Techly I-ALARM Water Leakage Detector Bedienungsanleitung

Techly Detektor I-ALARM Water Leakage Detector

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Techly I-ALARM Water Leakage Detector (4 Seiten) in der Kategorie Detektor. Dieser Bedienungsanleitung war für 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
Water Leakage Detector
www.techly.com EN
Introduction
This product is a Water leakage detector, using the princi-
ple of electrode immersed resistor changes to detect water.
The detector adopts MCU intelligent detection, rust-proof
metal probe design with advantages o fhigh accuracy and
sensitivity, low power consumption, long-term stability and
reliability, etc. It can be widely used in all water storage
equipment, such as basement, water tank, machine room,
water route, water tower, water cellar, pools, water room,
solar energy and anywhere to detect water leakage area.
Three optional models: Independent/ Network/ Wireless.
Product Prole
1) LED
2) TEST Button
3) Sensor
(Built-in magnet has
absorbed function)
5-PIN connector instruction (Network type only)
Red: DC Power anode
Black: DC Power cathode
White: COM (relay)
Orange: N.O. (relay)
Yellow: N.C. (relay)
1
2
3
Technical Specication
Type Wireless
Operating voltage DC3V (2x1.5V AA Alkaline Batteries)
Static current ≤10uA
Alarm current ≤40mA ≤50mA
Alarm indicator Red LED and buzzer sounding
Fault indicator Yellow LED
Alarm output 433MHz
Working Temperature 0-60°C
Humidity 0-80%RH (no congelation)
Sound level ≥85db/3M
Hush time 10 minutes
Installation wall mounted or board installed
Dimension 89*89*28mm (bracket not included)
Features
• Rust-proofMetalProbe,LongServiceLife
• SoundandFlashAlarm
• LowPowerConsumptionDesign
• TestandHushButton
• LowBatteryWarning
• MCUProcessing,ResistFalseAlarmEfficiently
• SMTManufactureTechnology,GoodStability
Installation Notice
1. Install the detector where the water is likely to leak.
2. Do not locate the detector in cabinet and other places
where the alarm sound can not came out easily.
3. Do not install it at the area with rain, oil smoke and
steam of cooking range.
4. Do not install the detector with submersed water.
Installation Steps
1. Attachthemountingbracketonthewallorboardfirmly
with screws.
2. Mount the rest ofthe detector into the bracket.
3. Puttheprobeintheoorwherethewaterislikelyto
leak. Or use the sensor magnetic adsorption where re-
quired detects water.
4. Connect the alarm to the power.
Operating Principle
1. Insert 2pcs 1.5V AA batteries into the battery cabinet
(independent or wireless type). Connect DC9-24V power
to 5-pin connector (network type). While the connected
DC power or battery voltage is more than 2.4V, the green
LEDashesoncewithbuzzersounding.Whilethevolt-
ageislessthan2.4V,theyellowLEDashesrapidlyfor
3timeswithbuzzersounding.Thenthedetectorcomes
into normal working status.
2. The green LED long lighting under DC power sup-
ply. While the operated with batteries, the green LED
ashesonceevery25secondstoindicatethenormal
power supply.
3. RoutinelylongpresstheTEST/HUSHbutton(>2seconds)
for testing to make sure the detector works properly.
Thered&greenLEDashesalternatelyafter2seconds
withbuzzersoundingevery3soundspauseduntilre-
lease the button. Moreover, the relay works (network
type) and send out wireless alarm signal (wireless type)
on testing.
4. Once the sensor detects leakage water, the red LED
ashes rapidly with buzzer sounding every 3 sounds
paused to warn the users. Moreover, the relay works
and output alarm signal (network type); it will send out
wireless alarm signal (wireless type) on alarming.
5. During alarming status, long or short press the TEST/
HUSH button to enters into mute status. The red &
greenLEDashesalternatelyonceevery1second,the
buzzerstopsounding,relayorRFmodelshuto;The
mute status will end automatically in 10 minutes later.
If still detects leakage after 10 minutes, the detector
will alarm again to warn users.
6.Short press theTEST/HUSHbutton on normal stateto
enterintomutestatus.Thebuzzersounds‘Di’onceand
green LED ashes every 1 second. While has leakage
water, the red & green LED ashes alternately once
every 1 second, but without any alarm signal, such as
sound,relayorRF.UserscanmopoororWashpoolon
mutestatus.Re-pressTEST/HUSHbuttontoendupthe
mute status.
7. Under alarming status, no matter long or short press
the button, it will goes into mute status. On alarming
and mute status, it will cancel mute after long or short
pressed the button.
8. The battery voltage will be down during usage process.
When the battery voltage <2.4V, the detector will give
outlowbatterysignal.TheyellowLEDashesonceeve-
ry50secondswiththebuzzersounding.
9. The detector will stop alarm automatically and reset to
normal working status after the leakage handled prop-
erly.
Register the detector on alarm system
Register the detector in the alarm system Switch to Con-
nection Mode on the control panel, press the test button
of the sensor twice. The control pannel beeps once: the
detector is registered. If you hear two beeps, the detector
has already been connected. To check if the registration is
complete, arm the system and trigger the sensor again. If
the siren rings out, the registration is successful.
Indications Summary
Indication Analysis
Green LED flashes once with
buzzer sounding
The battery (>2.4V) or DC power
supply
Yellow LED flashes rapidly for 3
