Kitchen Brains Modularm 75LC Bedienungsanleitung


Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Kitchen Brains Modularm 75LC (12 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war fĂĽr 17 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/12
®
Kitchen Brains © 2016 | www.KitchenBrains.com | 229-40072 E Page 1 of 12
24/7 Toll-Free Technical Support
1-800-243-9271
(from the U.S., Canada and the Caribbean)
Save the instructions
for future reference.
www.KitchenBrains.com
INSTALLATION &
OPERATING GUIDE
MODULARM 75LC Multi-Monitor
This document contains confidential information. The dissemination, publication, copying, or duplication of this document or the software described herein without prior written authorization is strictly prohibited.
Page 2 of 12
MODULARM 75LC Multi-Monitor Installation & Operating
NOTICES
Before you start, please read these instructions
thoroughly in order to obtain maximum benefit from
the capabilities that this product offers.
Thank you for purchasing the 75LC multi-monitor. The 75LC
integrates sophisticated function with easy operation.
Patented Autoset* Technology, combined with common
pre-programmed default settings eliminates the need for
manual programming in most applications. PAS-PRO™
password programming allows for easy and secure custom
configuration. All product functions and accessories may be
used simultaneously or you may use only those required for
your application. A simple, 3 button user interface combined
with prioritized intuitive visual alarm display makes the 75LC
extremely user friendly.
OVERVIEW
75LC FUNCTIONS:
The 75LC offers the following functions: (Patented
Operation, other Patents Pending.)
1. HI & LO Temperature Alarm with Patented Autoset
Technology.
2. AC Failure Alarm with built-in rechargeable battery
and built in recharging circuitry.
3. Door Ajar Alarm. (Requires magnetic contacts. See
pg. 3)
4. Panic (Entrapment) Alarm (Requires optional IP-1
Illuminated Button See pg. 3)
5. Manual and patented timed light control.
6. HACCP monitoring. (additional equipment required)
7. Remote notification. (additional equipment required)
8. Built in audible alarm.
*What is Autoset?
Patented Autoset Technology selects the right alarm temp
setpoints for monitoring a cooler or a freezer automatically,
virtually eliminating the need for manual programming.
Common cooler and freezer setpoints are pre-loaded into
the 75LC. Autoset Setpoints are:
COOLER FREEZER
HI 42F (6C) HI 10F (-12C)
LO LO 30F (-1C) -20F (-29C)
Cooler setpoints are the default settings, used for cooler
monitoring. If the compartment is a freezer, Autoset
detects the lower compartment temperature and
automatically changes to the freezer setpoints. (Freezer
defaults won’t revert to cooler defaults if temperature rises.
Cooler defaults can be easily manually restored when
necessary.) Manually changing setpoints in the program
menu automatically disables Autoset.
THREE BUTTON USER INTERFACE:
Test (Up):
Lights (Prog):
Silence (Down):
WHILE IN RUN OR ALARM MODE
Test: Press to test and to view alarm
parameter settings.
Lights: Press to manually activate and
deactivate compartment
Silence: Press to acknowledge an
alarm.
WHILE IN PROGRAM MODE
Up: Press to increase and alarm
parameter values.
Lights: Press to select PAS-PRO™
preset and program menu options.
Down: Press to decrease alarm
parameter values.
VISUAL ALARM ANNUNCIATION:
NOTE the following:
1. During normal operation the monitored temp
displays constantly.
2. Any abnormal or alarm condition (except Panic
Alarm) alternates between monitored condition
display and monitored temp as follows: (In order
of priority.)
ALARM TYPE ABNORMAL
CONDITION
ALARM
CONDITION
PANIC ALARM [Non applicable] “HLP” + “HLP”
DOOR AJAR Door Light On “Dor” +
Temperature
TEMP OUT OF
RANGE
“HI” or “LO” +
Temperature
“HI” or “LO”
+ “AL” +
Temperature
AC POWER
FAILURE
“PF” +
Temperature
A single dot will
display
Panic Alarm Operation: Two types of Panic Alarm are
available:
• Manual Panic Alarm – (Requires optional IP-1).
The alarm can be cleared by either pressing the
Silence button on the 75LC or by opening and
closing the door. (This requires door contacts).
• Auto Panic Alarm – (Requires magnetic contacts,
and either or both of the following IP-1 & MD -1).
Auto Panic offers protection for persons who may
be hurt or disabled and cannot activate a Manual
Panic Alarm.
Kitchen Brains © 2016 | www.KitchenBrains.com | 229-40072 E
This document contains confidential information. The dissemination, publication, copying, or duplication of this document or the sof tware described herein without prior written authorization is strictly prohibited.
Page 3 of 12
MODULARM 75LC Multi-Monitor Installation & Operating
