TDE Instruments Digalox DPM72-MPN Bedienungsanleitung
TDE Instruments
Messung
Digalox DPM72-MPN
Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr TDE Instruments Digalox DPM72-MPN (8 Seiten) in der Kategorie Messung. Dieser Bedienungsanleitung war fĂĽr 6 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/8
Digalox DPM72-MPN+
Instruction manual (Rev-2020-09)
Graphical panel meter for 500V/333mV AC/DC with RGB multi display
Package contents: Panel meter Digalox DPM72-MPN
+, mounting bracket,
5 jumpers, 2 instruction manuals (EN + DE)
1. Safety instructions
•Read instruction manual carefully before operating the device! Keep for later
reference.
•Mounting and installation must be carried out by suitably qualified and competent
persons only.
•WARNING: The measurement inputs of the device can carry life-threatening
voltages!
•When working on the device hazardous voltages must not be connected to
the device! The terminals J1-J12 are not isolated from the measuring
circuit.
•The device must not be used as the only protective device or protective
shutdown.
•The device is not intended to protect persons or facilities against harm. Specific
devices must be used to guarantee safety (protection relays, cut-off switches,
etc.).
•When connecting switches to the terminals J1-J6, only switches must be used
whose isolation voltage is at least twice the maximum occurring measurement
voltage. For example, when measuring 250;V AC switches must be isolated for at
least 500;V.
•Do not open the housing!
•Do not use the device in the presence of explosive or flammable substances!
•All cables carrying hazardous voltages must be secured with external separators.
2. Meaning of symbols
General warning sign
(Attention, observe the documentation!)
Warning of an electrical hazard
----- ----- 1 / 8
3. Intended use
•Measurement of current, voltage, power and frequency in the specified measuring
ranges.
•Indoor use non condensing, non corrosive.
•Panel mounting.
•In operation, supply the device preferably via screw terminals with 12 to 24;V
AC/DC. If the device is supplied via USB in operation, USB supply voltage must
be at least 5;V.
•Failure to comply with these instructions will void all guarantee and warranty.
4. Description
The multi display with RGB backlight is able to display up to four parameters
simultaneously. Thresholds can be associated with individual warning backlight
colours. A variety of measurement modes (volt AC/DC, ampere AC/DC via external
shunt, frequency, power, cos phi) are supported. The unit can be switched between
measurement modes via an external switch. Minimum and maximum values of up to
four parameters are recorded and can be displayed optionally using an external
switch. Measured values of one parameter are recorded over a time span of 36
seconds up to 14 days. The time base as well as the display of the measuring
history can be activated by an external switch. The measured values remain stored
as long as the device is supplied with voltage.
The following parameters can be adjusted using the configuration software “Digalox
Manager”: scale endpoint, scale caption, display style (pointer, tachometer, bar
graph, and more), splash image, backlight colour, thresholds for alarm output,
threshold warning colour (light, blink), hysteresis, and more. Recorded
measurement values can be read and a continuous transmission of up to four
measurement values can be enabled. Using the software, values can be viewed and
exported as CSV file. Depending on the model, measured values can be transmitted
via USB, XBEE radio technology or RS485 Modbus interface. In addition, the
devices feature a counting function with data retention. This enables operating-
hours-counters or time-counters for exceeding and falling below threshold values, as
well as ampere-hour and energy meters.
Visit to download the software “Digalox Manager”.www.digalox.com
----- ----- 2 / 8
5. Product overview
3
5
4
2
1
2
6
Front
1 Unit or free text
2 Threshold values
3 Upper scale caption
4 Graphical measurement display
5 Digital measurement value
6 Lower scale caption
USB
Digalox DPM72-MPN+
www.digalox.com
Made in Germany
Outputs max.
30 V
50 mA
–
Supply
12 - 24 V
~/
+
Mode 1
Mode 2
Mode 3
Autoscale
Min/Max
Timebase
Bus 1
Bus 2
NC
GPIO 1
G
PIO 2
NC
J1
J2
J3
J4
J5
J6
J7
J8
J9
J12
J11
J10
U2low U2high U1high U1low
Shunt 333 mV max. 500 V max.
