Water Supply Potable City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33° - 100°F (0.6° - 37.8° C)
Service Flow Rate 0.5 GPM (1.89 L/min.) @ 60 psi.
PRODUCT DATA SHEETS
System tested and certified by NSF International against NSF/
ANSI Standard 42, 53, 401 and CSA B483.1 for the reduction of
contaminants specified on the Performance Data Sheet.
This system has been tested according to NSF/ANSI Standards 42, 53, 401 and CSA B483.1 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI Standards 42, 53, 401 and CSA B483.1.
Chlorine Taste/Odor 2.0 mg/L ± 10% 50% reduction >97.5%
Particulate Class I* At least 10,000 particles/mL 85% reduction 98.4%
Lead***: @ pH 6.5 / @ pH 8.5 0.150 mg/L ± 10% 0.010 mg/L 99.3% / >99.4%
Mercury: @ pH 6.5 / @ pH 8.5 0.006 mg/L ± 10% 0.002 mg/L 96.7% / 96.7%
Asbestos 107 to 108 bers/L†† 99% >99%
Cysts†50,000/L min. 99.95% 99.99%
Turbidity 11 NTU ± 10% 0.5 NTU 98.6%
Alchor 0.040 mg/L ± 10% 0.002 mg/L 99.4%
Atrazine 0.009 mg/L ± 10% 0.003 mg/L >94.8%
Benzene 0.015 mg/L ± 10% 0.005 mg/L >96.7%
Carbofuran 0.080 mg/L ± 10% 0.040 mg/L 98.7%
Chlorobenzene 2.000 mg/L ± 10% 0.100 mg/L 99.9%
Endrin 0.006 mg/L ± 10% 0.002 mg/L 96.6%
Ethylbenzene 2.100 mg/L ± 10% 0.700 mg/L 99.9%
Lindane 0.002 mg/L ± 10% 0.0002 mg/L 99%
MTBE 0.015 mg/L ± 10% 0.005 mg/L 90.9%
O-Dichlorobenzene 1.800 mg/L ± 10% 0.600 mg/L 96.7%
Tetrachloroethylene 0.015 mg/L ± 10% 0.005 mg/L 96.7%
Toxaphene 0.015 mg/L ± 10% 0.003 mg/L 93.3%
TTHM 0.045 mg/L ± 10% 0.080 mg/L 99.9%
Styrene 2.000 mg/L ± 10% 0.100 mg/L >99.9%
VOC 0.300 mg/L ± 10% 0.015 mg/L 99.8%
Atenolol 200 ng/L ± 20% 30 ng/L >95.1%
Trimethoprim 140 ng/L ± 20% 20 ng/L >96.7%
Linuron 140 ng/L ± 20% 20 ng/L >96.2%
Estrone 140 ng/L ± 20% 20 ng/L >96.8%
Meprobamate 400 ng/L ± 20% 60 ng/L 95.3%
Carbamazepine 1400 ng/L ± 20% 200 ng/L >98.5%
DEET 1400 ng/L ± 20% 200 ng/L >98.5%
Metolachlor 1400 ng/L ± 20% 200 ng/L 98.5%
■ It is essential that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as advertised.
Property damage can occur if all instructions are not followed.
■ The disposable cartridge must be changed at least every 6 months.
■ Use replacement filter T1RFKB2, Part #46 9083. 2016 suggested retail
price of $54.99 U.S.A./$54.99 Canada. Prices are subject to change without
notice.
■ The filter monitor system measures the amount of water that passes
through the filter and alerts you when it is time to replace the filter. To learn
how to check the water filter status, see “Using the Controls” or “Water
Filtration System” in the User Instructions or User Guide.
■ After changing the water filter, flush the water system. See “Water and Ice
Dispensers” or “Water Dispenser” in the User Instructions or User Guide.
■ These contaminants are not necessarily in your water supply. While testing
was performed under standard laboratory conditions, actual performance
may vary.
■ The product is for cold water use only.
* Class I particle size: >0.5 to <1 um
*** Compliant for Lead reduction requirements under NSF/ANSI
Standard 53 as tested by Pace Analytical Services, Inc.
† Based on the use of Cryptosporidium parvum oocysts
†† Test requirement is at least 100,000 particles/mL of AC Fine Test
Dust
Âź NSF is a registered trademark of NSF International.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.89 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certified under NSF 401 have been deemed as “emerging compounds/incidental contaminants.” Emerging compounds/incidental
contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these
compounds can affect the public acceptance/perception of drinking water quality.
■ The water system must be installed in compliance with state and local laws
and regulations.
■ Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system. Systems certified
for cyst reduction may be used on disinfected waters that may contain
filterable cysts. EPA Est. No. 082047-TWN-001
■ Refer to the “Warranty” section for the Manufacturer’s limited warranty,
name and telephone number.


Produktspezifikationen

Marke: Kenmore
Kategorie: Nicht kategorisiert
Modell: 09083

Brauchst du Hilfe?

Wenn Sie Hilfe mit Kenmore 09083 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Kenmore

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung fĂŒr -Kategorien-