JUNG 247EB Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für JUNG 247EB (4 Seiten) in der Kategorie Empfänger. Dieser Bedienungsanleitung war für 18 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
TRONIC amplifier, built-in
Light Management
TRONIC amplifier, built-in
Art.-No.: 247 EB
Operationsmanual
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and
other hazards.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
The load is not electrically isolated from the mains even when the device is switched off.
Do not connect any electronic lamps, e.g. switchable or dimmable compact fluorescent
lamps or LED lamps. Device can be damaged.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
picture 1
(1) Power extension
(2) Load connection
(3) Dimmer connection
3 Function
Intended use
- Output extension of TRONIC dimmers, which work according to the phase section
principle.
- Output extension of universal dimmers, which have detected an ohmic or capacitive basic
load.
Do not operate universal dimmers with an inductive load.
- Connection of filament lamps, HV halogen lamps and TRONIC transformers with halogen
lamps.
- Suitable for mixed operation up to the specified output (see chapter 5.1. Technical data)
- Do not operate the corresponding dimmers without a load.
- Installation in false ceilings or surface mounting
1/4
82539913
J:0082539913 11.08.2010
Product characteristics
- Connection of multiple power extensions to one dimmer possible
- Operation using upstream dimmer
- Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest
- Electronic over-temperature protection
i Brightness differences between the lighting at the dimmer and the lightning at the power
extension are possible.
4 Information for electrically skilled persons
4.1 Fitting and electrical connection
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.
Fitting and connecting the power extension
i Use the same external conductor for dimmers and power extensions. Do not swap L and N
on the power extension. Otherwise, there is the risk of malfunction.
picture 2
(1) Power extension
(4) Dimmer
o Fit the power extension.
i Minimum diameter of ceiling opening for installation in false ceilings: 63 mm.
o Connect the power extension according to the connection diagram (picture 2).
i In the case of lighting systems with an output of more than 3500 W/VA, the installation
must divided across two circuit breakers with the same external conductor.
o If multiple circuit breakers supply dangerous voltages to the device or load, couple the
circuit breaker to ensure tripping.
2/4
82539913
J:0082539913 11.08.2010
Light Management
TRONIC amplifier, built-in
5 Appendix
5.1 Technical data
Rated voltage AC 230 V ~
Mains frequency 50 Hz
Ambient temperature +5 ... +45 °C
Housing temperature 70 °C (tc)
Power loss max. 10 W
Connected load at 25 °C
i Power specifications including transformer power dissipation.
Incandescent lamps 100 ... 700 W
HV halogen lamps 100 ... 700 W
Tronic transformers 100 ... 700 W
ohmic-capacitive 100 ... 700 W
Connection
Single stranded max. 4 mm²
finely stranded with conductor sleeve max. 1.5 mm²
Finely stranded max. 2.5 mm²
Number of power extensions max. 10
Total length power cable max. 100 m
Dimensions L×W×H 212×48.5×46 mm
The symbols used to label the dimmer load shows the load type that can be
connected to a dimmer and the electric behaviour of a load:
R = ohmic, C = capacitive
5.2 Troubleshooting
The power extension briefly switches its load off and on again.
Cause: short-circuit protection has tripped but now there is no longer a fault.
The power extension switches its load off and cannot be switched on again.
Cause 1: short-circuit protection has tripped.
Eliminate short-circuit.
Switch the power extension on again with the upstream dimmer.
i Short-circuit protection is not based on a conventional fuse, no metallic separation of the
operational current.
Cause 2: overheating protection has tripped.
Disconnect device from mains, also switch associated off circuit breakers.
Let device cool down for at least 15 minutes.
Check the installation situation.
Reduce the connected load.
Switch circuit breakers and device on again.
All the loads are switched off.
Cause: Device protection dimmer has tripped.
Check the dimmer.
3/4
82539913
J:0082539913 11.08.2010
Light Management
TRONIC amplifier, built-in


Produktspezifikationen

Marke: JUNG
Kategorie: Empfänger
Modell: 247EB

Brauchst du Hilfe?

Wenn Sie Hilfe mit JUNG 247EB benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Empfänger JUNG

Bedienungsanleitung Empfänger

Neueste Bedienungsanleitung für -Kategorien-