UT225B
UT225B
P/N:110401111909X
 
High Voltage Transformer Turns Ratio Tester
Content
I. .............................................................................................................. Safety Information 1
II. Introduction ......................................................................................................................... 4
III. Electrical Symbols ............................................................................................................... 4
IV. Technical Specifications ..................................................................................................... 4
V. External Structure ............................................................................................................... 4
VI. 4 Operating Instructions .........................................................................................................
1. Power On/Off the Primary High Voltage Clamp Sensor - ............................................. 2
2. Power On/Off the Tester ............................................................................................. 2
3. Testing of High Voltage Current and Overhead Current - ............................................ 2
4. Secondary Low Voltage Current Testing - ................................................................... 2
5. Testing of Turns Ratio and Phase Identification ......................................................... 2
6. Data Hold/Storage ...................................................................................................... 2
7. Data Viewing/Deletion ................................................................................................ 2
8. Data Uploading ........................................................................................................... 2
VII. Battery Replacement ........................................................................................................... 4
VIII. Packing List ........................................................................................................................ 4
I. Safety Information
Thank you for purchasing the product. Before performing on site test, please carefully read the -
instructions in the user manual and make sure you are skilled at operating the product, and please
follow the safety information and precautions listed in the user manual.
îš‹ Pay special attention to safety when using the product, especially for measuring circuit with
voltage over AC 100V.
îš‹ It is forbidden to test bare conductor or bus bar with voltage over 35kV.
îš‹ Insulation stick must be connected if the voltage of measured line is over 600V.
îš‹ - On site testing must be performed by authorized trained personnel.
îš‹ Please pay attention to the labeled words and symbols at the front and rear panels of the product.
îš‹ Do not keep the product in places with high temperature, high moisture, dew or direct sunlight
for a long time.
îš‹ Be sure the battery polarity is correct when replacing battery, remove the battery if not used for
a long time.
îš‹ Use, disassembling and maintenance must be performed by authorized qualified personnel.
îš‹ Avoid impact on the clamp jaws. Perform regular maintenance on the product, do not use
corrosive or coarse material to clean the product, please mildly wipe the product through soft cloth
(i.e. glasses rust dehumidifying lubricant (i.e. WDcloth) dipped with anti- -40).
îš‹ Please stop using the product if it poses danger during use.
 The danger symbol “ ” at the product and the user manual identifies that the operator must
perform safe operation according to the instruction.
 The extreme danger symbol “ ” at the user manual identifies that the operator must strictly
perform safe operation according to the instruction.
îš‹ It is recommended to perform dielectric test on the product once a year at least (AC 60kV/rms
b etween both ends 5 pieces of connected insulation sticks).
II. Introduction
UT225B High-Voltage Transformer Turns Ratio Tester makes a breakthrough on conventional
structure. It is designed and manufactured to test primary current, secondary current and turns ratio
of transformer below 35kV, and identify phase type and polarity. UT225B consists of primary clamp
sensor (high ge clamp sensor), secondary clamp sensor, tester, high voltage insulation stick, -volta -
monitor software, communication line, etc. The primary clamp sensor can transmit testing data in
a wireless manner, with transmission distance at 100 meters.
Made up of high performance permalloy and designed with magnetic shielding technology, the -
clamp sensor can resist external magnetic fields and continuously perform monitoring with high
accuracy, stability and reliability.
The LCD of the tester can display contents clearly. The tester has an ultra large storage capacity
to store up to 3000 groups of data.
Connected with 5 pieces of insulation sticks, the high voltage clamp sensor can be applied to -
measure current of insulated line below 60kV or high/low voltage bare conductor below 36kV. The -
special automatic plugging structure enables the high voltage clamp sensor to clamp onto or -
remove from the measured conductor easily and fast. The insulation stick is characterized by
lightweight, moisture- - -proof, impact resistant, bending resistant, and highly insulated (insulation
level: 110kV). UT225B is extensively used to inspect current, prevent electricity theft and perform
field electrical operation for substation, power plant, power inspection department, industrial and
mining enterprise, inspection station, and electrical repair department.
