Digital Multimete
1000V
10A
40M
Ω
• DATA & RANGE HOLD
• AUDIBLE CONTINUITY
• MIN / MAX / RELATIVE
• TEMPERATURE
• DIODE TEST
• CAPACITANCE &
FREQUENCY
2
GENERAL SPECIFICATIONS
Klein Tools MM600 is an automatically ranging digital multimeter that
measures AC/DC voltage, AC/DC current, and resistance. It can also
measure temperature, capacitance, frequency, duty-cycle, test diodes
and continuity.
• Operating Altitude: 6562 ft. (2000m)
• Relative Humidity: <90% non-condensing
• Operating Temp: ° ° ° °14 F to 122 F (-10 C to 50 C)
• Storage Temp: ° ° ° °-4 F to 140 F (-30 C to 60 C)
• Accuracy: Values stated at 65°F to 83°F (18°C to 28°C)
• Temp Coef cient: °0.1 x (Quoted Accuracy) per C above
28 C or below 18 C, corrections are required when ambient ° °
working temp is outside of Accuracy Temp range
• Dimensions: 7.02" x 3.54" x 2.10" (178.3 x 89.9 x 53.3 mm)
• Weight: 14.6 oz. (414 g)
• Calibration: Accurate for one year
• Standards: Conforms to: UL STD 61010-1, 61010-2-030,
61010-2-033.
Certified to: CSA STD C22.2 # 61010-1,
61010-2-030, 61010-2-033.
IEC EN 61010-1, 61010-2-030,
61010-2-033, 61326-1.
• Pollution degree: 2
• Accuracy: ± (% of reading + # of least significant digits)
• Drop Protection: 6.6 ft. (2m)
• WARNINGSIngress Protection: IP42 (except test lead jacks, see )
• Safety Rating:
CAT IV 600V, CAT III 1000V, Class 2,
Double insulation
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building’s low-voltage MAINS installation.
CAT IV: Measurement category IV is applicable to test and
measuring circuits connected at the source of the building’s
low-voltage MAINS installation.
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
3
ELECTRICAL SPECIFICATIONS
VOLTAGE (AUTO-RANGING)
Function Range Resolution Accuracy (
50–60 Hz
)
AC Voltage
(V AC)
4.000V 1mV ±(1.0% + 5 digits)
40.00V 10mV ±(1.2% + 5 digits)
400.0V 100mV ±(1.5% + 5 digits)
1000V 1V
DC Voltage
(V DC)
400.0mV 0.1mV ±(1.0% + 8 digits)
4.000V 1mV
±(1.0% + 3 digits)40.00V 10mV
400.0V 100mV
1000V 1V ±(1.2% + 3 digits)
Input Impedance: 10MΩ
Frequency Range: 50 to 400Hz
Maximum Input: 1000V AC RMS or 1000V DC
CURRENT (AUTO-RANGING)
AC Current
(μA and mA)
400.0μA 0.1μA
±(1.5% + 3 digits)
4000μA 1μA
40.00mA 10μA
400.0mA 100μA
10.00A 0.01A ±(2.0% + 5 digits)
DC Current
(μA and mA)
400.0μA 0.1μA
±(1.0% + 3 digits)
4000μA 1μA
40.00mA 10μA
400.0mA 100μA
10.00A 0.01A ±(1.5% + 3 digits)
Overload Protection: 500mA / 1000V and 10A / 1000V Fuses
Frequency Range: 50 to 400Hz
Maximum Input: µA/mA setting: 400mA AC RMS / DC
10A setting: 10A AC RMS / DC
RESISTANCE (AUTO-RANGING)
Function Resolution Accuracy
400.0Ω 0.1Ω
±(1.5% + 5 digits)
4.000kΩ 1Ω
40.00kΩ 10Ω
400.0kΩ 100Ω
4.000MΩ 1kΩ ±(2.0% + 10 digits)
40.00MΩ 10kΩ
Maximum Input: 600V DC or 600V AC RMS