Skytech 1001 - A remote control system Bedienungsanleitung

Skytech Diversen 1001 - A remote control system

Lesen Sie kostenlos die šŸ“– deutsche Bedienungsanleitung fĆ¼r Skytech 1001 - A remote control system (6 Seiten) in der Kategorie Diversen. Dieser Bedienungsanleitung war fĆ¼r 16 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/6
MODEL: 1001 - A
INSTALLATION AND OPERATION INSTRUCTIONS
IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO
NOT ATTEMPT TO INSTALL OR OPERATE
INTRODUCTION
The transmitter operates on a 12V (A23) battery that is included. Install the 12V battery sup-
plied with the unit into the battery compartment. It is recommended that ALKALINE batteries
always be used for this product. Be sure the batteries are installed with the (+) and (-)
ends facing the correct direction.
The LED signal light should illuminate when either the ON or OFF button is pressed. If the
signal light does not illuminate, check the position of the transmitterā€™s battery, and if the bat-
tery is fully charged.
TRANSMITTER
REV 4/15/11 Page 1
This remote control system was developed to provide safe, reliable, user-friendly remote control system for gas heating appliances. The
system can be operated manually from the transmitter.
ON
OFF
FRONTBACK
SIGNAL
LIGHT
ON/OFF
BUTTONS
BAT TERY
COMPARTMENT
RECEIVER
Install the (4) AA-size batteries supplied with the unit. It is recommended that ALKALINE batteries always be used for this product. Be
sure the batteries are installed with the (+) and (-) ends facing the correct direction.
ONā€¢ī€ƒ : will manually turn on the appliance.
REMOTEā€¢ī€ƒ : will allow use of handheld transmitter. If the system does not respond
to the transmitter on initial use, check the battery positions in the remote. If that
does not work, see the SECURITY CODE section.
OFFā€¢ī€ƒ : will disable the remote receiver.
It is suggested that the slide switch be placed in the OFF position if you will ā€¢ī€ƒ
be away from your home for an extended period of time.
REMOTE
ON
OFF
LEARN
Requires 4-AA 1.5V
alkaline batteries
Learning
button
Remote Receiver
Battery cover slides on/off
Slide
Switch
ON
REMOTE
OFF
The remote receiver has a 3-position slide switch for selecting the mode of operation
ON/REMOTE/OFF
Skytech 1001-A
INSTALLATION
The remote receiver can be either wall-mounted in a standard plastic switch box (not metal) or placed on or near the ī‚æreplace hearth.
Preferably, the remote receiver should be wall-mounted in a plastic switch box, as this will protect its electronic components from the
heat produced by the gas appliance. The remote receiver should be kept away from temperatures exceeding 130Āŗ F. Battery life is
also signiī‚æcantly shortened if batteries are exposed to temperatures 130ĀŗF or higher.
Before installation make sure the remote receiver slide switch is in the OFF position. After installation be sure that the slide switch is
moved to the REMOTE position.
MOUNTING THE REMOTE RECEIVER
Position the receiver as shown in diagram to
