Mr Steam AromaSteam Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Mr Steam AromaSteam (8 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 5 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/8
MS AromaFlo®A
Table of Contents
Box Contents
. . . . . . . . . . . . . . . .
2
Assembly and Installation
General Installation
. . . . . . . . . . . . .
3
Installation of Hoses
. . . . . . . . . . . . .
4
Assembly Diagram . . . . . . . . . . . . . . . . . . 5
Electrical Wiring
. . . . . . . . . . . . . . .
6
Sta
rt-up
Initial Priming of AromaSteam System
. . .
7
Filling the Pressure Hose
. . . . . . . . . .
7
Adjusting amount of oil delivery
. . . . 7
Troubleshooting
. . . . . . . . . . . . . .
8
Technical Information
. . . . . . . . . .
8
NOTE:
It is strongly recommended that this warning sign (supplied)
be posted in a conspicuous location near the steam room.
Do not use with water soluble
fragrance or fragrance containing emulsifiers or aldehy-
des. AromaSteam system damage may result. Mr.Steam
oils are approved for operation with this system.
The use of any oils other than
Mr.Steam oils may introduce excessive concentration of
oil into the steam room, resulting in a health hazard.
Vapors may cause drowsiness and
dizziness. Keep out of the reach of children. In case of
contact with eyes, rinse immediately with plenty of
water and seek medical advice. If swallowed, rinse mouth
with water (only if the person is conscious), seek medical
advice immediately and show this container or label.
Highly Flammable. Keep away
from sources of ignition– No smoking. Keep container
tightly closed & in a well-ventilated place. This material
& its container must be disposed of as hazardous waste.
Not for use in acrylic or fiberglass
rooms.
Material Safety Data Sheet (MSDS) available upon request
WARNING
!
WARNING
!
WARNING
!
WARNING
!
signals a situation where minor injury or product
damage may occur if you do not follow instructions.
IMPORTANT NOTE:
This highlights information that is especially
relevant to a problem-free installation.
IMPORTANT NOTE:
As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient
installation and operation of this AromaSteam. These are two types of potential hazards that may occur during this installation and operation:
states a hazard which may cause serious injury
or death if precautions are not followed.
AromaSteam
(for illustrative purposes only)
This room is equipped with an aromatic oil dispensing system.
Leave the room immediately if you have any adverse or
allergic reactions, including difficulty breathing or eye, nasal,
throat, or skin irritation and seek medical attention.
mr steam.®
43-20 34th Street , Long Island City NY 11101
1 800 76 STEAM www.mrsteam.com
PUR 100405
WARNING
!
Motor Operated
Pumps 24VW
mr.steam®aromasteam
Operation and Installation Instructions
_________________________________________________
WARNING
!
CAUTION
!
mr.steam®
Sussman-Automatic Corp®
info@mrsteam.com
www.mrsteam.com
43-20 34th Street
Long Island City, NY 11101
TEL: 1 800 76 STEAM
FAX: 718 472 3256
9410 S. La Cienega Blvd.
Inglewood CA 90301
TEL: 1 800 72 STEAM
FAX: 310 216 2944
WARNING
!
PUR 100402 06/09
mr.steam
®
aromasteam Operation and Installation Instructions
______________________________________________________________________________________________
Box Contents
2
Shipping Hose
TABLE OF CONTENTS
Box Cont ents .................2
Assembly and Inst allatio n
General
..... .......... ......3
Pump Assembly
. . . . . . . . . . . . . . . . . 4
I nst allation of Hoses
...............4
Syst em Schematic
......... ... ... .5
Electrical Wiring
......... ... ... ..6
Assembly Diagram
................7
Start-up
Initial Priming of Met ering Pump
.......8
Filling the Pressure Hose
............8
Programming Table
. . . . . . . . . . . . . . . 9
Maint enance
Maintenance of Metering Pump,
Suct ion Valve, and Pressure Valve
. . . . . . . 10
Troubleshooting.... ...........11
Technical Inf ormat ion ..........11
Spare Part s .. ............. ...11
Warrant y............ ..... ...12
A Division of Suss man-Aut oma tic Corpora tion
43-20 34th S treet, Long Is land City, NY 11101 • (718) 937-4500 • 1-800-767-8326 • Fax: (718) 472-3256 • www.mrsteam.com
Wes tern Reg iona l Of fices
9410 S. La Cienega Blvd., Inglewood CA 90301 • 1-800 72 STEAM (1-800 727-8326) • Fax:(310) 216-2944
PUR 100402 - 01/06
NOTE:
Suss man-Automatic strongly recommends that this warning sign
(supplied) be posted in a conspicuous location near the steam room.
Do not us e with water soluble fragrance or fragrance containing
emulsifiers or aldehydes. AromaStean pump damage may result.
MrS team oils are approved for operation with this pump.
The us e of any oils other than MrSteam oils may introduce excessive
concentration of oil into the steam room, resulting in a health hazard.
WARNING
!
WARNING
!
