SPECIFICATION
MODEL APV-12-5 APV-12-12 APV-12-15 APV-12-24
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS Note.8
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
5V 12V 15V 24V
2A 1A 0.8A 0.5A
0 ~ 2A 0 ~ 1A 0 ~ 0.8A 0 ~ 0.5A
10W 12W 12W 12W
100mVp-p 120mVp-p 120mVp-p 150mVp-p
±5.0%
±1.0%
±2.0%
1500ms, 30ms / 230VAC 1500ms,30ms / 115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
76% 82% 82% 84%
5.75 ~ 6.75V 13.8 ~ 16V 17.5 ~ 21V 27.6 ~ 32.4V
0.2A/230VAC 0.35A/115VAC
COLD START 70A(twidth=120 s measured at 50% Ipeak) at 230VACμ
0.25mA / 240VAC
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
± ℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8. The model certified for CCC(GB19510.14, GB19510.1, GB17743 and GB17625.1) is an optional model . Please contact MEAN WELL for details.
Protection type : Shut off o/p voltage, clamping by zener diode
12W Single Output Switching Power Supply
Constant voltage design
Universal AC input / Full range
Protections: Short circuit / Over load / Over voltage
Fully isolated plastic case
Cooling by free air convection
Small and compact size
Class power unit, no FG
Class 2 power unit
ass LPSP
IP42 design
Suitable for LED related fixture or appliance
(such as LED Decoration or Advertisement devices)
100% full load burn-in test
Low cost, high reliability
2 years warranty
Features :
APV-1 2 s e r i e s
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
20ms/230VAC 15ms/115VAC at full load
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
File Name:APV-12-SPEC 2017-11-03
EMC IMMUNITY
Compliance to EN55032,EN61000-3-2 Class A,EN61000-3-3
Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A
EMC EMISSION
77*40*29(L*W*H)
1145.7K hrs min. MIL-HDBK-217F (25 )
0.08Kg; 120pcs/11.8Kg/1.06CUFT
110 SELV
F
UL8750,CSA C22.2 No.250.0-08, ENEC 42 design refer to EN60950 1EN61347-1,EN61347-2-13,EN62384 Independent,IP Approved; -
MAX. No. of PSUs on 16A
CIRCUIT BREAKER 17 units (circuit breaker of type B) / 29 units (circuit breaker of type C) at 230VAC
LPS
IP42
(optional)
IS 15885(Part 2/Sec13)
R-41027766
THOMAS SAMUEL THOMAS SAMUEL
(except for 15V)
File Name:APV-12-SPEC 2017-11-03
Mechanical Specification Unit:mm
Derating Curve Static Characteristics
AMBIENT TEMPERATURE ( )
LOAD (%)
-30 0 10 20 30 40 50 70
20
40
60
80
100
(HORIZONTAL)
Block Diagram
DETECTION
PWM
CIRCUIT
EMI FILTER
POWER
SWITCH-
FILTER
&
RECTIFIERS +V
-V
I/P
ING
CONTROL
50
12W Single Output Switching Power Supply APV- 1 2 s e r i e s
INPUT VOLTAGE (VAC) 60Hz
90 100 200 220210 230 250240 264
LOAD (%)
90
100
80
70
60
50
40
fosc : 67KHz
RECTIFIERS
60
45
5V
other
77
40
82.5
90
150 10±
150 10±
15.5
29
UL1569 20AWG
UL1569 18AWG
+V(Red)
-V(Black)
AC/N(Blue)
AC/L(Brown)
19
31
T case
T case: Max. Case Temperature


Produktspezifikationen

Marke: Monacor
Kategorie: Schalter
Modell: PSL-12/12

Brauchst du Hilfe?

Wenn Sie Hilfe mit Monacor PSL-12/12 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Schalter Monacor

Bedienungsanleitung Schalter

Neueste Bedienungsanleitung für -Kategorien-