JANDY JEP-R Bedienungsanleitung

JANDY pomp JEP-R

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für JANDY JEP-R (60 Seiten) in der Kategorie pomp. Dieser Bedienungsanleitung war für 17 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/60
H0412200 Rev J
ENGLISH | FRAN AIS | ESPAÑOLÇ
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state
or local requirements exist. The maintainer must be a professional with sufficient experience in pool
equipment installation and maintenance so that all of the instructions in this manual can be followed
exactly. Before installing this product, read and follow all warning notices and instructions that accompany
this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can
cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the
installation, operation and safe use of this product. This information should be given to
the owner/operator of this equipment.
INSTALLATION AND
OPERATION MANUAL
Jandy Pro Series
JEP-R
Variable-Speed Pump Digital Controller
For use with Jandy Pro Series Variable-Speed Pumps
For Indoor or Outdoor Installations
Table of Contents
DATE OF INSTALLATION
INSTALLER INFORMATION
INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)
PUMP MODEL HORSEPOWER
FILTER MODEL SERIAL NUMBER
CONTROLLER MODEL SERIAL NUMBER
NOTES:
EQUIPMENT INFORMATION RECORD
Section 1. IMPORTANT
SAFETY INSTRUCTIONS 3 ...................
1.1 Safety Instructions 3 .............................................
1.2 Pool Pump Suction Entrapment Prevention
Guidelines 6 ..........................................................
Section 2. Installation of the
Digital Controller 7 ................................
2.1 Introduction ........................................................7
2.2 The Controller Panel 7 ..........................................
2.3 The Controller Components 7 ...............................
2.3.1 Additional materials 8 .....................................
2.4 Installation of the Backplate
onto an Electrical Box 8 ........................................
2.5 Installation of the Backplate
on a Flat Wall 8 .....................................................
2.6 Connection to Jandy® Pro Series
variable-speed Pump 8 .........................................
2.7 Variable Speed Pump Switch Settings 9 ..............
2.8 Connection to Remote Contacts 9 ........................
2.9 Remote Operation 10 .............................................
2.10 Remote Closure 4 Behavior 10 ...............................
2.11 Remote Closure 4 Application
- Booster Pump Support 10 ....................................
Section 3. User Operation of the Variable-Speed
Controller ............................................ 11
3.1 The Controller Interface .....................................11
3.2 Basic Functions .................................................11
3.3 OFF Mode ..........................................................11
3.4 RUN Mode .........................................................11
3.5 Manual Start and Stop 12 .......................................
3.6 Pump Speed Setting 12 ..........................................
3.7 Timeclock Setup and Operation.........................12
3.8 Keypad Lock 13 ......................................................
Section 4. Service Setup Options 13 .......................
4.1 Entering Service Setup 13 ......................................
4.2 Minimum and Maximum Pump Speeds 13 .............
4.3 Load Defaults 14 .....................................................
4.4 Last Fault 14 ...........................................................
4.5 Priming Speed and Duration 14 ..............................
4.6 eStar Speed 15 .......................................................
4.7 Pump Freeze Protect Operation 15 ........................
4.8 Selecting Pump Type .........................................15
4.9 Display Power Usage 15 ........................................
Section 5. User Set Up Options 16 ...........................
5.1 Setting Time-of-Day ...........................................16
5.2 Labeling Speeds 16 ................................................
5.3 General Labels 16 ..................................................
5.4 Custom Labels 16 ...................................................
5.5 Display Light Control 16 ..........................................
5.6 Language Selection 17 ...........................................
5.7 Run Duration (Speeds 3 and 4 Only) 17 .................
5.8 Password Protect 17 ...............................................
Section 6. Menu Flow Chart 18 .................................
PAGE 2
ENGLISH JEP-R Variable-Speed Pump Controller | Installation Manual
Section 1. IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
1.1 Safety Instructions
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the
following:
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN SERIOUS
INJURY OR DEATH. Do not block pump suction, as this can cause severe injury or death. Do not
use this pump for wading pools, shallow pools, or spas containing bottom drains, unless the pump is
connected to at least two (2) functioning suction outlets. Drain covers must be certified to the latest
published edition of ANSI®/ASME® A112.19.8 or its successor standard, ANSI/APSP-16.
WARNING
To reduce the risk of injury, do not permit children to use this product.
WARNING
To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide,
or full flow) valve position with the pump running.
WARNING
To reduce the risk of injury, do not remove the suction fittings of your spa or hot tub. Never operate a spa or hot tub if
the suction fittings are broken or missing. Never replace a suction fitting with one rated less than the flow rate marked
on the equipment assembly.
WARNING
Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when the internal temperature
of the body reaches a level several degrees above the normal body temperature of 98.6°F (37°C). The symptoms
of hyperthermia include dizziness, fainting, drowsiness, lethargy, and an increase in the internal temperature of
the body. The effects of hyperthermia include: 1) unawareness of impending danger; 2) failure to perceive heat;
3) failure to recognize the need to exit spa; 4) physical inability to exit spa; 5) fetal damage in pregnant women;
6) unconsciousness resulting in a danger of drowning.
WARNING
To Reduce the Risk of Injury -
a The water in a spa should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and 104°F )
(40°C) are considered safe for a healthy adult. Lower water temperatures are recommended for young children
and when spa use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing fetal damage during the early months of
pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to 100°F (38°C).
c) Before entering a spa or hot tub, the user should measure the water temperature with an accurate thermometer
since the tolerance of water temperature-regulating devices varies.
d) The use of alcohol, drugs, or medication before or during spa or hot tub use may lead to unconsciousness with
the possibility of drowning.
e) Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system
problems, or diabetes should consult a physician before using a spa.
f) Persons using medication should consult a physician before using a spa or hot tub since some medication may
induce drowsiness while other medication may affect heart rate, blood pressure, and circulation.
PAGE 3
ENGLISH
JEP-R Variable-Speed Pump Controller | Installation Manual


Produktspezifikationen

Marke: JANDY
Kategorie: pomp
Modell: JEP-R

Brauchst du Hilfe?

Wenn Sie Hilfe mit JANDY JEP-R benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung pomp JANDY

Bedienungsanleitung pomp

Neueste Bedienungsanleitung für -Kategorien-