Makita RP1800 Bedienungsanleitung

Makita Fräse RP1800

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Makita RP1800 (16 Seiten) in der Kategorie Fräse. Dieser Bedienungsanleitung war für 24 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/16
1
ENGLISH (Original instructions)
INSTRUCTION MANUAL
DOUBLE INSULATION
WARNING:
For your personal safety, READ and UNDERSTAND before using.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Router
RP1800
RP1800F
RP1801
RP1801F
RP2300FC
RP2301FC
009852
2
ENGLISH
SPECIFICATIONS
Model RP1800 /
RP1800F
RP1801 /
RP1801F RP2300FC RP2301FC
Collet chuck capacity 12 mm or 1/2"
Plunge capacity 0 - 70 mm
No load speed (min
-1) 22,000 9,000 - 22,000
Overall length 312 mm
Net weight 6.0 kg 6.1 kg
Safety class /II
• Due to our continuing programme of research and development, the specifications herein are subject to change without notice.
• Note: Specifications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
END201-4
Symbols
The following show the symbols used for the equipment.
Be sure that you understand their meaning before use.
ï½¥ Read instruction manual.
ï½¥ DOUBLE INSULATION
ï½¥ Only for EU countries
Do not dispose of electric equipment
together with household waste material!
In observance of European Directive
2002/96/EC on waste electric and
electronic equipment and its
implementation in accordance with
national law, electric equipment that
have reached the end of their life must
be collected separately and returned to
an environmentally compatible
recycling facility.
ENE010-1
Intended use
The tool is intended for flush trimming and profiling of
wood, plastic and similar materials.
ENF002-1
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated in accordance with European
Standard and can, therefore, also be used from sockets
without earth wire.
For Model RP1800
ENF100-1
For public low-voltage distribution systems of
between 220 V and 250 V.
Switching operations of electric apparatus cause voltage
fluctuations. The operation of this device under
unfavorable mains conditions can have adverse effects
to the operation of other equipment. With a mains
impedance equal or less than 0.40 Ohms it can be
presumed that there will be no negative effects. The
mains socket used for this device must be protected with
a fuse or protective circuit breaker having slow tripping
characteristics.
For Model RP1800F
ENF100-1
For public low-voltage distribution systems of
between 220 V and 250 V.
Switching operations of electric apparatus cause voltage
fluctuations. The operation of this device under
unfavorable mains conditions can have adverse effects
to the operation of other equipment. With a mains
impedance equal or less than 0.39 Ohms it can be
presumed that there will be no negative effects. The
mains socket used for this device must be protected with
a fuse or protective circuit breaker having slow tripping
characteristics.
For Model RP1801
ENF100-1
For public low-voltage distribution systems of
between 220 V and 250 V.
Switching operations of electric apparatus cause voltage
fluctuations. The operation of this device under
unfavorable mains conditions can have adverse effects
to the operation of other equipment. With a mains
impedance equal or less than 0.38 Ohms it can be
presumed that there will be no negative effects. The
mains socket used for this device must be protected with
a fuse or protective circuit breaker having slow tripping
characteristics.
3
For Model RP1800,RP1800F,RP1801
ENG102-3
Noise
The typical A-weighted noise level determined according
to EN60745:
Sound pressure level (L
pA) : 86 dB(A)
Sound power level (LWA) : 97 dB(A)
Uncertainty (K) : 3 dB(A)
Wear ear protection
ENG223-2
Vibration
The vibration total value (tri-axial vector sum)
determined according to EN60745:
Work mode : cuttig grooves in MDF
Vibration emission (ah) : 4.0 m/s2
Uncertainty (K) : 1.5 m/s2
For Model RP2300FC,RP2301FC
ENG102-3
Noise
The typical A-weighted noise level determined according
to EN60745:
Sound pressure level (L
pA) : 87 dB(A)
Sound power level (LWA) : 98 dB(A)
Uncertainty (K) : 3 dB(A)
Wear ear protection
ENG223-2
Vibration
The vibration total value (tri-axial vector sum)
determined according to EN60745:
Work mode : cuttig grooves in MDF
Vibration emission (ah) : 4.5 m/s2
Uncertainty (K) : 1.5 m/s2
ENH101-13
For European countries only
EC Declaration of Conformity
We Makita Corporation as the responsible
manufacturer declare that the following Makita
machine(s):
Designation of Machine:
Route
r
Model No./ Type:
RP1800,RP1800F,RP1801,RP2300FC,RP2301FC
are of series production and
Conforms to the following European Directives:
98/37/EC until 28th December 2009 and then with
2006/42/EC from 29th December 2009
And are manufactured in accordance with the following
standards or standardised documents:
EN60745
The technical documentation is kept by our authorised
representative in Europe who is:
Makita International Europe Ltd,
Michigan, Drive, Tongwell,
Milton Keynes, MK15 8JD, England
30th January 2009
000230
Tomoyasu Kato
Director
Makita Corporation
3-11-8, Sumiyoshi-cho,
Anjo, Aichi, JAPAN
GEA005-3
General Power Tool Safety
Warnings
WARNING Read all safety warnings and all
instructions. Failure to follow the warnings and
instructions may result in electric shock, fire and/or
serious injury.
Save all warnings and
instructions for future reference.
The term "power tool" in the warnings refers to your
mains-operated (corded) power tool or battery-operated
(cordless) power tool.
Work area safety
1. Keep work area clean and well lit. Cluttered or
dark areas invite accidents.
2. Do not operate power tools in explosive
atmospheres, such as in the presence of
flammable liquids, gases or dust. Power tools
create sparks which may ignite the dust or fumes.
3. Keep children and bystanders away while
operating a power tool. Distractions can cause
you to lose control.
Electrical safety
4. Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power
tools. Unmodified plugs and matching outlets will
reduce risk of electric shock.
5. Avoid body contact with earthed or grounded
surfaces such as pipes, radiators, ranges and
refrigerators. There is an increased risk of
electric shock if your body is earthed or grounded.
6. Do not expose power tools to rain or wet
conditions. Water entering a power tool will
increase the risk of electric shock.
7. Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges or
moving parts. Damaged or entangled cords
increase the risk of electric shock.

Produktspezifikationen

Marke: Makita
Kategorie: Fräse
Modell: RP1800

Brauchst du Hilfe?

Wenn Sie Hilfe mit Makita RP1800 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Fräse Makita

Bedienungsanleitung Fräse

Neueste Bedienungsanleitung für -Kategorien-