ioLogik MXIO DLL API Reference
Second Edition, June 2008
www.moxa.com/product
© 2008 Moxa Inc., all rights reserved.
Reproduction without permission is prohibited.
ioLogik MXIO DLL API Reference
The software described in this manual is furnished under a license agreement, and may be used only in
accordance with the terms of that agreement.
Copyright Notice
Copyright © 2008 Moxa Inc.
All rights reserved.
Reproduction without permission is prohibited.
Trademarks
Moxa is a registered trademark of Moxa Inc.
All other trademarks or registered marks in this manual belong to their respective manufacturers.
Disclaimer
Information in this document is subject to change without notice, and does not represent a commitment on the
part of Moxa.
Moxa provides this document “as is,” without warranty of any kind, either expressed or implied, including, but
not limited to, its particular purpose. Moxa reserves the right to make improvements, and/or changes to this
manual, or to the products, and/or the programs described in this manual, at any time.
Information provided in this manual is intended to be accurate, and reliable. However, Moxa assumes no
responsibility for its use, or for any infringements on the rights of third parties that may result from its use.
This manual might include unintentional technical or typographical errors. Changes are made periodically to the
information herein to correct such errors, and these changes are incorporated into new editions of the manual.
Technical Support Contact Information
www.moxa.com/support
Moxa Americas:
Toll-free: 1-888-669-2872
Tel: +1-714-528-6777
Fax: +1-714-528-6778
Moxa China (Shanghai office):
Toll-free: 800-820-5036
Tel: +86-21-5258-9955
Fax: +86-10-6872-3958
Moxa Europe:
Tel: +49-89-3 70 03 99-0
Fax: +49-89-3 70 03 99-99
Moxa Asia-Pacific:
Tel: +886-2-8919-1230
Fax: +886-2-8919-1231
Table of Contents
Chapter 1. Overview ....................................................................................................1-1
What is the MXIO Linux Library? ....................................................................................... 1-2
Supported Platforms ............................................................................................................. 1-2
Supported I/O Modules ........................................................................................................ 1-2
Moxa Library Comparison ................................................................................................... 1-2
Chapter 2. Programming Flow....................................................................................2-1
Connecting to a Single Ethernet I/O..................................................................................... 2-2
Connecting to Multiple Ethernet I/O .................................................................................... 2-3
Connecting to a Single Serial I/O......................................................................................... 2-4
Connecting to Multiple RS-485 I/O ..................................................................................... 2-5
Connecting to the ioLogik E2000 and Attached RS-485 I/O................................................ 2-6
Modbus Command Sets vs. Direct I/O Command Sets........................................................ 2-7
Modbus Command Sets................................................................................................ 2-7
Direct I/O Command Sets............................................................................................. 2-7
Chapter 3. MXIO API Overview ...................................................................................3-1
System Command Sets......................................................................................................... 3-2
RS-485/RS-232 I/O Connect Commands ..................................................................... 3-2
Ethernet I/O Connect Commands................................................................................. 3-2
General Commands ...................................................................................................... 3-2
Special Commands for ioLogik E2000, R2000 ............................................................ 3-2
Special Commands for ioLogik 4000 ........................................................................... 3-2
Modbus Command Sets........................................................................................................ 3-3
Direct I/O Command Sets..................................................................................................... 3-3
Digital Input Commands............................................................................................... 3-3
Digital Input Commands for ioLogik E2000, R2000 ................................................... 3-3
Digital Input / Output Mode Commands for ioLogik E2000........................................ 3-3
Counter Commands for ioLogik E2000, R2000 ........................................................... 3-4
Digital Output Commands............................................................................................ 3-4
Digital Output Commands for ioLogik E2000, R2000................................................. 3-5
Digital Output Commands for ioLogik 4000................................................................ 3-5
Pulse Output Commands for ioLogik E2000, R2000 ................................................... 3-5
Analog Input Commands.............................................................................................. 3-6
Analog Input Commands for ioLogik E2000, R2000................................................... 3-6
Analog Output Commands ........................................................................................... 3-6
Analog Output Commands for ioLogik E2000, R2000 ................................................ 3-7
Analog Output Commands for ioLogik 4000 ............................................................... 3-7
RTD Commands ........................................................................................................... 3-7
Thermocouple Commands............................................................................................ 3-8
Click&Go Logic Commands................................................................................................ 3-8
Active I/O Message Commands ........................................................................................... 3-8
Chapter 4. System Command Sets ............................................................................4-1
RS-232/RS-485 I/O Connect Commands ............................................................................. 4-2
Ethernet I/O Connect Commands......................................................................................... 4-4
General Commands .............................................................................................................. 4-5
Special Commands for ioLogik E2000, R2000 .................................................................... 4-7
Special Commands for ioLogik 4000 ................................................................................... 4-7


Produktspezifikationen

Marke: Moxa
Kategorie: Nicht kategorisiert
Modell: M-3414
Zweck: Feldstrom
Anzahl Kanäle: 4 Kanäle
Energieverbrauch: 150 mA
Genauigkeit: ±0.1%, FSR @ 25°C \n±0.3%, FSR @ 0°C, 60°C
Spannung: 0 - 5 V
Auflösung: 12 Bit
Synchronisations-Eingangsimpedanz: 500000 Ohm
Verbindungstyp: RTB
Signalentdeckung: Eingang
Modultyp: Analog
Konversionszeit: 4 ms