Tanita AB-140M - Abdominal Fat Analyser Bedienungsanleitung

Tanita Diversen AB-140M - Abdominal Fat Analyser

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Tanita AB-140M - Abdominal Fat Analyser (19 Seiten) in der Kategorie Diversen. Dieser Bedienungsanleitung war für 20 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/19
Abdominal Fat Analyser AB-140M
Instruction Manual
Thank you for purchasing the AB-140M Abdominal Fat Analyser.
Misuse of this device may result in a serious accident.
Please ensure that you read this Instruction Manual
thoroughly prior to use and store it in a convenient
location for easy reference.
N.B.
3
Prior to UsePrior to Use
2
How toUsePrior to Use As Needed
Table of contents
For Your Safety ••••••••••••••••••••••••••••••••••••••••••••••••••••3
Laser Security••••••••••••••••••••••••••••••••••••••••••••••••••••••5
How to Measure Correctly and Points to Remember ••••••••••6
Parts and Attachments ••••••••••••••••••••••••••••••••••••••••••••8
Before You Start••••••••••••••••••••••••••••••••••••••••••••••••••10
•Charging the Battery (main unit)
•Inserting Batteries (Impedance Meter)
•Positioning the Unit Correctly
Measuring ••••••••••••••••••••••••••••••••••••••••••••••••••••••13
Standard Mode •••••••••••••••••••••••••••••••••••••••••••••••••••13
Waist Circumferences Over 130cm
••••••••••••••••••••••••••••••••21
Connecting to Your Computer ••••••••••••••••••••••••••••••••••25
Calibration ••••••••••••••••••••••••••••••••••••••••••••••••••••••••26
Changing the Main Unit Battery ••••••••••••••••••••••••••••••••29
Transporting the Unit ••••••••••••••••••••••••••••••••••••••••••••31
Reading Results••••••••••••••••••••••••••••••••••••••••••••••••••32
•Estimated Waist Circumference
•Visceral fat rating
Trunk fat %
Troubleshooting••••••••••••••••••••••••••••••••••••••••••••••••••34
Product Specifications•••••••••••••••••••••••••••••••••••••••••••35
The AB-140M makes use of the abdominal Bioelectrical Impedance Analysis (BIA)
method to directly measure the abdomen of a subject in the supine position. With this
method, the previously difficult task of managing the health of people who are unable to
stand or are otherwise disabled becomes possible.
The AB-140M also has the latest reactance technology functions, which allows analyses
to reflect cellular changes in the abdominal cavity and individual differences.
The AB-140M is recommended for use in the following fields.
•To manage the health and encourage the education of people for whom analysis has previously
been impossible, such as the disabled and the obese.
•To determine the effectiveness of rehabilitation and sports training.
•To determine the effectiveness of dietetic and exercise treatment.
Analyses can now be made of people for whom
it was previously impossible.
For Your Safety
Prohibited
Warning Ignoring instructions highlighted with this mark could result in death or
severe injury.
Caution Ignoring instructions highlighted with this mark could result in injury or
damage to property.
This mark indicates actions that are prohibited.
This mark indicates instructions that must always be adhered to.
Warning
The following outlines precautionary measures to be taken to avoid injury to the users of this device
and others, and to prevent damage to property. Please familiarise yourself with the contents to
ensure the safe operation of this equipment.
This device must not be used on subjects with pacemakers or other
mechanical implants.
This device passes a weak electrical current through the body which could interfere
with and cause the malfunction of electrical medical implants, resulting in serious
repercussions.
This device must not be used on women who are pregnant or may be
pregnant as the foetus may be affected.
Do not dismantle or modify.
There is a risk of electrocution or injury. Nor can precise analysis be guaranteed.
Do not use double adapters.
May result in fire.
Do not interpret analysis results yourself (including evaluating
measurements and formulating exercise programmes based on
results, etc.).
Weight loss and exercise based on self-analysis could be detrimental to your health.
Always follow the advice of a qualified professional.
Do not shine the laser beam directly into the eyes.
Damage to eyesight may occur.
always adhere to the following
54
Prior to Use
Prior to Use
For Your Safety
Caution
Take care near water.
To avoid damage, do not use this device near water or other places where it may get
wet.
To avoid injury, do not insert fingers into gaps and holes.
Avoid impacts on the display.
The acrylic screen may split and cause injury.
Quickly remove moisture from the display screen to avoid, deformity, colour change,
staining and fading.
Wipe over the impedance meter electrodes with disinfectant (alcohol, etc.) prior to
measuring.
This is to avoid the transmission of disease when the meter is placed on the abdomen.
Use only the dedicated AC adapter and cord.
The use of other adapters/cords may result in damage or fire.
Ensure disabled persons do not attempt to use the equipment by themselves.
A companion must perform the measurements.
Continually monitor both the subject and the equipment for anomalies.
Should an anomaly with the subject or the equipment be discovered, take appropriate action, such as
stopping the equipment, while ensuring the safety of the subject.
Do not expose items sensitive to magnetic forces to the equipment.
Exposing items that may be affected by the magnetic force of the magnet on the impedance meter (floppy
disks, USB memory sticks, etc.) may result in corruption of data.
Avoid using on subjects with allergies to metals.
Allergic reactions may be caused by the stainless steel used in the electrodes of this device.
always adhere to the following (cont’d)
Prohibited
Always…
Laser Security
Caution
Specifications
Use of controls or adjustments or performance of procedures other than those specified
herein may result in hazardous radiation exposure.
Always…
Viewing the laser output with certain optical instruments (for example, eye loupes,
magnifiers and microscope) within a distance of 100mm may pose an eye hazard.
Do not shine the laser beam directly into the eyes.
Damage to eyesight may occur.
Prohibited
Warning
An explanation label
As for a label attached position, refer to “Parts and Attachments” (
P.8).
Beam Divergence About 90˚
Beam size
At a distance of 200mm: minimum line length 200mm; light width max.
2mm
Point ± 5mm from the centre (point is approx. Ø 2).
Classification Class 1M laser product (EN60825-1 (1994) + A2 (2001) + A1 (2002))
(IEC60825-1 (2001))
Laser
(for positioning)
Light emitter Visible light semiconductor laser
Laser wavelength Wavelength: 650 nm (red light)
Laser output Max. 1mW
Laser Diode DL–3147–031 (Made in SANYO Electric Co., Ltd.)
Short wavelength=650nm, Light Output Po=5mW (only the LD)


Produktspezifikationen

Marke: Tanita
Kategorie: Diversen
Modell: AB-140M - Abdominal Fat Analyser

Brauchst du Hilfe?

Wenn Sie Hilfe mit Tanita AB-140M - Abdominal Fat Analyser benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Diversen Tanita

Bedienungsanleitung Diversen

Neueste Bedienungsanleitung für -Kategorien-