the left with lower tab on cover plate inserted
into groove of receiver (Make sure LEARN
hole on cover plate properly aligns with remote
receiver). Pull receiver up and snap into top
tab of cover plate.
Position the cover plate so the word ON is fac-
ing up; then, install the remote receiver into the
plastic switch-box using the two long screws
provided. Push the white button over the re-
ceiver slide switch.
Remote Receiver
Cover Plate
(Rear View)
To attach Cover Plate to Receiver Box:
REV 4/15/11 Page 2
R
E
M
O
T
E
ON
OFF
LEARN
WALL
Plastic Switch Box
Cover Plate
Receiver
Slide
Button
HEARTH MOUNT
The remote receiver can be placed on the ī‚æreplace hearth or under the ī‚ære-ā€¢
place behind the control access panel.
Use the wires attached to the remote receiver to connect to the gas valve or ā€¢
the electric module (piggyback connectors have both male & female terminals
for īƒ€exibility).
Be sure that the connectors do not touch each other or other bare metal ā€¢
surfaces; this will cause the appliance to turn on. The connectors may be
wrapped with electrical tape to prevent this.
WALL MOUNT
When wall mounting the remote receiver, longer wires (not included) are required to connect to the gas valve or electronic module.
These wires must:
Be at least 18 Gauge (AWG)ā€¢
Be no longer than 20ā€™ā€¢
Have no splicesā€¢
WARNING
This remote control system must be installed exactly as outlined in these instructions. Read all instructions completely before at-
tempting installation. Follow instructions carefully during installation. Any modiī‚æcations of this remote control or any of its compo-
nents will void the warranty and may pose a ī‚ære hazard.
Do not connect any gas valve or electronic module directly to 110-120VAC power. Consult gas appliance manufacturerā€™s instruc-
tions and wiring schematics for proper placement of all wires. All electronic modules are to be wired to manufacturerā€™s speciī‚æca-
tions.
The following wiring diagrams are for illustration purpose only. Follow instructions from manufacturer of gas valve and/or electronic
module for correct wiring procedures. Improper installation of electric components can cause damage to electronic module, gas
valve and remote receiver.
Skytech 1001-A
ELECTRONIC SPARK SYSTEM CHECK
Slide the 3-position button on the remote receiver to the ā€¢ī€ƒ ON position. The spark electrode should begin sparking to ignite the pilot.
Afterī€ƒtheī€ƒpilotī€ƒīƒ€ameī€ƒisī€ƒlit,ī€ƒtheī€ƒmainī€ƒgasī€ƒvalveī€ƒshouldī€ƒopenī€ƒandī€ƒtheī€ƒmainī€ƒgasī€ƒīƒ€ameī€ƒshouldī€ƒignite.
Slide the button to ā€¢ī€ƒ OFF.ī€ƒī€ƒTheī€ƒmainī€ƒgasī€ƒīƒ€ameī€ƒandī€ƒpilotī€ƒīƒ€ameī€ƒshouldī€ƒbothī€ƒextinguish.
Slide the button to ā€¢ī€ƒ REMOTE,ī€ƒthenī€ƒpressī€ƒtheī€ƒON button on the transmitter to change the system to on. The spark electrode should
beginī€ƒsparkingī€ƒtoī€ƒigniteī€ƒtheī€ƒpilot.ī€ƒī€ƒAfterī€ƒtheī€ƒpilotī€ƒisī€ƒlit,ī€ƒtheī€ƒmainī€ƒgasī€ƒvalveī€ƒshouldī€ƒopenī€ƒandī€ƒtheī€ƒmainī€ƒgasī€ƒīƒ€ameī€ƒshouldī€ƒignite.
LEARNING TRANSMITTER TO RECEIVER
ā€¢ī€ƒ
