Maxwell MX-25306 Bedienungsanleitung

Maxwell Multimeter MX-25306

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Maxwell MX-25306 (30 Seiten) in der Kategorie Multimeter. Dieser Bedienungsanleitung war für 4 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/30
U Mser anUal
anwendUngsinforMation
Használati Utasítás
ManUal de Utilizare
Užívateľská prírUčka
Product code / Produkt code / Termékkód / Cod produs / Kód produkta:
25306
EN User Manual
s afety inforMation
This device was designed according to the
IEC1010 standard (safety standard by the
International Electrotechnical Commission).
Please read the following safety information
before use:
values than 1000V DC or 750V AC.
the grounding, connection and insulation
before measuring above 36V DC or 25V AC to
avoid electric shock.
selecting the function or measuring range.
but you need to be cautios as well for your
own safety.
current.
g eneral cHaracteristics
Display LCD
1999 (3 ½) digit, automatic
polarity display
dual integral A/D conversion
rate appr. 3 /second
value
indicated by the highest
number: „ OL
environment
(0 ~ 40) °C, relative
humidity: <80%
Dimensions 189mm x 97mm x 35mm
Weight appr. 400g
Accuracy ±( % x read data + number)
temperature
(23 ± 5) °C, relative humidity:
<75%
t ecHnical index
DCV
Range Accuracy Resolution
200mV ±(0,5%+3) 100μV
2V ±(0,5%+3) 1mV
20V ±(0,5%+3) 10mV
200V ±(0,5%+3) 100mV
1000V ±(1,0%+5) 1V
protection
250V DC or AC peak value
200mV
1000V DC or AC peak value
ACV
Range Accuracy Resolution
200mV ±(1,2%+3) 100μV
2V ±(0,8%+5) 1mV
20V ±(0,8%+5) 10mV
200V ±(0,8%+5) 100mV
750V ±(1,2%+5) 1V
protection
250V DC or AC peak value
200mV
1000V DC or AC peak value
range
40~400Hz under the 200V
range, 40~100Hz in the 750V
range
DCA
Range Accuracy Resolution
2mA ±(0,8%+3) 1μA
20mA ±(0,8%+3) 10μA
200mA ±(1,2%+4) 100μA
20A ±(2,0%+5) 10A
current
20A (for no longer than 10
seconds)
User Manual EN
protection
0.2A / 250V biztosíték a 200mA
alatti tartományokban 12A
/ 250V biztosíték 20A -es
tartományban
ACA
Range Accuracy Resolution
2mA ±(1,0%+5) 1μA
20mA ±(1,0%+5) 10μA
200mA ±(2,0%+5) 100μA
20A ±(3,0%+10) 10A
20A (for no longer than 10
seconds)
protection
0.2A / 250V fuse for under
200mA range 12A / 250V
fuse for the 20A range
range 40~200 Hz
Resistance
Range Accuracy Resolution
200 Ω ±(0,8%+5) 0.1 Ω
2k Ω ±(0,8%+3) 1 Ω
20k Ω ±(0,8%+3) 10 Ω
200k Ω ±(0,8%+3) 100 Ω
2M Ω ±(0,8%+3) 1k Ω
20M Ω ±(1,0%+15) 10k Ω
200M Ω
±[1,0%
(reading-10)
+20]
1M Ω
value
Note:
Capacity
Range Accuracy Resolution
20nF ±(2,5%+20) 10pF
200nF ±(2,5%+20) 100pF
2μF ±(2,5%+20) 1nF
20μF ±(2,5%+20) 10nF
200μF ±(5,0%+5) 100nF
3kV DC or AC peak
value
Range Accuracy Resolution
2mH ±(2,5%+20) 1uH
20mH ±(2,5%+20) 10uH
200mH ±(2,5%+20) 100uH
2H ±(2,5%+20) 1mH
20H ±(2,5%+20) 10mH
3kV DC or AC peak
value
Range Accuracy Resolution
(-40 ~
1000) °C
±(1,0%+4)
<400 °C
±(1,5%+15)
>=400 °C
1 °C


Produktspezifikationen