JANDY Stealth Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für JANDY Stealth (60 Seiten) in der Kategorie Pumpe. Dieser Bedienungsanleitung war für 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/60

Jandy Stealthâ„¢ Pumps
Models SHPF and SHPM
H0573800 Rev V
ENGLISH | FRANÇAIS | ESPAÑOL
INSTALLATION AND
OPERATION MANUAL
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state
or local requirements exist. The maintainer must be a professional with sufficient experience in pool
equipment installation and maintenance so that all of the instructions in this manual can be followed
exactly. Before installing this product, read and follow all warning notices and instructions that accompany
this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation may void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can
cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the
installation, operation and safe use of this product. This information should be given to
the owner/operator of this equipment.

Table of Contents
Section 1. IMPORTANT SAFETY
INSTRUCTIONS 3 ..............................
1.1 Safety Instructions 3 ............................................
1.2 Pool Pump Suction Entrapment Prevention
Guidelines 5 ........................................................
Section 2. General Description 6 ......................
2.1 Introduction ....................................................... 6
2.2 Description ....................................................... 6
Section 3. Installation 6 ......................................
3.1 Plumbing .......................................................... 6
3.2 Electrical Installation 8 .........................................
3.3 Pressure Testing ............................................. 10
Section 4. Operation 12 ......................................
4.1 Start-up ........................................................... 12
Section 5. Service and Maintenance 13 ............
5.1 Routine Maintenance 13 .....................................
5.2 Winterizing the Pump 13 .....................................
Section 6. Troubleshooting 14 ..........................
6.1 Troubleshooting .............................................. 14
Section 7. Product Speciîš¿cations and
Technical Data 15 .............................
7.1 Replacement Parts List 15 ..................................
7.2 Exploded View 16 ................................................
7.3 SHPF and SHPM Pump Curves 17 .....................
7.4 PhysicalandOperationalSpecications ........ 17
DATE OF INSTALLATION
INSTALLER INFORMATION
INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)
PUMP MODEL HORSEPOWER
NOTES:
EQUIPMENT INFORMATION RECORD
Page 2 ENGLISH
Jandy® Stealth™ Pumps | Operation Manual

Section 1. IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
1.1 Safety Instructions
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the
following:
Page 3
ENGLISH
Jandy® Stealth™ Pumps | Operation Manual
WARNING
To reduce the risk of injury, do not permit children to use this product.
WARNING
To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide, or full
ow)valvepositionwiththepumprunning.
WARNING
Jandypumpsarepoweredbyahighvoltageelectricmotorandmustbeinstalledbyalicensedorcertiedelec-
tricianoraqualiedswimmingpoolservicetechnician.
WARNING
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH (For all permanently installed units
intended for use on 15 or 20 ampere, 120 through 240 volt, single phase branch circuits). Connect only
toabranchcircuitthatisprotectedbyaground-faultcircuit-interrupter(GFCI).Contactaqualiedelectricianif
you cannot verify that the circuit is protected by a GFCI. A GFCI should be provided by the installer and should
be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the
reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the
GFCIinterruptspowertothepumpwithoutthetestbuttonbeingpushed,agroundcurrentisowing,indicating
the possibility of electrical shock. Do not use the pump. Disconnect the pump and have the problem corrected by
aqualiedservicerepresentativebeforeusing.
Duetothepotentialriskofre,electricshock,orinjuriestopersons,JandyPumpsmustbeinstalledinaccor-
dance with the National Electrical Code® (NEC®),alllocalelectricalandsafetycodes,andtheOccupationalSafe-
ty and Health Act (OSHA®).CopiesoftheNECmaybeorderedfromtheNationalFireProtectionAssociation ®
(NFPA®)onlineatwww.nfpa.orgorcall617-770-3000,orcontactyourlocalgovernmentinspectionagency.
WARNING
Incorrectly installed equipment may fail, causing severe injury or property damage.
WARNING
• Do not connect the system to an unregulated city water system or other external source of pressurized water
producing pressures greater than 35 PSI.
• Trappedairinsystemcancausethelterlidtobeblownoff,whichcanresultindeath,seriouspersonalinjury,
or property damage. Be sure all air is out of the system before operating.
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN SERIOUS INJURY
OR DEATH. Do not block pump suction as this can cause severe injury or death. Do not use this pump for wading
pools, shallow pools or spas containing bottom drains, unless the pump is connected to at least two functioning
suctionoutlets.Suctionoutlet(drain)assembliesandcoversmustbecertifiedtothelatestpublishedversionof
ANSI®/ASME® A112.19.8, or its successor standard, ANSI/APSP-16.
Produktspezifikationen
Marke: | JANDY |
Kategorie: | Pumpe |
Modell: | Stealth |
Brauchst du Hilfe?
Wenn Sie Hilfe mit JANDY Stealth benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Pumpe JANDY

