EH1419
7.3 kW (25000 BTU/hour)
Mobile Industrial Spot Cooler
Spot Cooling
LED display panel
4 Hour timer
Page 2
IMPORTANT
Installer and Users please note:
These instructions should be read carefully and left with the
user of the product for future reference.
BEFORE USE
Inspect the product including its cable and plug for any signs
of damage. If the product is damaged, DO NOT use it, and
contact your supplier immediately. The appliance contains a
refrigerant gas, so must be kept upright at all times. After
unpacking wait 3 hours for the refrigerant gas to stabilise
before use.
INSTALLATION
Attach the two handles to the rear
panel of the appliance. Remove the
four screws from the top left and right
sides of the rear panel.
Use the screws to fix the handles to
the rear panel.
The handles allow the appliance to
be moved more easily, and prevent it
from being damaged.
Attach the flexible tubes to the
apertures on the front panel of the
appliance, using the M5 countersunk
screws provided.
The EH1419 will operate with the
greatest efficiency if it is situated
outside the area to be cooled, and
the cold air ducted in using the two
flexible tubes.
Page 3
Stand the EH1419 on a firm, flat, level surface, and apply the
brakes to the rear castors.
For industrial spot cooling, no hot air ducting is required.For
zone cooling use 18" (457 mm) ducting. Never use reducers,
as they cause the exhaust air to be compressed, generating
heat, reducing efficiency, and reducing the output of cooled
air.
The appliance collects condensed water in the tank, so the
exhaust air is dry, and may be vented into a false ceiling.
GENERAL SAFETY REQUIREMENTS
Domestic wiring must be tested periodically by a qualified
electrician at least once every 10 years or at every change of
occupancy.
For office and retail premises, and buildings such as village
halls, the wiring must be inspected at least once every 5
years.
It is recommended that all building be fitted with smoke
alarms (it is mandatory for new buildings).
PAT TESTING.
When used in an office or commercial environment, this
product must be safety-tested yearly by a qualified electrician
(PAT Tested) in order to comply with the Electricity at Work
Regulations. If hired out, it should be PAT tested before
every hire.
We recommend that it is PAT tested regularly when used in
a domestic environment.