Manual
Infrared Thermometer
Hi Temp 2400
Ref.No.062010
5
50
02
20
0-
-2
24
40
00
0
O
Op
pe
er
ra
at
ti
in
ng
g
I
In
ns
st
tr
ru
uc
ct
ti
io
on
ns
s
For Model with thermocouple socket
The non-contact infrared thermometer is the ultimate tool for temperature measurements. It can measure from 200 to 2400
(392 to 4352 oF) in the distance of 100:1 DS (Distance to Spot) ratio. Furthermore, the memory mode can record and display the
specific measurement with emissivity. There are many mathematical modes for the Infrared function.
* Please remember to keep away from children and don’t use it for safety related applications.
(Default Screen)
Simply aim the
thermometer at the
measure target with
Lens ( ,11 ) and
press Meas. key (,8)
to display the surface temperature. The Distance:Spot is 100:1. The two laser points are the
reference for the target spot size. Please make sure the target area is within the field of view.
FUNCTION
Press Emissivity key (,2) for setting the emissivity
Press Emissivity key (,2), then press Up key (,4) or Down key (,2) to set the emissivity, then press Mode
key (,5) to confirm it. The emissivity can be changed from 0.10 (10E) to 1 (100E).
Press Mode key (,5) for scrolling more display function as follows.
Here will show the emissivity data. (The default emissivity is 0.95.)
Press Mode key (,5) for the Maximum (MAX), Minimum (MIN), Different between MAX and MIN (DIF) and
Average (AVG) modes. During the measurement, the special modes reading will be displayed beside the
mode icon.
Press Up key (,4) or Down key (,2) key to change the High Alarm (HAL) or Lo Alarm (LAL), then press
Meas. key (,8) to confirm it. For example: When the reading 26.9oC < LAL 27 oC, the Low icon will flash and you
will hear a beep sound.
Connect the thermocouple with Thermocouple socket (,7) and put the probe in/on the target, the thermometer
will display the temperature automatically without pressing any button. To see the minimum or maximum data
during the probe measurement, please hold down the Up key (,4) or Down key (,2).
After measure high temp, the probe may remain HOT for a while.
After taking the temperature, press Mode key (,5) for the Memory (M00), then press Meas. key (,8) to save
the measurement. Under the Memory (M00) , press Up key (,4) or Down key (,2) key to display the record.
** The thermometer will automatically shut off if left idle for more than 60sec.ADD VALUE
In MAX, MIN, DIF,
AVG mode:
In all modes: First
hold on the Meas.
key (,8)
and press Up key (,4) for backlight function ON/OFF
and press Down key (,2) for laser function ON/OFF.
(With flash light be turned on in the same time as laser )
CAUTION
1. WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE TWO LASER BEAMSPERMANENT EYE DAMAGE MAY RESULT.
2. USE EXTREME CAUTION WHEN OPERATING THE LASER.
3. NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.
4. KEEP OUT OF REACH OF ALL CHILDREN.
STORAGE & CLEANING
It should be stored at room temperature. The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times,
care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. Allowing the lens to fully dry
before using the thermometer. Do not submerge any part of the thermometer.
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
Hi or Lo is displayed when the temperature being measured is outside of the settings of HAL and LAL.
「 」
‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature. ‘Er3’
is displayed when the ambient temperature exceeds 0oC (32°F) or +50oC (122°F). The thermometer
should be allowed plenty of time (minimum 30 minutes) to stabilize to the working/room temperature.
Error 5~9, for all other error messages it is necessary to reset the thermometer. To reset it, wait for auto power
off, remove the battery and wait for a minimum of one minute, reinsert the battery and turn on. If the error
message remains please contact the Service Department for further assistance.
」「
Hi or Lo is displayed when the temperature being measured is outside of the measurement range.
BATTERIES
The thermometer incorporates visual low battery indication as follows:
Battery OK: measurements
are possible
Battery Low: battery needs to be
replaced, measurements are still possible
Battery Exhausted: measurements are not
possible
When the Low Battery icon indicates the battery is low, the battery should be replaced immediately with AAA, 1.5V batteries. Please note: It
is important to turn the instrument off before replacing the battery otherwise the thermometer may malfunction.
Dispose of used battery promptly and keep away from children.
SPECIFICATION
Item
Non-contact Infrared Scan function
Thermocouple Probe Scan function
(K type; probe not included.)
Measurement Range
200.. +2400 oC (392 .. +4352 oF)
-64 to +1400°C (-83.2 to +2552°F)
Operating Range
0 to +50°C (32 to +122°F)
Emissivity Range
0.95 default adjustable 0.1 to 1 step .01
Resolution
0.1°C/0.1°F at -83.2 to 999.9(°C/°F), otherwise 1°C/1°F
Response Time (90%)
1 sec.
Distance:Spot
100:1
Memory
Detailed 24 Memories with Temperature & Emissivity
Battery Life
Typ.180, min 140 hours continuous use (Alkaline, without Laser and Back Light.)
Dimensions
60.6 x 207.5 x 233.8mm(2.38×8.19.20 inch)
Weight
475 grams(16.75 oz) including batteries (AA*2pcs)
Note: Under an electromagnetic field of
3V/m from 90 to 360 MHz the
maximum error is +/-10°C
EMC/RFI: Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per
meter, but the performance of the instrument will not be permanently affected.