1
Produktspezifikationen
Marke: | Uni-T |
Kategorie: | Messung |
Modell: | UT225B |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Uni-T UT225B benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Messung Uni-T
11 Juni 2024
11 Juni 2024
23 Mai 2024
19 Mai 2024
19 Mai 2024
15 Mai 2024
5 Mai 2024
2 Mai 2024
21 April 2024
20 April 2024
Bedienungsanleitung Messung
- Messung Hama
- Messung REV
- Messung Voltcraft
- Messung Bosch
- Messung Laserliner
- Messung Velleman
- Messung Powerfix
- Messung Alecto
- Messung Beurer
- Messung Bresser
- Messung König
- Messung TFA
- Messung Black And Decker
- Messung Trotec
- Messung DeWalt
- Messung Pioneer
- Messung Megasat
- Messung Smartwares
- Messung Garmin
- Messung GOCLEVER
- Messung Perel
- Messung Workzone
- Messung Microlife
- Messung Rossmax
- Messung Amprobe
- Messung Meec Tools
- Messung Metrix
- Messung IHealth
- Messung Ansmann
- Messung Westfalia
- Messung Livington
- Messung Silverline
- Messung Yato
- Messung Be Cool
- Messung Toolland
- Messung AS Schwabe
- Messung Hager
- Messung Kyoritsu
- Messung Eurolite
- Messung GW Instek
- Messung KERN
- Messung Milwaukee
- Messung Eizo
- Messung Testo
- Messung Victron Energy
- Messung Peak
- Messung KĂĽbler
- Messung Carrier
- Messung Lund
- Messung SHX
- Messung Gima
- Messung Testboy
- Messung Danfoss
- Messung Fantini Cosmi
- Messung Multimetrix
- Messung Extech
- Messung BENNING
- Messung Fluke
- Messung FLIR
- Messung Vemer
- Messung Oregon Scientific
- Messung Ridgid
- Messung Stabila
- Messung Hikmicro
- Messung Entes
- Messung Gossen Metrawatt
- Messung Hameg
- Messung Joy-it
- Messung Megger
- Messung Muller
- Messung PCE Instruments
- Messung RK Technology
- Messung Sanwa
- Messung Sonel
- Messung VirtuFit
- Messung Wachendorff
- Messung TFA Dostmann
- Messung Vimar
- Messung Owon
- Messung PeakTech
- Messung Comark
- Messung Dahua Technology
- Messung YSI
- Messung Aluratek
- Messung SRS
- Messung Eltako
- Messung H-Tronic
- Messung HT Instruments
- Messung Beha-Amprobe
- Messung Chauvin Arnoux
- Messung Werma
- Messung Eastron
- Messung Emko
- Messung Pancontrol
- Messung X-Rite
- Messung CESYS
- Messung Trumeter
- Messung Kemo
- Messung ORNO
- Messung Tempest
- Messung TDE Instruments
- Messung Zircon
- Messung Kreg
- Messung Apollo Ultrasonic
- Messung BJZ
- Messung Adwa
- Messung Greisinger
- Messung Qubino
- Messung Beckmann & Egle
- Messung WeidmĂĽller
- Messung Janitza
- Messung CEM
- Messung Klein Tools
- Messung Daytronic
- Messung AREXX
- Messung Delta Ohm
- Messung Camille Bauer
- Messung Rigel Medical
- Messung UHoo
- Messung Seaward
- Messung AstroAI
- Messung P3 International
- Messung Seek Thermal
- Messung ClimeMET
- Messung Fixpoint
- Messung Condtrol
- Messung Cliff
- Messung Water-i.d.
- Messung Stahlwille
- Messung KS Tools
- Messung AkYtec
Neueste Bedienungsanleitung fĂĽr -Kategorien-
4 August 2024
24 Juni 2024
24 Juni 2024
23 Juni 2024
23 Juni 2024
23 Juni 2024
23 Juni 2024
22 Juni 2024
21 Juni 2024
21 Juni 2024