S-1 / S-2 / S-3
MAGNETIC CONTACT
s123_en 08/19
The S-1 / S-2 / S-3 magnetic contact can detect opening of a door, window, etc. Additionally, it is
provided with a tamper loop. The S-1 magnetic contact is designed for surface mounting, and the S-2
and S-3 magnetic contacts – for flush mounting.
1. Description
The device consists of a contact (reed switch) and a magnet. Moving the magnet away from the
contact (opening the door or window) opens the reed switch contacts (thus triggering alarm).
Both magnetic contact elements are placed in identical waterproof enclosures. The S-1 and S-2
enclosures are made of plastic, while the S-3 enclosure is made of metal. The contact has 4 wires.
The two twisted wires are a tamper loop. The contacts are shown in the figures below.
2. Installation
The contact should be mounted on a fixed surface (e.g. window or door frame), and the magnet on
a movable surface (e.g. window or door). Do not install the magnetic contact on ferromagnetic
surfaces and near to strong magnetic and electrical fields, because it can result in malfunctioning of
the device. When mounting the magnetic contact, you must take into account the make distance.
The S-1 magnetic contact is designed for surface mounting. Place the contact and magnet in parallel
next to each other (Fig. 4). The magnetic contact elements can be attached with screws, double-sided
tape or glue.
The S-2 and S-3 magnetic contacts are designed for flush mounting in wood or plastic. Place the
contact and magnet facing each other (Fig. 5 – as shown by the example of S-3). To make holes for
2 S-1 ï‚· ï‚· S-2 S-3 SATEL
the magnetic contact elements, use a ø9 mm drill. Press the S-2 magnetic contact elements or screw
the S-3 magnetic contact elements into the holes made.
Notes:
ï‚· Do not use a hammer to drive the contact into the hole (it may damage the reed switch).
ï‚· When screwing the S-3 contact into the hole, the wires become twisted. To prevent them from
damage, twist the wires against the direction of screwing before installation.
magnet.
contact.
A – make distance.
B – permissible offset between contact and magnet axes: S-2 = 10 mm, S-3 = 12 mm.
C – minimum thickness of the wall in which magnetic contact elements can be mounted: 10 mm.
3. Specifications
Magnetic contact type......................................................................................................................... NC
Maximum switching voltage.............................................................................................................. 20 V
Maximum switching current ........................................................................................................... 20 mA
Contact resistance.......................................................................................................................150 mΩ
Minimum life expectancy (20 V, 20 mA) ......................................................................................360 000
Contact material ...............................................................................................................Ru (ruthenium)
Make distance S-1................................................................18 mm
S-2................................................................28 mm
S-3................................................................15 mm
Break distance S-1................................................................28 mm
S-2................................................................40 mm
S-3................................................................24 mm
Environmental class according to EN50130-5........................................................................................II
Operating temperature range ............................................................................................ -10°C...+55°C
Maximum humidity........................................................................................................................ 93±3%
Weight S-1....................................................................29 g
S-2....................................................................28 g
S-3....................................................................43 g
The declaration of conformity may be consulted at www.satel.eu/ce
SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gdańsk • POLAND
tel. +48 58 320 94 00
www.satel.eu
Produktspezifikationen
Marke: | Satel |
Kategorie: | Tür-/Rahmensensor |
Modell: | S-3 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Satel S-3 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Tür-/Rahmensensor Satel
21 August 2024
19 August 2024
17 August 2024
Bedienungsanleitung Tür-/Rahmensensor
- Tür-/Rahmensensor Hama
- Tür-/Rahmensensor Bosch
- Tür-/Rahmensensor Schwaiger
- Tür-/Rahmensensor EMOS
- Tür-/Rahmensensor König
- Tür-/Rahmensensor Caliber
- Tür-/Rahmensensor Abus
- Tür-/Rahmensensor Avidsen
- Tür-/Rahmensensor EZVIZ
- Tür-/Rahmensensor Olympia
- Tür-/Rahmensensor Nexa
- Tür-/Rahmensensor Marmitek
- Tür-/Rahmensensor Techly
- Tür-/Rahmensensor Chamberlain
- Tür-/Rahmensensor Kidde
- Tür-/Rahmensensor Optex
- Tür-/Rahmensensor Speed-Link
- Tür-/Rahmensensor Hikvision
- Tür-/Rahmensensor Homematic IP
- Tür-/Rahmensensor Interlogix
- Tür-/Rahmensensor KlikaanKlikuit
- Tür-/Rahmensensor Steren
- Tür-/Rahmensensor X4-Tech
- Tür-/Rahmensensor Sonoff
- Tür-/Rahmensensor Inovonics
- Tür-/Rahmensensor Axis
- Tür-/Rahmensensor Fibaro
- Tür-/Rahmensensor ORNO
- Tür-/Rahmensensor DSC
- Tür-/Rahmensensor Tellur
- Tür-/Rahmensensor Kanlux
- Tür-/Rahmensensor Gewiss
- Tür-/Rahmensensor Setti+
Neueste Bedienungsanleitung für -Kategorien-
7 Oktober 2024
18 September 2024
13 September 2024
13 September 2024
6 September 2024
6 September 2024
5 September 2024
5 September 2024
5 September 2024
5 September 2024