Saxon 8710P3 Bedienungsanleitung


Lesen Sie kostenlos die πŸ“– deutsche Bedienungsanleitung fΓΌr Saxon 8710P3 (4 Seiten) in der Kategorie Wetterstation. Dieser Bedienungsanleitung war fΓΌr 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
1
Operation Instruction
β… . Main Functions:
1. Weather forecast for 5 states: sunny, semi-sunny, cloudy, rainy, cloudburst.
2. Time display (displaying month, date, day, hour, minute, second)
3. Indication of the trend of air pressure/temperature/humidity
4. Indication of the comfort index: dry, comfortable and wet.
5. Air pressure record of 12-hour
6. Units of air pressure for choice: mb/hpa, or inHg.
7. Calculation of sunrise and sunset time of 160 cities in Europe.
8. The indoor/outdoor temperature/humidity and Max/Min record.
9. Temperature alert.
10. Dual alarms.
11. Sunrise and Sunset display
12. Time display format for choice:12/24 hour.
13. Temperature display format for choice: ℃/℉.
14. Moon phase calculated.
β…‘. Power-On or Reset
1. When Power-On or reset, LCD full displays for 3 seconds, and after a β€œBeep” it begins testing indoor temperature, humidity and air
pressure.
2. The calendar defaults 0:00:00 January 1, 2007
3. Alarm defaults 0:00.
4. The weather icon defaults semi-sunny.
β…’. Instruction of operating the KEYS
1. Key functions
Twelve functional keys: DOWN,UP, ALARM,TIME SET,LOCATION,SNOOZE,HISTORY,β–²,
β–Ό,ALERT,MAX/MIN,CHANNEL.
TIME SET
ALARM
UP
DOWN
SNOOZE
LOCATI
ON
Standard mode
Click
-----
Time
displaying /
alarm1/
Alarm2
------
Alarm on/off
-----
----
Hold
Enter into
time setting
Enter into
alarm setting
-----
-------
-----
Enter 160
cities set
Time set
Click
Confirm
the setting
-----
One step
forward
One step
backward
-----
-----
Hold
-----
-----
8steps/seco
nd forward
8steps/second
backward
-----
-----
Alarm set
Click
-----
Confirm the
setting
One step
forward
One step
backward
-----
-----
Hold
-----
-----
8steps/seco
nd forward
8steps/second
backward
-----
-----
City set
Click
-----
-----
One step
forward
One step
backward
-----
Confirm
the setting
Hold
-----
-----
8steps/seco
nd forward
8steps/second
backward
-----
-----
Channel
Alert
β–Ό
MAX/MIN
HISTORY
Standard
mode
Click
Exit RF
receiving
state/shift
channel
All the
MAX/MIN
temperature alert
on/off
Β°C/Β°F switchable
Showing the
Max value
----
Function
Operation
Function
Operation
2
Hold
Enter into
RF
registering
state
Enter into
temperature alert
setting
-----
Enter into
snooze state
Enter 160
cities set
Temperature set
Click
Choose the
channel
need to be
set
Confirm the
setting
One step
backward
-----
-----
Hold
-----
-----
8steps/second
backward
-----
-----
Height
set
Click
-----
-----
One step
backward
-----
-----
Hold
-----
-----
8steps/second
backward
-----
-----
TIME SET Key:
Hold β€œTIME SET” key for 2 seconds to enter into time setting mode, the sections being set will flash in the frequency of 1 Hz/second,
press β€œUP” or β€œDOWN”to choose the value needed then press β€œTIME SET” key to confirm the setting.
It will return to standard mode automatically, if there is no operation for more than 7 seconds.
ALARM Key
Click β€œAlarm” key to display alarm time, press once to display AL1; twice for Al2; thrice to return to standard state. Hold β€œAlarm” key
for 2 seconds to enter alarm setting, the sequence: AL1/ AL2 Hour Minute Exit.
It will return to standard mode automatically, if there is no operation for more than 7 seconds.
UP Key
Under setting mode, click β€œUP” Key to adjust one step (forward), holding the β€œUP” Key for 2 seconds to enter speedy adjusting mode (8
steps/seconds).
DOWN Key
Under setting mode, click β€œDOWN” Key to adjust one step (backward), holding the β€œDOWN” Key for 2 seconds to enter speedy
adjusting mode (8 steps/seconds).
Under standard mode, Click β€œDOWN” Key to turn alarm on/off, the setting sequence: AL1 on/ AL2 off οƒ  AL2 on/ AL1 off οƒ  AL1,
AL2 on οƒ  AL1, AL2 off.
SNOOZE Key
When the alarm is ringing, click β€œSNOOZE” key to pause the alarm, and enter 5 minutes of snooze function.
LOCATION Key
Under standard mode, hold the β€œLOCATION” key for 2 seconds to enter city setting.
Under city setting state, hold β€œUP” or β€œDOWN” key to choose the city, and then click β€œLOCATION” key to confirm the setting and exit
the state.
CHANNEL Key
Under standard mode, click β€œChannel” key to shift RF channel, CH1οƒ CH2 οƒ  CH3οƒ displaying circularly.
Under standard mode, hold β€œChannel” Key for 2 seconds to clean out RF registering state, temperature displays and MAX/MIN value.