1 April 2024

16 Dezember 2023

7 Dezember 2023

26 August 2023
Bedienungsanleitung Pumpe
- Pumpe Crivit
- Pumpe SilverCrest
- Pumpe SKS
- Pumpe Quigg
- Pumpe Makita
- Pumpe Parkside
- Pumpe Vonroc
- Pumpe Siemens
- Pumpe Powerfix
- Pumpe Trotec
- Pumpe Outwell
- Pumpe Einhell
- Pumpe Bartscher
- Pumpe Telestar
- Pumpe Tacklife
- Pumpe Ultimate Speed
- Pumpe Eheim
- Pumpe Eurom
- Pumpe Hyundai
- Pumpe Fuxtec
- Pumpe Metabo
- Pumpe Kärcher
- Pumpe Güde
- Pumpe Biltema
- Pumpe Fieldmann
- Pumpe Enermax
- Pumpe Michelin
- Pumpe Florabest
- Pumpe Germania
- Pumpe Zipper
- Pumpe EUFAB
- Pumpe Jabsco
- Pumpe Sanibroyeur
- Pumpe Batavia
- Pumpe Topeak
- Pumpe Hayward
- Pumpe Milwaukee
- Pumpe Toolcraft
- Pumpe Osram
- Pumpe Bestway
- Pumpe AL-KO
- Pumpe Gardena
- Pumpe Verto
- Pumpe Powerplus
- Pumpe Cannondale
- Pumpe Lezyne
- Pumpe Neptun
- Pumpe Sicce
- Pumpe Danfoss
- Pumpe Hozelock
- Pumpe Ozito
- Pumpe Ferroli
- Pumpe Nibe
- Pumpe Sun Joe
- Pumpe Fluke
- Pumpe Generac
- Pumpe Lavorwash
- Pumpe Oase
- Pumpe OKAY
- Pumpe Plantiflor
- Pumpe Velda
- Pumpe Waldbeck
- Pumpe Zodiac
- Pumpe AstralPool
- Pumpe T.I.P.
- Pumpe Heissner
- Pumpe DAB
- Pumpe Baracuda
- Pumpe Rule
- Pumpe Park Tool
- Pumpe Lifan
- Pumpe Elpumps
- Pumpe For_Q
- Pumpe Simpson
- Pumpe Pontec
- Pumpe BluGarda
- Pumpe Grundfos
- Pumpe Superior Pump
- Pumpe Zoeller
- Pumpe SHURflo
- Pumpe Ergotools Pattfield
- Pumpe Ebara
- Pumpe Basement Watchdog
- Pumpe Madimack
- Pumpe Barwig
- Pumpe Wayne
- Pumpe SANDPIPER
- Pumpe Zehnder Pumpen
Neueste Bedienungsanleitung für -Kategorien-

26 Juni 2024

26 Juni 2024

26 Juni 2024

26 Juni 2024

25 Juni 2024

14 Juni 2024

4 Juni 2024

4 Juni 2024