Operating instruction lab
power supply unit
type 3225.71
The intended application of the power supply unit covers:
- link and operation of low-voltage consumers with an operating voltage between 2x(0 to 30 VDC) and 1x (0 to
40VDC/0-3A . Fixed output 5VDC/5A The power input of the consumer may not exceed 4,0 A. Output 1 to 3 can
be connect parallel or series.
Note! Absolutely read!
- Read this guidance exactly. With damage, which is caused by neglect of the guidance, the warranty claim goes
out. For damages we do not take over adhesion.
1. introduction
this power supply unit is universally applicable with its infinitely variable adjustment possibilities of voltage and
current for school, occupation, hobby etc.. An electronic current limiting protects the power supply unit against
overloading. Output voltage and - current are electronically stabilized and infinitely variable adjustable. Thus the
electronic restraint current can as adjustable Current limiting to be used, in order to protect consumers against a too
high power input. In the case of an overloading the output voltage is then lowered accordingly (in the case of short-
circuit on close 0V). With removal of the overload the output voltage adjusted before resets itself automatically. The
respective operating point - voltage - (u) - or restraint current (i) - is displayed by one red LED each. The adjusted
values are readable over 2 LCD displays each. The voltage or current adjustment is made by one wirewount
potenbtiometers ten turns.
2. Safety instructions
2.1 The power supply unit is in protection class I. The safety measures comply with DIN EN61010 and DIN EN
60950. The transformers comply with DIN EN 61558 and have passed the primary/secondary 3.75 kVeff
tests.
2.2 Check that the protective grounding conductor (yellow/green) is not disconnected either from the mains
cable or in the unit, since a disconnected protective conductor may lead to a risk of death. Also check
that the insulation is not damaged or destroyed.
2.3 Power supply units must be kept out of the reach of children!
2.4 In commercial establishments, the safety regulations of the professional trade association for electrical
appliances and equipment must be observed.
2.5 In schools, educational establishments, hobby and independent workshops, there must be careful
supervision that power supply units are operated by trained personnel.
2.6 When opening covers or removing components, apart from when this can be done by hand, live parts
may be exposed. Connections may also be live. Before adjustment, maintenance, repair or replacement of
components, the unit must be disconnected from any power source, if opening the unit is necessary.
Thereafter, if adjustment, maintenance or repair of the open unit when it is connected to the power
supply is unavoidable, this may only be carried out by a specialist engineer familiar with the associated
risks and relevant regulations.
2.7 The capacitors in the unit may still carry a charge, even when the unit is disconnected from any power
supply.
2.8 Check that only fuses of the type and fuse current rating indicated are used as replacements. The use of
repaired fuses or bridging of the fuse holder is not permitted. The unit is protected against overloading
and short-circuits. If the primary fuse melts, there is a serious fault which must be dealt with by a
specialist engineer. After successful repair, a new fuse link can then be installed by an engineer.
2.9 Do not switch on the power supply unit if it has been moved from a cold to a warm place. In unfavorable
conditions, the condensed water released on thawing can destroy your unit or cause life-threatening
voltages at the output terminals. Ensure that the unit can warm up to room temperature without any
adjacent mains current.
2.10 When working with power supply units, you are not permitted to wear any metallic or conductive jewelry
like chains, bracelets, or similar.
2.11 Power supply units are not permitted for use on human beings or animals.
2.12 Series connection of the outputs of one or more mains power units causes life-threatening voltages (>35
VDC).
2.13 The vents on the mains supply units must not be covered! The units must be placed on firm, non-
flammable surfaces, so that the air can enter unhindered. Cooling of the appliances occurs by forced
ventilation.
2.14 The mains supply units and the consumer loads connected to them must not be operated without
supervision. Measures must be taken to ensure the safety and protection of connected loads against
effects caused by the mains power supply unit (e.g. overload, breakdown of the mains appliance) and by
the connected loads themselves (e.g. current consumption above the permitted level).
Warning! Sensitive consumer loads must be protected against damage
by additional external measures!
2.15 In case of fault, power supply units can output voltages over 50V DC, which causes risk,
even if the specified output voltages of the units are lower.
2.16 When working with electrical voltages, only tools expressly permitted for the purpose are to be used.
2.17 The outputs of the power supply units (output bushes/terminals) and leads attached to them must be
protected against direct contact. The leads used must therefore have a sufficient level of insulation
and/or dielectric strength and the contact points must be protected from being touched (safety bushes).
2.18 Connection of uninsulated metallic leads and contacts must be avoided. All of these points must be
protected with suitable, non-flammable insulation material or with other measures. The electrically
conductive components of the connected loads must also be protected from direct contact by
appropriate measures.
2.19 If it becomes apparent that safe operation is no longer possible, the unit must be disabled and secured
against unintentional operation. It is apparent that safe operation is no longer possible when:
- the unit or the mains cable show visible signs of damage
- the unit no longer works
- it has been stored for a long time under unsuitable conditions
- it has been transported under difficult conditions
3. Controls
4. Line-up
a) The euro - connector of the power supply unit into
- Note! With longer operation with max. current consumption or in the case of short-circuit the radiator
box in the power supply unit becomes very heat. An overloading of the power pack is displayed by the red LED "
temperature rise ". At the same time by lowering the original data of the longitudinal automatic controllers of the dc
souurce against thermal overloading one protects.
Pay attention therefore absolutely to a sufficient ventilation of the power supply unit not uncover, it never the
ventilation slots at the device lower surface and at the rear wall the air outlet opening of forced cooling. Absolutely
make sure when connecting a consumer that this is not attached in the switched on status. A switched on consumer can
lead with the link to the output terminals of the power supply unit to a sparking at the connecting terminals, which again
b) Adjustable of the voltage
Turn first the adjusting knob for the current limiting a little to the right side (in the clockwise direction), until the LED (=
light emitting diode) for current limiting is not lighting. In the same instant the LED for the voltage adjustment begins to
light up. Now you can adjust the desired output voltage. The LCD display shows the adjusted output voltage.
c) Adjustment of the current limiting closing it the output
1-power switsch
2 4mm sockets source 1
3 4mm sockets source 2
4 4mm sockets source 3
5 4mm sockets source 3
6 LCD - voltage display source 1
7 LCD current display source 1
8 poti voltage source 1
9 poti current source 1
10 LED constant current operation source 1
11 LED constant current operation source 1
12 LED temperature rise source 1
13 LED output source 4
source 1 to 3 ar in the handling the same !


Produktspezifikationen

Marke: Statron
Kategorie: Nicht kategorisiert
Modell: 3225.71

Brauchst du Hilfe?

Wenn Sie Hilfe mit Statron 3225.71 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Statron

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-