Prem-i-air EH0554 Bedienungsanleitung

Prem-i-air Airco EH0554

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Prem-i-air EH0554 (12 Seiten) in der Kategorie Airco. Dieser Bedienungsanleitung war für 17 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/12
EH0554
Indoor Climate Control
3.2kW heating or cooling capacity
Air conditioning
Dehumidification
Cooling
Efficient heating via air-source heat-pump
Suitable for high- or low-wall installation
No external unit required
Page 1
IMPORTANT
Installer and Users please note:
These instructions should be read carefully and left with the user of
the product for future reference.
BEFORE USE
Inspect the product including its cable and plug for any signs of
damage. If the product is damaged, DO NOT use it, and contact
your supplier immediately.
Check that the following items are included:
Page 2
INSTALLATION
The appliance weighs 42kg. In order to comply with Health and
Safety Manual Handling guidelines, two people will be required to
lift it.
Transport and store in an upright position. Leave the unit in an
upright position for at least 3 hours before first use.
Choose the optimum location for the
appliance:
It must be on an external wall with 2m
free clearance on both inside and
outside to allow good airflow
The wall must be able to withstand
the weight of the unit.
The wall must be perfectly flat.
There must be no electrical wiring,
gas pipes, or structural steelwork in
the wall in the area where the
appliance is to be mounted.
Attach the template to the wall using masking tape. Use a spirit
level to ensure that it is perfectly level.
Drill the fixing holes and insert wall plugs.
Using a 135mm core drill, drill the two air intake holes. These
should be drilled with a downwards
slope of between 3° and 5° to make
sure that any water will drain out.
Using a 30mm masonry bit, or a core
drill, drill the hole for the water drain.
This MUST have a downward slope
of between 3° and 5° to make sure
that the water will drain out.
Cut the air intake tubes so that they are 10mm less then the
thickness of the wall. Attach the flanges for the air intake and
exhaust tubes to the tubes using the 10 mm screws provided.
Then fix the tube/flange assembly into the hole. If the outside wall
is accessible, fill the area between the tubes and the wall using
expanding foam, and attach the rubber rings to the outside of the
Page 3

Produktspezifikationen

Marke: Prem-i-air
Kategorie: Airco
Modell: EH0554

Brauchst du Hilfe?

Wenn Sie Hilfe mit Prem-i-air EH0554 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Airco Prem-i-air

Bedienungsanleitung Airco

Neueste Bedienungsanleitung für -Kategorien-