signals a situation where minor injur y or product
dam-age may occur if you do not follow instructions.
IMPORTANT NOTE:
THIS HIGHLIGHTS INFORMATION THAT IS ES PECIALLY
RELEVANT TO A PROBLEM-FREE INSTALLATION.
IMPORTANT NOTE:
As you follow these ins tructions, you will notice warning and caution symbols. This blocked information is im portant for the safe and efficient installation and operation of
this AromaSteam. These are two types of potential haz ards that may occur during this ins tallation and operation:
states a haz ard which may cause serious injury
or death if precautions are not followed.
Frag rance Me tering Pump
f or Re side ntia l St eam Rooms
This ro om is equ ipped with an aromat ic o il dispe nsing syst em.
Leave th e ro om immediate ly if you have any a dverse or
allerg ic r eac tio ns, including difficult y breathing o r eye, nas al,
t hroat, o r skin irrit at ion and seek med ical a tt ention.
MrSteam
®
Commercial Steam Generators
Sussman-Automatic Corp. 43-20 34th Street , L ong Island City NY 11101
1 800 76 STEAM • www.mrs team.com
W ARN ING
!
Listed Oil Deli very
Pu mp 24V W
mr.steamaromasteam®
operation and installation instructions
_________________________________________________
WARNING
!
CAUTIO N
!
AromaSteam System 6 ft. Pressure Hose 2 ft. Suction Hose with Filter
& Bracket Assembly
(with integrated 6 ft. power cord,
8 ft. request cable and 3 ft. demand cable)
1/2 inch NPT Atomizing Nozzle Injector with Injection Hose Scent Container Cap
Demand Button
(with integral 30 ft. cable)
Installation & Operation Manual
with Peel-off Warning Label
The AromaSteam system is qualified for use with Mr.Steam residential steam generators ONLY.
For use with residential steam rooms only. Not for commercial use.
1.
Locate the AromaSteam system to monitor the consumption of essential oils and for easy oil replacement.
2.
Mr.Steam strongly suggests that the warning sticker provided be placed in a conspicuous location near the
steam room.
3.
Mr.Steam AromaSteam System is designed and intended for indoor use only and is to be located indoors in a dry
clean location and not subject to moisture, condensation or similar high humidity environments.
4.
Do not install AromaSteam Systems outdoors.
5.
Do not install AromaSteam Systems in a location where water could freeze.
6.
Do not install AromaSteam Systems near flammable or corrosive materials and chemi-
cals. Installation in areas having high concentrations of chlorine (such as pool equip-
ment room) should be avoided.
7.
Attach the AromaSteam System onto a secure vertical surface.
8.
Provide access to AromaSteam System for servicing, and refills.
9.
The system should not be installed in areas accessible to children.
A LOCKED ROOM IS STRONGLY RECOMMENDED (ie: utility room)
10.
Height difference between AromaSteam System discharge and
90 degree
Tis to be held to a maximum
6 ft. (see page 5).
Clearance to heat sources
•
Do not install the AromaSteam system directly below or above the Mr. Steam steam gen-
erator where it is subject to heat.
•
Minimum distance between the AromaSteam system and a heat source (e.g. steam gener-
ator, heating system) is ft. If this minimum distance of ft cannot be main-1.5 1.5
tained, install a radiation plate or heat insulation between the heat source and
AromaSteam system.
•
Ambient temperature at and around the AromaSteam system should not exceed 90Ëš F.
Installing the 90 degree T and Atomizing Nozzle
1.
For optimal results locate a brass 90 degree
T
(not provided) and atomizing nozzle in
the steam supply line within 10 feet of the steam head. If using copper tubing for steam
lines, install a female 1/2 NPT thread to sweat fitting in the downward facing
T.
2. T
must face downward as shown (in figure 2).
3.
Screw the atomizing nozzle into 90°
T
fitting using teflon tape on the threads.
IMPORTANT NOTE:
Follow the installation instructions for the steam
pipeline in the Mr.Steam Residential Steam Bath Installation and Operating Manual
(PUR 101289). Visit www.mrsteam.com to download this document.
mr.steam
®
aromasteam Operation and Installation Instructions
______________________________________________________________________________________________
General Installation
Steam Line
90Ëš T
Figure 2
1/2 NPT
CAUTION
!
This room is equipped with an aromatic oil dispensing system.
Leave the room immediately if you have any adverse or
allergic reactions, including difficulty breathing or eye, nasal,
throat, or skin irritation and seek medical attention.
mr steam.®
43-20 34th Street , Long Island City NY 11101
1 800 76 STEAM www.mrsteam.com
PUR 100405
WARNING
!
3


Produktspezifikationen

Marke: Mr Steam
Kategorie: Nicht kategorisiert
Modell: AromaSteam

Brauchst du Hilfe?

Wenn Sie Hilfe mit Mr Steam AromaSteam benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Mr Steam

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-