JUNG 1724DEB Bedienungsanleitung

JUNG Dimmer 1724DEB

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für JUNG 1724DEB (7 Seiten) in der Kategorie Dimmer. Dieser Bedienungsanleitung war für 8 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/7
LB Management
LB Management
LB Management
LB ManagementLB Management
Dimmer mini universal LED, Universal dimmer LED, built-in
Dimmer mini universal LED
Dimmer mini universal LED
Dimmer mini universal LED
Dimmer mini universal LEDDimmer mini universal LED
Art. no.: 1724DM
Universal dimmer LED, built-in
Universal dimmer LED, built-in
Universal dimmer LED, built-in
Universal dimmer LED, built-inUniversal dimmer LED, built-in
Art. no.: 1724DEB
Operating instructions
Operating instructions
Operating instructions
Operating instructionsOperating instructions
1
1
1
11 Safety instructions
Safety instructions
Safety instructions
Safety instructionsSafety instructions
Electrical devices may only be mounted and connected by electrically skilled persons.
Electrical devices may only be mounted and connected by electrically skilled persons.
Electrical devices may only be mounted and connected by electrically skilled persons.
Electrical devices may only be mounted and connected by electrically skilled persons.Electrical devices may only be mounted and connected by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Serious injuries, fire or property damage possible. Please read and follow manual fully.Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or load.
Danger of electric shock. Always disconnect before carrying out work on the devise or load.
Danger of electric shock. Always disconnect before carrying out work on the devise or load.
Danger of electric shock. Always disconnect before carrying out work on the devise or load.Danger of electric shock. Always disconnect before carrying out work on the devise or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load
Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load
Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load
Danger of electric shock. Device is not suitable for disconnection from supply voltage. The loadDanger of electric shock. Device is not suitable for disconnection from supply voltage. The load
is not electrically isolated from the mains even when the device is switched off.
is not electrically isolated from the mains even when the device is switched off.
is not electrically isolated from the mains even when the device is switched off.
is not electrically isolated from the mains even when the device is switched off.is not electrically isolated from the mains even when the device is switched off.
Risk of destruction if the set operating mode and load type do not match. Set correct operating
Risk of destruction if the set operating mode and load type do not match. Set correct operating
Risk of destruction if the set operating mode and load type do not match. Set correct operating
Risk of destruction if the set operating mode and load type do not match. Set correct operatingRisk of destruction if the set operating mode and load type do not match. Set correct operating
mode when connecting or exchanging the load.
mode when connecting or exchanging the load.
mode when connecting or exchanging the load.
mode when connecting or exchanging the load.mode when connecting or exchanging the load.
Fire hazard. For operation with inductive transformers, each transformer must be fused on the
Fire hazard. For operation with inductive transformers, each transformer must be fused on the
Fire hazard. For operation with inductive transformers, each transformer must be fused on the
Fire hazard. For operation with inductive transformers, each transformer must be fused on theFire hazard. For operation with inductive transformers, each transformer must be fused on the
primary side in accordance with the manufacturer's instructions. Only safety transformers ac-
primary side in accordance with the manufacturer's instructions. Only safety transformers ac-
primary side in accordance with the manufacturer's instructions. Only safety transformers ac-
primary side in accordance with the manufacturer's instructions. Only safety transformers ac-primary side in accordance with the manufacturer's instructions. Only safety transformers ac-
cording to EN 61558-2-6 may be used.
cording to EN 61558-2-6 may be used.
cording to EN 61558-2-6 may be used.
cording to EN 61558-2-6 may be used.cording to EN 61558-2-6 may be used.
These instructions are an integral part of the product, and must remain with the end customer.
These instructions are an integral part of the product, and must remain with the end customer.
These instructions are an integral part of the product, and must remain with the end customer.
These instructions are an integral part of the product, and must remain with the end customer.These instructions are an integral part of the product, and must remain with the end customer.
2
2
2
22 Intended use
Intended use
Intended use
Intended useIntended use
– Switching and dimming of lighting
– Dimmer mini universal LED: Mounting in appliance box according to DIN 49073 in com-
bination with a suitable cover or mounting in surface-mounted housing
