
before replacing the battery.
Please charge the tester in time if the low battery symbol “ ” is displayed.
If the tester is not used for an extended period of time, please charge the tester once
every one or two months to avoid battery damage.
Use, disassembly, calibration and repair must be performed by authorized eligible
Produktspezifikationen
Marke: | Uni-T |
Kategorie: | Messung |
Modell: | UT575B |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Uni-T UT575B benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Messung Uni-T
11 Juni 2024
11 Juni 2024
23 Mai 2024
19 Mai 2024
19 Mai 2024
15 Mai 2024
5 Mai 2024
2 Mai 2024
21 April 2024
20 April 2024
Bedienungsanleitung Messung
- Messung Hama
- Messung REV
- Messung Voltcraft
- Messung Bosch
- Messung Laserliner
- Messung Velleman
- Messung Powerfix
- Messung Alecto
- Messung Beurer
- Messung Bresser
- Messung König
- Messung TFA
- Messung Black And Decker
- Messung Trotec
- Messung DeWalt
- Messung Pioneer
- Messung Megasat
- Messung Smartwares
- Messung Garmin
- Messung GOCLEVER
- Messung Perel
- Messung Workzone
- Messung Microlife
- Messung Rossmax
- Messung Amprobe
- Messung Meec Tools
- Messung Metrix
- Messung IHealth
- Messung Ansmann
- Messung Westfalia
- Messung Livington
- Messung Silverline
- Messung Yato
- Messung Be Cool
- Messung Toolland
- Messung AS Schwabe
- Messung Hager
- Messung Kyoritsu
- Messung Eurolite
- Messung GW Instek
- Messung KERN
- Messung Milwaukee
- Messung Eizo
- Messung Testo
- Messung Victron Energy
- Messung Peak
- Messung Kübler
- Messung Carrier
- Messung Lund
- Messung SHX
- Messung Gima
- Messung Testboy
- Messung Danfoss
- Messung Fantini Cosmi
- Messung Multimetrix
- Messung Extech
- Messung BENNING
- Messung Fluke
- Messung FLIR
- Messung Vemer
- Messung Oregon Scientific
- Messung Ridgid
- Messung Stabila
- Messung Hikmicro
- Messung Entes
- Messung Gossen Metrawatt
- Messung Hameg
- Messung Joy-it
- Messung Megger
- Messung Muller
- Messung PCE Instruments
- Messung RK Technology
- Messung Sanwa
- Messung Sonel
- Messung VirtuFit
- Messung Wachendorff
- Messung TFA Dostmann
- Messung Vimar
- Messung Owon
- Messung PeakTech
- Messung Comark
- Messung Dahua Technology
- Messung YSI
- Messung Aluratek
- Messung SRS
- Messung Eltako
- Messung H-Tronic
- Messung HT Instruments
- Messung Beha-Amprobe
- Messung Chauvin Arnoux
- Messung Werma
- Messung Eastron
- Messung Emko
- Messung Pancontrol
- Messung X-Rite
- Messung CESYS
- Messung Trumeter
- Messung Kemo
- Messung ORNO
- Messung Tempest
- Messung TDE Instruments
- Messung Zircon
- Messung Kreg
- Messung Apollo Ultrasonic
- Messung BJZ
- Messung Adwa
- Messung Greisinger
- Messung Qubino
- Messung Beckmann & Egle
- Messung Weidmüller
- Messung Janitza
- Messung CEM
- Messung Klein Tools
- Messung Daytronic
- Messung AREXX
- Messung Delta Ohm
- Messung Camille Bauer
- Messung Rigel Medical
- Messung UHoo
- Messung Seaward
- Messung AstroAI
- Messung P3 International
- Messung Seek Thermal
- Messung ClimeMET
- Messung Fixpoint
- Messung Condtrol
- Messung Cliff
- Messung Water-i.d.
- Messung Stahlwille
- Messung KS Tools
- Messung AkYtec
Neueste Bedienungsanleitung für -Kategorien-
4 August 2024
24 Juni 2024
24 Juni 2024
23 Juni 2024
23 Juni 2024
23 Juni 2024
23 Juni 2024
22 Juni 2024
21 Juni 2024
21 Juni 2024