5
4
3
2
1
Back
1 2 optocoupler switch outputs
2 Jumper pins J1–J12
for activating/switching of graphical
historic data display, min/max
display, auto-scaling, measurement
mode,...
3 Supply voltage input
4 Interface (USB / XBEE / RS485)
5 Measurement inputs
6. Mounting
Carefully insert the device into the panel
cut-out. Insert the mounting bracket from
the back and push towards the panel until
the device sits tight. Make sure the
mounting bracket is snapped into the side
of the housing. To ensure IP65 protection
(dust and water jet) when mounting in a
front panel, use optional gasket
(separately available).
----- ----- 3 / 8
Panel thickness: max. 6 mm
Press mounting
bracket
Produktspezifikationen
Marke: | TDE Instruments |
Kategorie: | Messung |
Modell: | Digalox DPM72-MPN |
Brauchst du Hilfe?
Wenn Sie Hilfe mit TDE Instruments Digalox DPM72-MPN benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Messung TDE Instruments
23 März 2024
15 Februar 2024
24 August 2023
Bedienungsanleitung Messung
- Messung REV
- Messung Voltcraft
- Messung Bosch
- Messung Laserliner
- Messung Velleman
- Messung Bresser
- Messung König
- Messung TFA
- Messung Black And Decker
- Messung Trotec
- Messung DeWalt
- Messung Megasat
- Messung Smartwares
- Messung Garmin
- Messung GOCLEVER
- Messung Perel
- Messung Workzone
- Messung Microlife
- Messung Rossmax
- Messung Amprobe
- Messung Meec Tools
- Messung Metrix
- Messung Yato
- Messung Be Cool
- Messung Hager
- Messung Kyoritsu
- Messung GW Instek
- Messung Milwaukee
- Messung Eizo
- Messung Testo
- Messung Victron Energy
- Messung Peak
- Messung KĂĽbler
- Messung Carrier
- Messung Lund
- Messung SHX
- Messung Gima
- Messung Testboy
- Messung Fantini Cosmi
- Messung Multimetrix
- Messung Extech
- Messung BENNING
- Messung Fluke
- Messung FLIR
- Messung Vemer
- Messung Ridgid
- Messung Stabila
- Messung Entes
- Messung Gossen Metrawatt
- Messung Hameg
- Messung Joy-it
- Messung Megger
- Messung PCE Instruments
- Messung RK Technology
- Messung Sanwa
- Messung Sonel
- Messung Uni-T
- Messung Wachendorff
- Messung TFA Dostmann
- Messung Vimar
- Messung Owon
- Messung PeakTech
- Messung Dahua Technology
- Messung YSI
- Messung Aluratek
- Messung Eltako
- Messung H-Tronic
- Messung HT Instruments
- Messung Beha-Amprobe
- Messung Chauvin Arnoux
- Messung Werma
- Messung Eastron
- Messung Pancontrol
- Messung X-Rite
- Messung CESYS
- Messung Trumeter
- Messung ORNO
- Messung Zircon
- Messung Kreg
- Messung Adwa
- Messung Greisinger
- Messung Qubino
- Messung WeidmĂĽller
- Messung Janitza
- Messung CEM
- Messung Klein Tools
- Messung Daytronic
- Messung AREXX
- Messung Delta Ohm
- Messung Camille Bauer
- Messung Rigel Medical
- Messung Seaward
- Messung AstroAI
- Messung P3 International
- Messung Seek Thermal
- Messung ClimeMET
- Messung Fixpoint
- Messung Condtrol
- Messung Cliff
- Messung Water-i.d.
- Messung Stahlwille
- Messung KS Tools
- Messung AkYtec
Neueste Bedienungsanleitung fĂĽr -Kategorien-
4 August 2024
24 Juni 2024
24 Juni 2024
23 Juni 2024
23 Juni 2024
23 Juni 2024
23 Juni 2024
22 Juni 2024
21 Juni 2024
21 Juni 2024