Pyle PMX802M Bedienungsanleitung

Pyle Stabmixer PMX802M

Lesen Sie kostenlos die šŸ“– deutsche Bedienungsanleitung fĆ¼r Pyle PMX802M (9 Seiten) in der Kategorie Stabmixer. Dieser Bedienungsanleitung war fĆ¼r 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/9
Mulī‡‚-Channel Mixers
PyleUSA.com
Warnings
ļ‚· Please be sure to read, keep and refer to instrucī‡‚ons listed in this manual.
ļ‚· Do not use this device near water or expose to moisture.
ļ‚· Clean only with a dry cloth.
ļ‚· Do not block any venī‡‚laī‡‚on openings and allow adequate space for air ī…øow during operaī‡‚on.
ļ‚· Do not install near any heat sources or other devices that produce heat.
ļ‚· Do not defeat the safety purpose of the polarized or grounding-type plug.
ļ‚· Protect the power cord from any kind of damage or corrosion.
ļ‚· Unplug the mixer when not in use or when unused for long periods of ī‡‚me.
ļ‚· Refer all service to qualiī…Ÿed service personnel. Servicing is required when the mixer has been damaged or performs in an unusually.
ļ‚· Use only speaker cables when connecī‡‚ng speakers to ampliī…Ÿer outputs. Using other types of cables is a ī…Ÿre hazard.
ļ‚· Exposure to extremely high noise levels may cause in permanent hearing loss. Individuals vary considerably to noise induced hearing loss but
take precauī‡‚on when listening at high levels.
ļ‚· If the power cord is damaged (i.e., cut or a bare wire is exposed), ask your dealer for a replacement. Using the unit with a damaged power cord
is a ī…Ÿre and electrical shock hazard.
ļ‚· Should this unit be dropped or the cabinet be damaged, turn the power switch oī…œ, remove the power plug from the AC outlet, and contact your
dealer. If you conī‡‚nue using the unit without heeding this instrucī‡‚on, ī…Ÿre or electrical shock may result.
C A U T I O N
If the unit is damaged or non-operaī‡‚onal, please noī‡‚fy your dealer and the shipping company immediately. Claims for
damage or replacement may not be granted if not reported properly or in a ī‡‚mely manner.
ļ‚· Connect this unitā€™s power cord only to an AC outlet of the type stated in this Manual or as marked on the unit. Failure to do so may result in
ī…Ÿre and/or electrical shock.
ļ‚· Do not place heavy objects on top of the power cord. A damaged power cord is also a ī…Ÿre and electrical shock hazard.
ļ‚· Use only the included power cord for this unit, using other types may again result in ī…Ÿre and electrical shock.
ļ‚· Do not set all equalizer controls and faders to maximum levels. Doing so may cause oscillaī‡‚on depending on the condiī‡‚on of the connected
unit and speakers, and may also damage the speakers.
ļ‚· The performance of components on this mixer such switches, rotary controls, faders, and connectors, deteriorates over ī‡‚me. The rate as
depends on the operaī‡‚ng environment and is someī‡‚mes unavoidable. Consult your dealer about replacing defecī‡‚ve components.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT ATTEMPT TO OPEN OR ACCESS THE INSIDE OF
THE UNIT. REFER ALL SERVICING TO A QUALIFIED PYLE
SERVICE PERSONNEL.
This lightning ī…øash symbol is intended to alert the user to the presence of uninsulated and ā€œdangerous
voltageā€ within the mixer's enclosure that may be of suī…‘cient power to consī†¬tute a risk of electric shock.
This exclamaī‡‚on point symbol is intended to alert the user to the presence of important operaī‡‚ng
and maintaining instrucī‡‚ons, that one should pay aī‡Œenī‡‚on to and keep for future reference.
Mulī†¾-Channel Mixers
PyleUSA.com
Installaī†µon
Install the mixer on an even surface to allow for suī…„cient airī…“ow and venī†¾laī†¾on during use. The device is equipped with
electronically controlled cooling fans to protect against thermal overload and internal circuitry from damage due to
extreme heat. Please avoid covering any sides of the unit or placing objects or other audio devices too close to your mixer.
Prior to connecī†¾ng and powering on the unit, make sure that the device matches the voltage and frequency of your
power supply. Power oī…˜ the mixer when not in use.
Cables and Connecī†µons
RCA
1/4'' TRS and Mono
XLR 3-Pin
RCA connector jacks have been most
commonly used in home audio systems
and conī…›guraī†¾ons for years. Also known
as RCA 'phono', 'plugs' or 'audio
connectors' , these jacks are always
unbalanced, and generally carry a line-
level signal at 10 dB, nominal signaā€“l
levels. The RCA connector jacks are most
likely used when connecī†¾ng an audio
device like a media player or other home
audio type source to your mixer. These
connector jacks are also used when
connecī†¾ng to the output of your devices.
1/4'' mono and stereo connector jacks are
labeled for use as unbalanced mono,
unbalanced stereo, balanced mono, or as
an insert patch point. A 1/4'' TRS (Tip,
Ring, Sleeve), 3-conductor connecī†¾on, or
'Stereo' cable allows a single connecī†¾on
signal to carry 2-channels of audio; also
can be used for mono balanced signals.
While, a 1/4'' TS (Tip, Sleeve), 2-conductor,
or 'Mono' cable are most popularly known
for their use in guitar or line-level
instrument connecī†¾on; they can also be
used for mono unbalanced signals.
XLR connector jacks, almost always carries
a balanced signal. Depending on your
device, these connector jacks may also be
capable of handling unbalanced signals.
Microphones generally have this type of
connector, as well as most other
professional audio equipment and devices.
Typical 3-Pin XLR sockets are ī…›xed with the
right-most pin being the 'ground', the leī…¹-
most pin being 'hot' and the boī‡ˆom pin
as the 'neutral'.
Technical Speciī…‘caī†µons
Mono Inputs
Microphone Inputs (XENYX Mic Preamp)
XLR, electronically balanced, discrete input circuit
Mic E.I.N. (20Hz - 20kHz)
@ 0 Ohm Source Resistance
@50 Ohm Source Resistance
@150 Ohm Source Resistance
-134dB / 135.7dB A-Weighted
-131dB / 133.3dB A-Weighted
-129dB / 130.7dB A-Weighted
Frequency Response
<10Hz - 150kHz (-1dB)
<10Hz - 200kHz (-3dB)
Gain Range
+10dB to +60dB
Maximum Input Level
+12dB @ +10dB Gain
Impedance
Approximately 2.6k Ohm, Balanced
Signal- -Noise to
110dB / 112dB A-Weighted
Distorī†µon (THD +N)
0.005% / 0.004%, A-Weighted
Line Input
1/4'' TRS Connectors, Electronically Balanced
Channel Equalizaī†µon
(Frequency Hz)
Control Range High: @ 10k +/-15dB
Control Range Low: k +/-15dB @60
Master 5-Band Graphic EQ
Frequency: Hz (60, 250, 1K, 4K, 12K)
Control Ranges: +/-12dB


Produktspezifikationen

Marke: Pyle
Kategorie: Stabmixer
Modell: PMX802M

Brauchst du Hilfe?

Wenn Sie Hilfe mit Pyle PMX802M benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Stabmixer Pyle

Bedienungsanleitung Stabmixer

Neueste Bedienungsanleitung fĆ¼r -Kategorien-