POLARIS Forza Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für POLARIS Forza (36 Seiten) in der Kategorie pomp. Dieser Bedienungsanleitung war für 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/36
H0752600_REVC
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state/
provincial or local requirements exist. The maintainer must be a professional with sufficient experience in
pool equipment installation and maintenance so that all of the instructions in this manual can be followed
exactly. Before installing this product, read and follow all warning notices and instructions that accompany
this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation may void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which
can cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the
installation, operation and safe use of this product. This information should be given
to the owner/operator of this equipment.
DO NOT MODIFY THIS EQUIPMENT
Above Ground Pump
PAG100, PAG100T
PAG150, PAG150T
Owner’s Manual
ENGLISH | FRANÇAIS | ESPAÑOL
Page 2 ENGLISH
Polaris® Forza™ Pump
|
Owner's Manual
DATE OF INSTALLATION
INSTALLER INFORMATION
INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)
PUMP MODEL HORSEPOWER
NOTES:
EQUIPMENT INFORMATION RECORD
Table of Contents
Section 1. Important Safety Instructions 3 ........
1.1 Pool Pump Suction Entrapment
Prevention Guidelines 5 ........................................
Section 2. Installation 6 .......................................
2.1 Installation Location 6 ...........................................
2.2 General Connections 6 .........................................
2.3 Pump Plumbing 6 .................................................
2.4 Electrical Data 6 ....................................................
2.5 Bonding and Grounding 7 .....................................
Section 3. Pump Start Up 7 .................................
3.1 Priming ............................................................... 7
3.2 Startup ................................................................ 7
3.3 Single-Speed Pumps 7 ..........................................
Section 4. Winterizing 8 ......................................
4.1 Water Chemistry 8 ................................................
4.2 Pump Maintenance 8 ............................................
Section 5. Service & Repair Parts 8 ..................
Section 6. Troubleshooting 9 .............................
Section 7. Technical Data 9 ................................
Page 3
ENGLISH
Polaris® Forza™ Pump | Owner's Manual
Section 1. IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
All electrical work must be performed by a licensed electrician or qualiîš¿ed pool service professional and conform to all
national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should
always be followed, including the following:
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN SERIOUS INJURY
OR DEATH. Do not block pump suction, as this can cause severe injury or death. Do not use this pump for wading
pools, shallow pools, or spas containing bottom drains. Suction outlet (drain) assemblies and their covers must be
certied to the latest published edition of ANSI®/ASME® A112.19.8, or its successor standard, ANSI/APSP-16.
WARNING
To reduce the risk of injury, do not permit children to use this product. All components in the system, such as
pumps, îš¿lters, and heaters, etc., shall be positioned so as to prevent their being used as a means of access to the
pool by young children.
WARNING
To reduce the risk of property damage or injury, do not attempt to change the backwash (multi-port, slide, or full
ow) valve position with the pump running.
WARNING
Polaris pumps are powered by a high voltage electric motor and must be installed by a licensed or certiîš¿ed
electrician or a qualiîš¿ed swimming pool service technician.
WARNING
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH. Connect only to a grounding type
receptacle that is protected by a ground-fault circuit-interrupter (GFCI) (Canada: CLASS A). Contact a qualiîš¿ed
electrician if you cannot verify that the circuit is protected by a GFCI. Make sure such a GFCI should be provided
by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should
interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the
GFCI is defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current
is owing, indicating the possibility of electrical shock. Do not use the pump. Disconnect the pump and have the
problem corrected by a qualiîš¿ed service representative before using.
Due to the potential risk of îš¿re, electric shock, or injuries to persons, Polaris pumps must be installed in
accordance with the National Electrical Code® (NEC®), Canadian Electrical Code (CEC), all local electrical and
safety codes, and the Occupational Safety and Health Act (OSHA ®). Copies of the NEC may be ordered from the
National Fire Protection Association® (NFPA®) online at www.nfpa.org or call 617-770-3000, or contact your local
government inspection agency.
WARNING
Incorrectly installed equipment may fail, causing severe injury or property damage. DO NOT MODIFY THIS
EQUIPMENT.
WARNING
To reduce the risk of electric shock, replace damaged cord immediately. If replacement of the plug or cord is
needed, use only identical replacement parts. To reduce the risk of electric shock, do not use extension cord to
connect unit to electric supply; provide a properly located outlet.
WARNING
• Do not connect the system to an unregulated city water system or other external source of pressurized water
producing pressures greater than 35 PSI.
• Trapped air in system can cause the lter lid to be blown off, which can result in death, serious personal injury, or
property damage. Be sure all air is out of the system before operating.
Produktspezifikationen
Marke: | POLARIS |
Kategorie: | pomp |
Modell: | Forza |
Brauchst du Hilfe?
Wenn Sie Hilfe mit POLARIS Forza benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung pomp POLARIS
13 August 2024
12 August 2024
8 August 2024
Bedienungsanleitung pomp
- pomp Crivit
- pomp SilverCrest
- pomp SKS
- pomp Makita
- pomp Vonroc
- pomp Siemens
- pomp Powerfix
- pomp Black And Decker
- pomp Ryobi
- pomp Coleman
- pomp Einhell
- pomp Worx
- pomp Bartscher
- pomp Ultimate Speed
- pomp Eheim
- pomp Eurom
- pomp Hyundai
- pomp Fuxtec
- pomp Hazet
- pomp Metabo
- pomp Kärcher
- pomp Güde
- pomp Scheppach
- pomp Fieldmann
- pomp Wetelux
- pomp Westfalia
- pomp Vaillant
- pomp Husqvarna
- pomp Enermax
- pomp MSW
- pomp Germania
- pomp Fluval
- pomp Vetus
- pomp Jabsco
- pomp Sanibroyeur
- pomp Topeak
- pomp Hayward
- pomp Gre
- pomp Milwaukee
- pomp Toolcraft
- pomp Osram
- pomp Bestway
- pomp AL-KO
- pomp Gardena
- pomp Melinera
- pomp Powerplus
- pomp Blackburn
- pomp Lezyne
- pomp Alpha Tools
- pomp Sicce
- pomp Bulex
- pomp Danfoss
- pomp Comet
- pomp Hozelock
- pomp Ozito
- pomp Blumfeldt
- pomp Nibe
- pomp Sun Joe
- pomp Fluke
- pomp Nefit
- pomp Oase
- pomp Velda
- pomp Vivaria
- pomp Waldbeck
- pomp WHALE
- pomp AstralPool
- pomp Pedrollo
- pomp Esotec
- pomp T.I.P.
- pomp Panduit
- pomp Heissner
- pomp DAB
- pomp Abac
- pomp Baracuda
- pomp Ubbink
- pomp JANDY
- pomp Liberty Pumps
- pomp Monzana
- pomp Lifan
- pomp Elpumps
- pomp For_Q
- pomp Simpson
- pomp Pontec
- pomp BluGarda
- pomp Grundfos
- pomp Zoeller
- pomp B-Air
- pomp Anova
- pomp Perlick
- pomp Fiap
- pomp Little Giant
- pomp Ebara
- pomp Basement Watchdog
- pomp Barwig
- pomp Wayne
- pomp Ribimex
- pomp Maruyama
- pomp ESPA
- pomp Hollex
- pomp Sauermann
- pomp Eco-Flo
- pomp Nowax
- pomp EvoHeat
- pomp Zéfal
- pomp OSIP
- pomp Franklin Electric
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
13 Oktober 2024
7 Oktober 2024
2 Oktober 2024
1 Oktober 2024