– Universal dimmer LED, built-in: Mounting in false ceilings
– Operation is performed using the 2-wire or 3-wire extension with button cover, rotary dim-
mer extension or push-button with NO contact
3
3
3
33 Product characteristics
Product characteristics
Product characteristics
Product characteristicsProduct characteristics
– Device works according to the leading edge phase control or trailing edge phase control
principle
– Automatic or manual setting of the dimming principle suitable for the load
– Display of the set operating mode by means LED
– Operation without neutral conductor possible
– Switch-on via bulb-preserving soft start
– Switch on with last saved brightness or saved switch-on brightness
– Switch-on brightness can be saved permanently
– Minimum brightness can be saved permanently
– Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest
– Electronic over-temperature protection
Power extension possible by means of power boosters.
4
4
4
44 Operation
Operation
Operation
OperationOperation
Switch light
Switch light
Switch light
Switch lightSwitch light
For operation via the rotary dimmer extension, see the operation manual for the exten-
sion.
ï¿­ Press the button cover or push-button briefly.
1 / 7
82597213 10.05.2019
J0082597213
LB Management
LB Management
LB Management
LB ManagementLB Management
Dimmer mini universal LED, Universal dimmer LED, built-in
Adjust the brightness
Adjust the brightness
Adjust the brightness
Adjust the brightnessAdjust the brightness
Light is switched on.
ï¿­ Long press on button cover at the top or push-button.
The light gets brighter up to maximum brightness.
ï¿­ Long press on button cover or push-button.
Light gets darker to minimum brightness.
Push-button: The dimming direction is changed with each new long actuation.
Switch light on with minimum brightness
Switch light on with minimum brightness
Switch light on with minimum brightness
Switch light on with minimum brightnessSwitch light on with minimum brightness
ï¿­ Long press on button cover or push-button.
Save switch-on brightness
Save switch-on brightness
Save switch-on brightness
Save switch-on brightnessSave switch-on brightness
In the state as supplied, the switch-on brightness is set to maximum brightness.
ï¿­ Set light to the required brightness.
ï¿­ Press the button cover over entire surface for longer than 4 seconds.
Switch-on brightness is saved. For confirmation, the light is switched off briefly and
switched on again.
An push-button cannot be used to save the switch-on brightness.
Delete switch-on brightness
Delete switch-on brightness
Delete switch-on brightness
Delete switch-on brightnessDelete switch-on brightness
ï¿­ Press the button cover briefly: Light switches on at the saved switch-on brightness.
ï¿­ Press the button cover over entire surface for longer than 4 seconds.
The switch-on brightness is deleted. For confirmation, the light is switched off briefly and
switched on again. Switching on takes place at the last brightness value set.
A push-button cannot be used to delete the switch-on brightness.
5
5
5
55 Information for electrically skilled persons
Information for electrically skilled persons
Information for electrically skilled persons
Information for electrically skilled personsInformation for electrically skilled persons
5.1
5.1
5.1
5.15.1 Fitting and electrical connection
Fitting and electrical connection
Fitting and electrical connection
Fitting and electrical connectionFitting and electrical connection
DANGER!
Mortal danger of electric shock.
Mortal danger of electric shock.
Mortal danger of electric shock.
Mortal danger of electric shock.Mortal danger of electric shock.
Disconnect the device. Cover up live parts.
Disconnect the device. Cover up live parts.
Disconnect the device. Cover up live parts.
Disconnect the device. Cover up live parts.Disconnect the device. Cover up live parts.
2 / 7
82597213 10.05.2019
J0082597213
LB Management
LB Management
LB Management
LB ManagementLB Management
Dimmer mini universal LED, Universal dimmer LED, built-in
Fitting and electrical connection
Fitting and electrical connection
Fitting and electrical connection
Fitting and electrical connectionFitting and electrical connection
Figure1: Connection diagram
(1) Button Dimm-Mode
Dimm-Mode
Dimm-Mode
Dimm-ModeDimm-Mode
(2) LED display
(3) 2-wire extension
(4) 3-wire, rotary dimmer extension
(5) Push-button, NO contact
Connect 600 W LED lamps or compact fluorescent lamps at most per 16 A circuit
breaker. When connecting transformers, observe the data of the transformer manufac-
turer.
Our dimmers take into account the different electronic characteristics of most LED lamps
found on the market. However, it cannot be guaranteed that in individual cases the de-
sired results may not be achieved.
Operation without neutral conductor possible.
Only connect illuminated push buttons if they have a separate N terminal.
Figure2: Clampable conductor cross-section
3 / 7
82597213 10.05.2019
J0082597213


Produktspezifikationen

Marke: JUNG
Kategorie: Dimmer
Modell: 1724DEB

Brauchst du Hilfe?

Wenn Sie Hilfe mit JUNG 1724DEB benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Dimmer JUNG

Bedienungsanleitung Dimmer

Neueste Bedienungsanleitung für -Kategorien-