Each transmitter uses a unique security code. It will be necessary to press the LEARN button on the receiver to accept the trans-ā€¢ī€ƒ
mitterī€ƒsecurityī€ƒcodeī€ƒuponī€ƒinitialī€ƒuse,ī€ƒifī€ƒbatteriesī€ƒareī€ƒreplaced,ī€ƒorī€ƒifī€ƒaī€ƒreplacementī€ƒtransmitterī€ƒisī€ƒpurchasedī€ƒfromī€ƒyourī€ƒdealerī€ƒorī€ƒtheī€ƒ
factory.ī€ƒī€ƒInī€ƒorderī€ƒforī€ƒtheī€ƒreceiverī€ƒtoī€ƒacceptī€ƒtheī€ƒtransmitterī€ƒsecurityī€ƒcode,ī€ƒbeī€ƒsureī€ƒtheī€ƒslideī€ƒbuttonī€ƒonī€ƒtheī€ƒreceiverī€ƒisī€ƒinī€ƒtheī€ƒREMOTEī€ƒ
position;ī€ƒtheī€ƒreceiverī€ƒwillī€ƒnotī€ƒLEARNī€ƒifī€ƒtheī€ƒslideī€ƒswitchī€ƒisī€ƒinī€ƒtheī€ƒONī€ƒorī€ƒOFFī€ƒposition.ī€ƒī€ƒTheī€ƒLEARNī€ƒbuttonī€ƒinī€ƒlocatedī€ƒonī€ƒtheī€ƒfrontī€ƒfaceī€ƒ
of the receiver; inside the small hole labeled LEARN. Using a small screwdriver or end of a paperclip gently press and release
the black LEARN button inside the hole. When you release the LEARN button the receiver will emit an audible ā€œbeepā€. After the
receiver emits the beep press ANY transmitter button and release. The receiver will emit several beeps indicating that the transmit-
terā€™s code has been accepted into the receiver.
REV 4/15/11 Page 3
WIRING ELECTRONIC SPARK IGNITIONS
ELECTRONIC MODULE
TR TH
REMOTE
RECEIVER
neutral wire
24VAC
hot wire
120VAC
110/24VAC
Transformer
Theī€ƒremoteī€ƒcontrolī€ƒreceiverī€ƒcanī€ƒbeī€ƒconnected,ī€ƒinī€ƒseries,ī€ƒtoī€ƒaī€ƒ24VACī€ƒ
transformerī€ƒtoī€ƒtheī€ƒTRī€ƒ(transformer)ī€ƒterminalī€ƒonī€ƒtheī€ƒELECTRONICī€ƒ
MODULE.ī€ƒī€ƒConnectī€ƒtheī€ƒhotī€ƒwireī€ƒfromī€ƒtheī€ƒ24VACī€ƒtransformerī€ƒtoī€ƒeitherī€ƒ
ofī€ƒtheī€ƒwireī€ƒterminalsī€ƒonī€ƒtheī€ƒremoteī€ƒreceiver.ī€ƒī€ƒConnectī€ƒanotherī€ƒwireī€ƒbe-
tween the other receiver wire terminal and the TH (thermostat) terminal
onī€ƒtheī€ƒELECTRONICī€ƒMODULE.
WIRING INSTRUCTIONS
Aī€ƒqualiī‚æedī€ƒelectricianī€ƒshouldī€ƒinstallī€ƒtheī€ƒremoteī€ƒcontrolī€ƒsystem.
TERMINAL BLOCK
ON MILLIVOLT
GAS VALVES
TH
TP TP TH
THERMOPILE/
PILOT LIGHT
REMOTE
RECEIVER
Connectī€ƒoneī€ƒwireī€ƒfromī€ƒtheī€ƒremoteī€ƒreceiverī€ƒtoī€ƒtheī€ƒTHī€ƒterminalī€ƒonī€ƒtheī€ƒgasī€ƒā€¢ī€ƒ
valve.
Connectī€ƒtheī€ƒotherī€ƒwireī€ƒfromī€ƒtheī€ƒremoteī€ƒreceiverī€ƒtoī€ƒtheī€ƒTH/TPī€ƒterminalī€ƒonī€ƒā€¢ī€ƒ
the gas valve.
WIRING MILLIVOLT VALVES
MILLIVOLT SYSTEM CHECK
Ensureī€ƒthatī€ƒtheī€ƒpilotī€ƒīƒ€ameī€ƒisī€ƒlit.ā€¢ī€ƒ
Slide the 3-position button on the remote receiver to the ā€¢ī€ƒ ONī€ƒposition.ī€ƒī€ƒTheī€ƒmainī€ƒgasī€ƒīƒ€ameī€ƒ(i.e.,ī€ƒtheī€ƒī‚ære)ī€ƒī€ƒī€ƒ
should ignite.
Slide the button to ā€¢ī€ƒ OFF.ī€ƒī€ƒTheī€ƒmainī€ƒīƒ€ameī€ƒshouldī€ƒextinguishī€ƒ(theī€ƒpilotī€ƒīƒ€ameī€ƒwillī€ƒremainī€ƒon).
Slide the button to ā€¢ī€ƒ REMOTE,ī€ƒthenī€ƒpressī€ƒtheī€ƒON button on the transmitter to change the system to on. The main
gasī€ƒīƒ€ameī€ƒshouldī€ƒignite.
Skytech 1001-A


Produktspezifikationen

Marke: Skytech
Kategorie: Diversen
Modell: 1001 - A remote control system

Brauchst du Hilfe?

Wenn Sie Hilfe mit Skytech 1001 - A remote control system benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Diversen Skytech

Bedienungsanleitung Diversen

Neueste Bedienungsanleitung fĆ¼r -Kategorien-