Under Alert setting channel state, choose the needed setting channel..
MAX/MIN Key
Click β€œMax/Min” key to display MAX value of indoor/outdoor temperature, humidity for 5 seconds. Click once again to display the
MIN values for 5 seconds, click again to return to standard mode.
When it displays the Max or Min values, hold Max/Min key for 2 seconds to clear out the memory of the Max/Min values, then return to
normal standard state.
ALERT Key
Under standard mode, click Alert key to turn temperature alert on/off.
Under standard mode, hold Alert key for 2 seconds, it will enter temperature alert setting.
3
Under temperature alert setting mode, click Alert key to confirm the setting items, the sequence: channelsetting the Maxsetting the
Min.
β–²Key
Under standard mode, click β–² to choose the unit of air pressure: Hpa/Mb or inHg.
Under setting mode, click once to go forward one step/second, hold for 2 seconds to go forward 8 steps/second.
β–ΌKey
Under standard mode, click to choose the unit of temperature between Β°C/Β°F.
Under setting mode, click to go backward one step, hold for 2 seconds to go backward 8 steps/second.
HISTORY Key
Under standard mode, clicking to check the air pressure record of past 12 hours.
RF Receiving Mode
1. After power-on and finishing testing temperature, humidity and air pressure, it enters RCC receiving state for 3 minutes. Under
standard mode, hold CH key for 3 seconds to enter RF receiving mode. If there is no new effective signal from sensors in 60 minutes,
the outdoor temperature of that CH will display β€œ----”.
2. The outdoor temperature will display valid value of that CH from β€œ----” when the main unit detects and receives the correct signal
from that CH again.
3. Hold β€œCHANNEL”, it displays CH1-->CH2-->CH3-->auto recycling (5 seconds a shift).
TIME MODE
1. The default time after power-on is 2007.1.1, 0:00:00, the range of perpetual calendar 2000-2099.
2. Under standard mode, hold β€œTIME SET” key for 2 seconds to enter time setting mode.
3. Under setting mode, press β€œUP” or β€œDOWN” key to adjust the data of items to be set, click β€œTIME SET” to confirm the data.
4. Under setting mode, the items being set will flash in the frequency of 2Hz/second, the setting sequence: year monthdate
language12/24HRhour minutetime zoneexit.
5. If there is no valid operation on the key after 7 seconds, it will exist the setting mode, but the items set will be kept. The valid keys
include β€œTIME SET”, β€œUP”, β€œDOWN”.
ALARM ALERT MODE
1. Under standard mode, click β€œALARM” to view the Alarm time, the sequence: AL1, AL2, Normal.
2. Under standard mode, click β€œUP” key to switch the alarm ON/OFF, the sequence: AL1 ON, AL2 OFFοƒ AL1 OFF, AL2 ONοƒ AL1
ON, AL2 ONAL1 OFF, AL2 OFF.
3. Under ALARM time displaying mode, hold β€œALARM” key for 2 seconds to enter ALARM setting mode.The setting sequence:
AL1/AL2hour settingminute settingexist setting mode.
4. During the setting, click β€œUP” or β€œDOWN” key to adjust the items to be set, and click β€œALARM” key to confirm the items.
5. If there is no effective operation on the key after 8 seconds, it will exit the setting mode, but the items set will be kept. The effective
keys include β€œALARM”, β€œUP”, β€œDOWN”.
6. Alarm ringing for 2 minutes totally ,and Alarming format::
(1) 0~10 seconds: one Beep/second;
(2) 10~20 seconds: two Beeps/second;
(3) 20~30 seconds, three Beeps/second;
(4) After 30 seconds, Beeping continuously.
The alarm is switched on after set.
CITY SETTING
1. Under standard mode, hold β€œLOCATION” key for 2 seconds to enter location setting and choose the city you stay (there are 160
European cities for selection).
2. Click β€œUP” or β€œDOWN” to choose, and click β€œLOCATION” key to confirm.
SUNRISE / SUNSET , MOON PHASE AND TIDE
1. The unit will calculate automatically the time of sunrise/sunset of the city everyday after the city is selected.
2. It will calculate moon phase and tide ebb/ flux every day according to the calendar. There are 8 states of moon phase and 3
step(H,M,L) of tide in all
THERMOMETER AND HYGROMETER
1. The indoor temperature range: 0Β°C-50Β°C (32Β°F-122Β°F), and the outdoor temperature range: -50Β°C-70Β°C (-58Β°F-158Β°F).
2. Humidity range: 20%-95%.
AIR PRESSURE AND WEATHER REPORT MODE


Produktspezifikationen

Marke: Saxon
Kategorie: Wetterstation
Modell: 8710P3

Brauchst du Hilfe?

Wenn Sie Hilfe mit Saxon 8710P3 benΓΆtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Wetterstation Saxon

Bedienungsanleitung Wetterstation

Neueste Bedienungsanleitung fΓΌr -Kategorien-