Seite 1/2
Straussā„¢ Volume Control
200 Watts (100 RMS)
Cat. No. SGVSM
DI-000-SGVSM-00A
INSTALLATION
WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND
REGULATIONS.
WARNING: MAXIMUM AMPLIFIER POWER IS 100 WATTS PER CHANNEL. HIGHER AMPLIFIER POWER MAY
CAUSE DAMAGE.
Before starting connections, please note that the left and right attenuator circuits are completely isolated from each other
to prevent instability when used with certain types of ampliļ¬ers which have ļ¬‚oating grounds. If the ampliļ¬er to be used
has common grounds between channels, a 3 wire system can be used between the ampliļ¬er and control, but it will be
necessary to connect a jumper between the control ground returns (L- & R-).
If one ground is open, there will be no output on the ungrounded channel at any attenuator setting.
The connectors on the attenuator are the screw-to-tighten type. Connect wires per WIRING DIAGRAM as follows:
1. Select location for mounting control.
NOTE: Due to the depth of volume control, a low-voltage ring or deep electrical box is recommended.
2. Make connections by stripping wire insulation back about 1/4ā€ (.63 cm). Twist any loose strands tightly.
NOTE: It is recommended that at least 16 AWG speaker wire be used for runs up to 30ā€™ (9.1 m). For runs longer than
30ā€™ (9.1 m), use 14-18 AWG wire.
3. Insert the wires from the ampliļ¬er into the ā€œTO AMPā€ openings of the connector, Positive-to-Positive and Negative-to-
Negative, then tighten screws. Check for stray wire strands that might cause a short circuit. Make sure the metal part of
the screw connector engages the bare wire, NOT the insulation!
4. Similarly, connect speaker wires to the ā€œTO SPEAKERā€ openings and tighten screws.
IMPEDANCE NOTE: There are two impedance settings. 2x is used for up to four rooms connected to a single 8 ohm
rated ampliļ¬er output and 6x which is used for 5 to six rooms.
5. ensuring that terminal connector is at top. Install control in its operating location,
NOTE: Leave control 3 or 4 positions above minimum volume before starting the system for the ļ¬rst time to avoid
damaging the speakers, while still being loud enough to observe operation.
INSTALLATION MANUAL
DI-000-SGVSM-00A
SPECIFICATIONS
Attenuator Type: Ceramic Resistive Network
Switch: 12 position slider, make-before-break contacts, low torque speciļ¬cations for smooth feel
Connector: Screw-tight type, removable connector block
Ampliļ¬er Power Rating: 200 Watts (100 RMS)
Impedance Matching: 2 x 8 Ohms
(provided by jumpers) 6 x 47 Ohms
Frequency Response: 20-20kHz +/- 1db, 4-16 Ohm load
Attenuation: 36db
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
www.leviton.com/lin
DI-000-SGVSM-00A
4 CONDUCTOR SPEAKER WIRE
1 x 6
Passive Audio Module
4 CONDUCTOR
SPEAKER WIRE
4 CONDUCTOR SPEAKER WIRE
ZONE 1 ZONE 2 ZONE 3
AMPLIFIER
SPEAKER RIGHTSPEAKER RIGHT SPEAKER LEFTSPEAKER LEFTSPEAKER LEFT SPEAKER RIGHT
WIRING DIAGRAM 1: MULTIPLE VOLUME CONTROLS
Plug/Connector Wiring
R L R L
SPEAKER AMP
2X
R
L
2x is used for up to four rooms
connected to a single 8 ohm
rated amplifier output, 6x is
used for 5 to six rooms
6X
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the beneļ¬t of anyone else that this product at the time of its sale by Leviton is free of defects in materials
and workmanship under normal and proper use for two years from the purchase date. Levitonā€™s only obligation is to correct such defects by repair or replacement, at
its option, if within such two year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co.,
Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability
for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or
implied warranties of any kind, including merchantability and ļ¬tness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction,
the duration of any such implied warranty, including merchantability and ļ¬tness for a particular purpose, is limited to two years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or proļ¬ts or delay or failure
to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.


Produktspezifikationen

Marke: Leviton
Kategorie: Regler
Modell: SGVSM-W

Brauchst du Hilfe?

Wenn Sie Hilfe mit Leviton SGVSM-W benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Regler Leviton

Bedienungsanleitung Regler

Neueste Bedienungsanleitung fĆ¼r -Kategorien-