times with buzzer sounding The battery (<2.4V) power supply
Green LED flashes constantly Normal, DC power supply
Green LED flashes every 25s Normal, battery power supply
Red and green LED flashes
alternately with buzzer sounding
every 3 sounds paused
Testing state, release the button
to exit
Red LED flashes with buzzer
sounding every 3 sounds paused
Alarming state, detects water or
touch conductive objects
Red and green LED flashes
alternately once every 1 second
without buzzer sounding
Alarming mute state, long/short
press TEST/HUSH button to cancel
mute state
Green LED flashes once every
second without buzzer sounding
Normal mute state, short press
TEST/HUSH button to cancel mute
state
Yellow LED flashes once every 50s
with the buzzer sounding
LOW battery warning, the voltage
<2.4V, the battery should be
replaced
Emergency Alarm Treatments
Treatments for water leakage alarm:
1. Shut of water valves.
2. Drain away the water and overhaul the tubes to reduce
the economic losses and water wastes caused by leak-
age water.
Notes
1. When the sensor detects water leakage and the detec-
tor still sit on alarming state after drain away the wa-
ter. It may the water residue of probe inside or surface.
Dry the water residue on surface with towel to check
whether the detector recovers to normal working sta-
tus.Ifstillonalarmingstate,takethesensoroand
shake the residue water out, dry the surface with towel
and installing then.
2. Replace the battery timely on low battery warning to
ensure the detector works properly,
3. Do not store any other subjects on the surface of detec-
tor,asthismayeecttheindicationandsounding.
4. Test the detector routinely to ensure proper operation.
Clean the surface with soft towel regularly.
5. Read carefully and install correctly as required in this
manual.Incasetheproductisfailure,doNOTtrytofix
it by yourself. Contact with your dealer for replacement.
in compliance with Eu Directive WEEE this product is market with
this symbol. It means that used electrical and electronic products
should not be mixed with general household waste. There is a
separate collections system for there products in compliance with WEEE
directive, otherwise contaminative and hazardous substances can pollute
the enviroment
With CE sign, Techly ensures that the product is conformed to the
basic European standards and directives.
Rilevatore di perdite
d’acqua
www.techly.com IT
Introduzione
Questoprodottoèunrilevatored’acqua,perrilevarel’acqua
usailprincipiocheglielettrodiimmersimodificanoleresi-
stenza.IlrilevatoreusaunrilevamentointelligneteMCU,è
dotato di una sonda a prova di ruggine con il vantaggio di
un’elevataprecisioneesensibilità,bassoconsumoenerge-
tico,stabilialungotermineel’adabiliPuòesseream-
piamente usato in tutti gli ambienti a rischio allagamento,
come scantinati, seminterrati, sala caldaia e boiler, bagni,
lavanderie, cucine, piscine e qualsiasi altro luogo che possa
presentaredelleperditeofuori-uscited’acqua.Tremodelli
opzionali:Indipendente/viaretenetwork/retesenzafili.
Aspetto del prodotto
1) LED
2) Tasto di test
3) Sensore (con
magnete
incorporato
confunzionedi
assorbimento)
Istruzioniperconnettore5-PIN(soloversionenetwork)
Rosso:anodoalimentazioneDC
Nero:catodoalimentazioneDD
Bianco: COM (relay)
Arancio:N.O.(relay)
Giallo:N.C.(relay)
1
2
3
Speciche tecniche
Tipo Wireless
Voltaggio operativo DC3V (2x batterie alcaline 1.5V AA)
Corrente statica ≤10uA
Corrente allarme ≤40mA ≤50mA
Indicatore allarme LED rosso e allarme sonoro
tramite cicalino
Indicatore guasto LED giallo
Uscita allarme 433MHz
Temperatura d’esercizio 0-60°C
Umidità 0-80%RH (no congelamento)
Livello del suono ≥85db/3M
Tempo di silenzio 10 minuti
Installazione montaggio a muro
Dimensioni 89*89*28mm (staffa non incluse)
Caratteristiche
•Sondaaprovadiruggine,lungadurata
•Allarmesonoroevisivo
•Abassoconsumoenergetico
•Tastoditestedisilenzio
•Avvisobatteriascarica
•ElaborazioneMCU,ecienteresistenzaaifalsiallarmi
•TecnologiadifabricazioneSMT,buonastabilità
Informazione Installazione
1. Installare il rilevatore dove è probabile rilevare delle
perdite.
2. Nonposizionareilrilevatoreall’internodiunarmadioo
inunospaziodovel’allarmesonoropuòvenireattutito.
3. Non installare l’apparecchio in un area con pioggia,
fumod’olioovaporedelpianodicottura.
4. Non installare il sensore con acqua sommersa.
Fasi dell’installazione
1. Installarelastaaalmuroinmodosaldoutilizzandole
viti.
2. Installareilrestodelrilevatoresullastaa.
3. Posizionarelasondasulpavimentodoveèpossibileri-
scontrarelaperditad’acqua.
4. Collegarel’allarmeall’alimentazione.
Principi di Funzionamento
1. Inserire2batterie1.5VAAnell’appositoalloggiamento
(tipoindipendenteowireless)Collegarel’alimentazio-
ne DC 9-24V al connettore 5-pin (tipo network). Quando
l’alimentatoreDCconnessooilvoltaggiodellebatterie
è superiore a 2.4V, il led VERDE lampeggia una volta con
l’emissionediunsegnaleaudiodalcicalino.Seilvol-
taggio è inferiore a 2.4V, il LED giallo lampeggia rapida-
mente per 3 volte e il cicalino suona. Quindi il rilvatore
passaallostatodifunzionamentonormale.


Produktspezifikationen

Marke: Techly
Kategorie: Detektor
Modell: I-ALARM Water Leakage Detector

Brauchst du Hilfe?

Wenn Sie Hilfe mit Techly I-ALARM Water Leakage Detector benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Detektor Techly

Bedienungsanleitung Detektor

Neueste Bedienungsanleitung für -Kategorien-