H0321400 Rev H
ENGLISH
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state
or local requirements exist. The maintainer must be a professional with sufficient experience in pool
equipment installation and maintenance so that all of the instructions in this manual can be followed
exactly. Before installing this product, read and follow all warning notices and instructions that accompany
this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can
cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the
installation, operation and safe use of this product. This information should be given to
the owner/operator of this equipment.
Jandy Pro Series Stealthâ„¢
WaterFall Pumps
Model SWF
INSTALLATION AND
OPERATION MANUAL
Page 2
ENGLISH Jandy® Pro Series Stealth™ WaterFall Pumps | Installation and Operation Manual
Table of Contents
DATE OF INSTALLATION
INSTALLER INFORMATION
INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)
PUMP MODEL HORSEPOWER
NOTES:
EQUIPMENT INFORMATION RECORD
Contents
Section 1. IMPORTANT SAFETY
INSTRUCTIONS 3 ...............................
1.1 Safety Instructions 3 ..............................................
1.2 Pool Pump Suction Entrapment Prevention
Guidelines 5 ..........................................................
Section 2. General Description 6 .......................
2.1 Introduction ......................................................... 6
2.2 Description ......................................................... 6
Section 3. Installation 6 .......................................
3.1 Plumbing ............................................................ 6
3.2 Electrical Installation 8 ...........................................
3.3 Pressure Testing ................................................. 9
Section 4. Operation ........................................11
4.1 Start-up ..............................................................11
Section 5. Service and Maintenance ..............11
5.1 Routine Maintenance ........................................11
5.2 Winterizing the Pump 12 .......................................
Section 6. Troubleshooting and Repair 13 ........
6.1 Troubleshooting ................................................ 13
6.2 Service Technician Maintenance ...................... 14
Section 7. Product Speciîš¿cations and
Technical Data 18 ..............................
7.1 Replacement Parts List 18 ....................................
7.2 Exploded View 18 ..................................................
7.3 SWF Pump Curves 19 ...........................................
7.4 PhysicalandOperationalSpecications .......... 19
Page 3
ENGLISH
Jandy® Pro Series Stealth™ WaterFall Pumps | Installation and Operation Manual
Section 1. IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
1.1 Safety Instructions
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the
following:
WARNING
To reduce the risk of injury, do not permit children to use this product.
WARNING
To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide, or full
ow)valvepositionwiththepumprunning.
WARNING
Jandy Pro Series pumps are powered by a high voltage electric motor and must be installed by a licensed or
certiedelectricianoraqualiedswimmingpoolservicetechnician.
WARNING
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH. Connect only to a branch circuit that is
protectedbyaground-faultcircuit-interrupter(GFCI).Contactaqualiedelectricianifyoucannotverifythatthe
circuit is protected by a GFCI. A GFCI should be provided by the installer and should be tested on a routine basis.
To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should
be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to
thepumpwithoutthetestbuttonbeingpushed,agroundcurrentisowing,indicatingthepossibilityofelectrical
shock.Donotusethepump.Disconnectthepumpandhavetheproblemcorrectedbyaqualiedservice
representative before using.
Duetothepotentialriskofre,electricshock,orinjuriestopersons,JandyProSeriesPumpsmustbeinstalledin
accordance with the National Electrical Code® (NEC®),alllocalelectricalandsafetycodes,andtheOccupational
Safety and Health Act (OSHA®).CopiesoftheNECmaybeorderedfromtheNationalFireProtectionAssociation ®
(NFPA®)onlineatwww.nfpa.orgorcall617-770-3000,orcontactyourlocalgovernmentinspectionagency.
WARNING
Incorrectlyinstalledequipmentmayfail,causingsevereinjuryorpropertydamage.
WARNING
• Do not connect the system to an unregulated city water system or other external source of pressurized water
producing pressures greater than 35 PSI.
• Trappedairinsystemcancausethelterlidtobeblownoff,whichcanresultindeath,seriouspersonalinjury,
or property damage. Be sure all air is out of the system before operating.
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN SERIOUS INJURY
OR DEATH. Do not block pump suction as this can cause severe injury or death. Do not use this pump for wading
pools, shallow pools or spas containing bottom drains, unless the pump is connected to at least two functioning
suctionoutlets.Suctionoutlet(drain)assemblies and covers must be certified to the latest published version of
ANSI®/ASME® A112.19.8, or its successor standard, ANSI/APSP-16.
Produktspezifikationen
Marke: | JANDY |
Kategorie: | pomp |
Modell: | WaterFall |
Brauchst du Hilfe?
Wenn Sie Hilfe mit JANDY WaterFall benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung pomp JANDY
21 August 2024
21 August 2024
21 August 2024
19 August 2024
19 August 2024
19 August 2024
19 August 2024
18 August 2024
18 August 2024
18 August 2024
Bedienungsanleitung pomp
- pomp Crivit
- pomp SilverCrest
- pomp SKS
- pomp Makita
- pomp Vonroc
- pomp Siemens
- pomp Powerfix
- pomp Black And Decker
- pomp Ryobi
- pomp Coleman
- pomp Einhell
- pomp Worx
- pomp Bartscher
- pomp Ultimate Speed
- pomp Eheim
- pomp Eurom
- pomp Hyundai
- pomp Fuxtec
- pomp Hazet
- pomp Metabo
- pomp Kärcher
- pomp Güde
- pomp Scheppach
- pomp Fieldmann
- pomp Wetelux
- pomp Westfalia
- pomp Vaillant
- pomp Husqvarna
- pomp Enermax
- pomp MSW
- pomp Germania
- pomp Fluval
- pomp Vetus
- pomp Jabsco
- pomp Sanibroyeur
- pomp Topeak
- pomp Hayward
- pomp Gre
- pomp Milwaukee
- pomp Toolcraft
- pomp Osram
- pomp Bestway
- pomp AL-KO
- pomp Gardena
- pomp Melinera
- pomp Powerplus
- pomp Blackburn
- pomp Lezyne
- pomp Alpha Tools
- pomp Sicce
- pomp Bulex
- pomp Danfoss
- pomp Comet
- pomp Hozelock
- pomp Ozito
- pomp Blumfeldt
- pomp Nibe
- pomp Sun Joe
- pomp Fluke
- pomp Nefit
- pomp Oase
- pomp POLARIS
- pomp Velda
- pomp Vivaria
- pomp Waldbeck
- pomp WHALE
- pomp AstralPool
- pomp Pedrollo
- pomp Esotec
- pomp T.I.P.
- pomp Panduit
- pomp Heissner
- pomp DAB
- pomp Abac
- pomp Baracuda
- pomp Ubbink
- pomp Liberty Pumps
- pomp Monzana
- pomp Lifan
- pomp Elpumps
- pomp For_Q
- pomp Simpson
- pomp Pontec
- pomp BluGarda
- pomp Grundfos
- pomp Zoeller
- pomp B-Air
- pomp Anova
- pomp Perlick
- pomp Fiap
- pomp Little Giant
- pomp Ebara
- pomp Basement Watchdog
- pomp Barwig
- pomp Wayne
- pomp Ribimex
- pomp Maruyama
- pomp ESPA
- pomp Hollex
- pomp Sauermann
- pomp Eco-Flo
- pomp Nowax
- pomp EvoHeat
- pomp Zéfal
- pomp OSIP
- pomp Franklin Electric
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
13 Oktober 2024
7 Oktober 2024
2 Oktober 2024
1 Oktober 2024