Maxwell MX-25521 Bedienungsanleitung

Maxwell Multimeter MX-25521

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Maxwell MX-25521 (36 Seiten) in der Kategorie Multimeter. Dieser Bedienungsanleitung war für 5 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/36
BLUETOOTH MULTIMETER
BLUETOOTH MULTIMETER
BLUETOOTH MULTIMÉTER
BLUETOOTH MULTIMETR
BLUETOOTH MULTIMETER
MULTIMETR CYFROWY BLUETOOTH
MULTIMETRU BLUETOOTH
25521
i
U Mser anUal
GebraUchsanweisUnG
használati Utasítás
návod k poUžití
návod na poUžitie
i nstrUkcja obsłUGi
M anUal de Utilizare
DC and AC voltage measurement
Connect the black connector to
“COM”, the red connector to the
“VΩHz” socket. Set the function
selector switch to the position. “V”
Normally, the automatic metering
range switch is active, which is
indicated by on the display. AUTO”
Press the RANGE“ button to manually
set the measurement range and the
“SELECT“ DC button to select the
and AC modes. Connect the testers in
parallel with the power source for the
measurement time.
DC and AC current measurement
Connect the black wire to COM” and
the red wire to the or mA “10A
socket, max. 600 mA or for max 10A
measurements. Set the function switch
to the appropriate measuring range,
uA, mA or 10A. Normally, the automatic
metering range switch is active, which
is indicated by on the display. AUTO”
Press the button to manually “RANGE“
set the measurement range and the
“SELECT“ button to select the DC
and AC modes. Connect the testers in
series to the circuit to be measured.
Frequency and fill factor
measurement
Connect the black connector to
“COM”, the red connector to the
“VΩHz” socket. Frequency and ll
factor measurement available for the
following functions: “V”, “uA, “mA,
“10A, rotate the function selector
switch. Press the button to “SELECT“
set the alternating waveform rst, then
use the button to select the “HZ/%“
measurement. Connect the testers in
parallel with the power source for the
measurement time.
Non-contact frequency measure-
ment
Connect the red connector to the
“VΩHz” socket. Turn the function
selector switch to the NCF mode
and then approach the front of
the instrument (NCV/NCF) to 1-2
centimeters to the wire to be
measured. The measured value can be
read from the display.
Non-contact AC voltage detection
Turn the function selector switch to
NCV mode and then approach the
front of the instrument (NCV/NCF)
to 1-2 centimeters to the wire to be
measured. In the case of detection,
the display of the instrument ashes
red and beeps intermittently. The more
often there is a sound and light signal
the better the result. The display shows
4 horizontal lines indicating the hit,
the higher the value being the more
secure.
Resistance, tear and diode, capacity
measurement
Connect the black connector
to “COM”, the red connector
EN USER MANUAL
to the “VΩHz” socket. Turn
the function selector switch to
. Use the button “SELECT“
to set the measurement type. For
diode measurement, the instrument
shows the opening voltage of the
diode or in the closing direction. OL
In case of a break test, the instrument
outputs a beeping sound if the
measured value is less than 50 ohms.
For resistance measurements, wait
for a few seconds for measurements
of mega ohm while the measured
value is stabilized on the display. By
pressing the button you can “RANGE“
manually select the measuring range,
press and hold to return to automatic
mode. Before capacitor measurement,
discharge the capacitors in any case,
otherwise the voltage stored inside
them can damage the instrument. For
larger capacities, the measurement
may take several seconds.
Display maximum and minimum
values
After nishing measurements, you
have the option of calling the largest,
smallest, and dierent values. Press
the “MAX/MIN“ button to display the
desired value. MAX - maximum, MIN -
minimum, MAX-MIN - dierence value
Relative measurement method
During measurement, press the
“REL button to activate the relative
measurement, the instrument from
there uses the previous measurement
as a starting point.
Data hold
During measurement, press the
“HOLD“ button so that the measured
value remains on the display even after
removing the measuring testers. Press
again to reset the measurement.
Backlight
To turn on the backlight, press the
“HOLD“ button for a long time. It will
switch o approx. after 15 seconds, it is
automatically turns o.
Automatic switch off
The instrument automatically switches
o for approx. after 5 minutes. Press
“SELECT“ repeatedly to switch on.
Smart mode, wireless Bluetooth
connection
The instrument is suitable for storing
and displaying measurements on an
external device. In any mode of the
instrument, press and hold the TX
button for a long time. The Tx display
on the display indicates the activation
of the wireless Bluetooth connection.
An app for Android and iOS can
be downloaded from Play Market
and AppStore: „MAXWELL
MULTIMETERS


Produktspezifikationen

Marke: Maxwell
Kategorie: Multimeter
Modell: MX-25521

Brauchst du Hilfe?

Wenn Sie Hilfe mit Maxwell MX-25521 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Multimeter Maxwell

Bedienungsanleitung Multimeter

Neueste Bedienungsanleitung für -Kategorien-