Using AutoPanic with an IP-1:
• If Autopanic is enabled, pressing the IP-1 at
any time while the door is closed starts the 20
minute Auto Panic Timer. When the Auto Panic
timer runs out, the IP-1 starts to beep and blink
for 40 seconds. Repressing IP-1 during a beep
and blink resets the Auto Panic Timer for 20
minutes.
• If not pressed, A Panic Alarm automatically (HLP)
annunciates on the 75LC to let others know that
someone may be injured or disabled inside the
walk-in. Auto Panic Alarm is cleared in the same
way as a Manual Panic Alarm.
Using AutoPanic with an MD-1:
• The MD-1 makes Autopanic easier to use. Each
time motion is detected, the MD-1 restarts the 20
minute Auto Panic Timer. If no motion is detected
for 20 minutes the IP-1 (if present) starts to beep
and blink for 40 seconds.
• If no motion is detected a Panic Alarm (HLP)
automatically annunciates on the 75LC to let
others know that someone may be injured or
disable inside the walk-in. Auto Panic Alarm is
cleared the same way as a Manual Panic Alarm.
AC Power Failure Operation:
• When power failure occurs: The 75LC will
alternate PF and the Monitored temperature
for 1 minute as shown above under “Abnormal
Condition”.
• For power failures under 1 minute: Normal
operation restores automatically and the incident
is ignored.
• For power failures beyond 1 minute: The
Alarm relay activates, and the horn will chirp
intermittently with a blinking decimal point.
Pressing at any time during a power Silence
failure silences the horn for 1 minute, and briefly
displays the monitored condition.
ACCESSORIES:
Three accessories expand 75LC operation:
1. IP-1 Illuminated Push Button
2. MD-1 Motion Detector
3. . MC-1 Magnetic Contacts
These accessories are low voltage devices, connected
directly to and powered by the 75LC. Accessories may
be used individually or in combination. To help eliminate
programming when common settings are desired, the 75LC
comes equipped with Autodetect.
What is Autodetect?
The Autodetect function in the 75LC senses if and when
an accessory is connected to the 75LC and automatically
integrates the connected accessory into device
operation. No special programming is required. The 75LC
ships with Autodetect enabled for the accessory inputs.
(Ex: If magnetic contacts are not connected, the 75LC
operates as if there are no magnetic contacts. Once
magnetic contacts are connected, Autodetect senses this
and provides door ajar alarm function and automatically
automatic lights on function when the door is open.)
Accessories Information:
• IP-1 Illuminated Push Button – low voltage The
IP-1 inside mounts of the walk-in and provides
both a lights control switch panic alarm and a
switch. (Press to control lights, press and hold
for 2 seconds to activate Panic Alarm ). “HLP”
A buzzer and lights built into the IP-1 provide
warning to personnel in the walk-in that lights
may turn off if the IP-1 isn’t pressed.
• MD-1 Motion Detector – (Not recommended
for freezers) low voltage MD-1 The mounts
inside of the walk-in and duplicates the light ON
control function of the IP-1 button when activated
by movement of personnel inside of the walk-in.
• Low voltage MC-1 Magnetic Contacts –
magnetic contacts sense door status and
provide both a door ajar alarm switch and a
lights on switch relative to the status of the
door. One set of magnetic contacts come with
each 75LC, various styles are available.
OPERATION
LIGHT CONTROL OPERATION: The 75LC offers three ways
to control lights:
1. Regular timed lighting
2. Patented timed lighting with Auto Panic (default),
3. Untimed, manual on-off light control (replaces light
switches.)
Password selectable presets are used to easily change or
select the desired mode of operation for your configuration
(See pg. 6)
NOTE: The DOOR light blinks whenever lights are on.
1. Regular Timed Lighting Operation – When lights
turn on, the lights-off timer is activated. Lights will
turn off when the lights-off timer expires. Operation
is as follows:
• Without Accessories: Press the Lights Button
on the 75LC to turn lights on and start lights-off
Kitchen Brains © 2016 | www.KitchenBrains.com | 229-40072 E
This document contains confidential information. The dissemination, publication, copying, or duplication of this document or the software described herein without prior written authorization is strictly prohibited.


Produktspezifikationen

Marke: Kitchen Brains
Kategorie: Nicht kategorisiert
Modell: Modularm 75LC

Brauchst du Hilfe?

Wenn Sie Hilfe mit Kitchen Brains Modularm 75LC benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Kitchen Brains

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung fĂĽr -Kategorien-