Projecta BLT200 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Projecta BLT200 (4 Seiten) in der Kategorie Ladegerät. Dieser Bedienungsanleitung war für 10 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
CAUTION- BATTERIES PRODUCE EXPLOSIVE GASES,
TO REDUCE THE RISK OF EXPLOSION OR INJURY
ALWAYS ENSURE:
• No sparks or ames are present
• Eye protection is worn
• All vehicle or battery manufacturers instructions are followed
• The load is ‘OFF’ before connection or disconnection
• Correct Polarity, do not reverse connect
• Beware of moving engine parts
NOTE
Carbon pile load testers produce a great amount of heat while the load is ‘ON’,
do not apply the load for more than 20 seconds at a time and allow time to cool
between tests.
When operating the unit for the rst time it is normal for a small amount
of smoke to develop as the lubricants used in the manufacturing process burn off.
SPECIFICATIONS
Tests: Volts (0-16VDC)
12V Lead Acid Batteries
12V Charging systems
(Alternators & Regulators)
Battery Range: Up to 1000CCA (160Ah)
Test Load: Adjustable Carbon Pile
0 - 500 AMPS
Maximum Load ‘ON’ Time: 20 Seconds
Recommended Cool
Down Time: 2 Minutes
Test time alert: Buzzer sounds after 15 seconds
Cable length: 1000mm
Size: 267mm x 230mm x 92mm
Weight: 3.5kg
Operating Instructions
Battery Load Test
1. Connect the RED clamp to the Positive (+) battery terminal or post.
2. Connect the BLACK clamp to the Negative (-) battery terminal or post.
Note: If testing a battery in the vehicle, ensure the engine and all loads areOFF’.
3. Check the batterys open circuit voltage (OCV) on the DC Volt meter.
- If the needle is in the green section of the ‘State of Charge’ scale (above 12.5V)
the battery has sufcient charge to test.
- If the needle is in the red section (below 12.5V) the battery needs to be fully
charged before testing.
4. Determine the batterys rated capacity in Cold Cranking Amps (CCA) or
Amp Hours (Ah) and calculate the correct load current:
Cranking Batteries: Load current = 1/2 the CCA rating
Deep Cycle Batteries: Load current = 3 x Ah rating
5. Turn the ‘Load Control Knobclockwise until the correct load current is reached
on the DC Amps meter.
6. After 15 seconds the buzzer will sound to indicate the correct test time,
immediately read the DC Volt meter.
- If the needle is in the Green area of the ‘Battery Test’ scale the battery has
passed the test.
- If the needle is in the red area the battery has failed the test, quickly reduce
the load current until the needle moves back into the green area, and then read
the approximate battery capacity in Ah or CCA from the DC Amps meter.
ONCE THE METER HAS BEEN READ THE LOAD MUST BE TURNED OFF
IMMEDIATELY TO PREVENT OVERHEATING - TURN THE LOAD CONTROL
KNOB FULLY ANTI-CLOCKWISE.
Note: Battery output varies due to temperature change, the ‘Battery Test’ scale has
4 temperature calibrations (21º, 10º, -1º & -18º Celcius) Use the closest scale to the
approximate ambient temperature.


Produktspezifikationen

Marke: Projecta
Kategorie: Ladegerät
Modell: BLT200

Brauchst du Hilfe?

Wenn Sie Hilfe mit Projecta BLT200 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Ladegerät Projecta

Bedienungsanleitung Ladegerät

Neueste Bedienungsanleitung für -Kategorien-