T he rmo elec tric va lve dr ive, 23 0 VDevices f or s ingle-ro o m h eatin gArt. no. 6391 25Versio n 09/04Valve drives
The 230 V thermoelectric valve drive is used to open
and shut valves in heating, ventilation and air
conditioning technology. It is controlled by a room
temperature control unit (230 V) with a two-step
output or pulse width modulation.
A large selection of valve adapters ensures that it
conforms perfectly to a range of valve bodies and
heating circuit distributors. The 230 V thermoelectric
valve drive therefore has universal applicability and is
suitable for a diverse range of systems.
De-energised - closed
The control mechanism of the thermoelectric valve
drive works with a PTC-heated expanding element and
a compression spring. The expanding element is
heated when the operating voltage is applied. After
the delay period has expired, the valve will open
uniformly. When the operating voltage is switched off,
the expanding element will cool down and, when the
idle time has expired, the valve will be closed
uniformly by the closing pressure of the compression
spring. The closing pressure of the compression
spring (90 N controlling torque) has been matched to
the closing pressure of commercially available valves
and holds the valve closed in its de-energised state.
First-open function
In the supplied state, the 230 V thermoelectric valve
drive is opened without current using the first-open
function. This makes it possible to operate the heating
during the shell construction phase, even if the
electrical wiring of the single room heating has not
been completed. When started up at a later stage, the
first-open function is automatically released when the
operating voltage is applied (for longer than 6 min), and
the 230 V thermoelectric valve drive is then ready to
function normally.
Functional display
The functional display of the thermoelectric valve drive
(all-round display) makes it possible to see the
operating status (valve "open", "closed" or in an
intermediate position) at a glance.
– Functional display
– Adjustment control
– Disassembly protection by
– 360° installation position
– Valve leak protection
– First-open function
– Plug-in connecting cable
– Valve adapter
– Plug-in assembly
– Functional design
– Compact construction, small dimensions
– For two-step control in heating, air conditioning and
ventilation systems
– Single room heating of radiant panel heating
– Easy control of heating circuit distributors, radiators,
convectors, cooling ceilings and similar devices
1 230-V thermoelectric valve drive with 1-m cable
1 installation manual
Valve adapter for the most common valves on the
market
VA 10 MTN639110 (Dumser; Vescal; Simplex)
VA 50 MTN639150 (Honeywell & Braukmann;
Reich; Landis & Gyr;
MNG; Cazzagniga)
VA 78 MTN639178 (Danfoss RA)
VA 80 MTN639180 (Heimeier; Herb; Onda;
Schlösser (from 1993);
Oventrop M30x1.5;
TeSa)
Optional longer connecting cable (max. 2 m)
Protective cap AA SK 1000 (available on request).
|To install the protective cap, a higher valve
adapter must be used. Check compact radiators
in advance to see if they are suitable.
Thermoelectric valve drive, 230 V
Article no.
MTN639125
Function
Functions
Features
Application
Scope of delivery
Accessories
GB
1
© 2008 Schneider Electric
½Risk of fatal injury from electrical current!
All work on the device should only be carried out
by skilled electrician. Please observe the
country-specific regulations.
For the installation of a 230 V system, we recommend
the following cables:
Light plastic-sheathed cable: NYM1.5 mm²
Flat webbed cable: NYIF1.5 mm²
The valves are adjusted using a valve adapter, various
versions of which can be supplied for the most widely
used valve bodies and heating circuit distributors.
(remember when ordering)
Version de-energised closed
Voltage 230 V AC/DC,
+10%...-10%,
0 to 60 Hz
Making current max. 300 mA
for max. 200 ms
Operating current 8 mA
Operating capacity 1.8 W
Opening/closing times approx. 3 min.
Travel approx. 4 mm
Positioning force 100 N +/- 5%
Operating temperature 0 to +50 °C
Media temperature 0 to +100 °C
Storage temperature -25 to +60 °C
Ambient temperature 0 to +50 °C
Relative humidity max. 80%, non-
condensing
Type of protection/Protection class IP 54 / II
CE conformity in accordance with EN 60730
Surge protection integrated
Housing/Colour of housing polyamide/white
Weight 73 g without adapter
and connecting
cable
Connecting cable/Cable length 2 x 0.75 mm2 PVC,
grey 1 m
Notes on installation/planning
Overview of connections
Room temperature control unit
Time switch
Recommended installation positions
Valve adjustment
230 V AC
N
230 V
L
230 V
Technical data
Dimensions
44 mm 61 mm
55 mm
+5 mm
2
If you have technical questions, please contact
the Customer Care Center in your country.
www.schneider-electric.com
This product must be installed, connected and
used in compliance with prevailing standards
and/or installation regulations. As standards,
specifications and designs develop from time
to time, always ask for confirmation of the in-
formation given in this publication.
Schneider Electric Industries SAS


Produktspezifikationen

Marke: Schneider
Kategorie: Nicht kategorisiert
Modell: MTN639125

Brauchst du Hilfe?

Wenn Sie Hilfe mit Schneider MTN639125 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Schneider

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-