JANDY FloPro Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für JANDY FloPro (16 Seiten) in der Kategorie Pumpe. Dieser Bedienungsanleitung war für 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/16
H0315300 Rev R
ENGLISH
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state
or local requirements exist. The maintainer must be a professional with sufficient experience in pool
equipment installation and maintenance so that all of the instructions in this manual can be followed
exactly. Before installing this product, read and follow all warning notices and instructions that accompany
this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can
cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the
installation, operation and safe use of this product. This information should be given to
the owner/operator of this equipment.
Jandy® Pro Series Pumps
Model FHPM
INSTALLATION AND
OPERATION MANUAL
Page 2
ENGLISH Jandy® Pro Series FHPM Pump | Installation & Operation Manual
Table of Contents
EQUIPMENT INFORMATION RECORD
DATE OF INSTALLATION
INSTALLER INFORMATION
INITIAL PRESSURE GAUGE READING (WITH CLEAR FILTER)
PUMP MODEL HORSEPOWER
NOTES:
Section 1. Important Safety Instructions 3 .........
1.1 Safety Instructions 3 ..............................................
1.2 Pool Pump Suction Entrapment Prevention
Guidelines 5 ..........................................................
Section 2. General Description 6 .......................
2.1 Introduction ......................................................... 6
2.2 Description ......................................................... 6
Section 3. Installation 6 .......................................
3.1 Plumbing ............................................................ 6
3.2 Electrical Installation 9 ...........................................
3.3 Pressure Testing ................................................11
Section 4. Operation ........................................11
4.1 Start-up ..............................................................11
Section 5. Service and Maintenance ..............11
5.1 Routine Maintenance ........................................11
5.2 Winterizing the Pump 12 .......................................
Section 6. Troubleshooting 12 ...........................
6.1 Troubleshooting ................................................ 13
Section 7. Product Speciîš¿cations and
Technical Data 14 ..............................
7.1 Replacement Parts List 14 ....................................
7.2 FHP Exploded View 15 ..........................................
7.3 Performance Curves 15 ........................................
7.4 PhysicalandOperationalSpecications .......... 16
Page 3
ENGLISH
Jandy® Pro Series FHPM Pump | Installation & Operation Manual
Section 1. Important Safety Instructions
READ AND FOLLOW ALL INSTRUCTIONS
1.1 Safety Instructions
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the
following:
WARNING
To reduce the risk of injury, do not permit children to use this product.
WARNING
To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide, or full
ow)valvepositionwiththepumprunning.
WARNING
Jandy Pro Series pumps are powered by a high voltage electric motor and must be installed by a licensed or
certiedelectricianoraqualiedswimmingpoolservicetechnician.
WARNING
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH. Connect only to a branch circuit that is
protectedbyaground-faultcircuit-interrupter(GFCI).Contactaqualiedelectricianifyoucannotverifythatthe
circuit is protected by a GFCI. A GFCI should be provided by the installer and should be tested on a routine basis.
To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should
be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to
thepumpwithoutthetestbuttonbeingpushed,agroundcurrentisowing,indicatingthepossibilityofelectrical
shock.Donotusethepump.Disconnectthepumpandhavetheproblemcorrectedbyaqualiedservice
representative before using.
Duetothepotentialriskofre,electricshock,orinjuriestopersons,JandyProSeriesPumpsmustbeinstalledin
accordance with the National Electrical Code® (NEC®),alllocalelectricalandsafetycodes,andtheOccupational
Safety and Health Act (OSHA®).CopiesoftheNECmaybeorderedfromtheNationalFireProtectionAssociation ®
(NFPA®)onlineatwww.nfpa.orgorcall617-770-3000,orcontactyourlocalgovernmentinspectionagency.
WARNING
Incorrectlyinstalledequipmentmayfail,causingsevereinjuryorpropertydamage.
WARNING
• Do not connect the system to an unregulated city water system or other external source of pressurized water
producing pressures greater than 35 PSI.
• Trappedairinsystemcancausethelterlidtobeblownoff,whichcanresultindeath,seriouspersonalinjury,
or property damage. Be sure all air is out of the system before operating.
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN SERIOUS INJURY
OR DEATH. Do not block pump suction as this can cause severe injury or death. Do not use this pump for wading
pools, shallow pools or spas containing bottom drains, unless the pump is connected to at least two functioning
suctionoutlets.Suctionoutlet(drain)assemblies and covers must be certified to the latest published version of
ANSI®/ASME® A112.19.8, or its successor standard, ANSI/APSP-16.
Produktspezifikationen
Marke: | JANDY |
Kategorie: | Pumpe |
Modell: | FloPro |
Brauchst du Hilfe?
Wenn Sie Hilfe mit JANDY FloPro benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Pumpe JANDY
1 April 2024
Bedienungsanleitung Pumpe
- Pumpe Crivit
- Pumpe SKS
- Pumpe Quigg
- Pumpe Vonroc
- Pumpe Siemens
- Pumpe Powerfix
- Pumpe Outwell
- Pumpe Einhell
- Pumpe Bartscher
- Pumpe Tacklife
- Pumpe Ultimate Speed
- Pumpe Eheim
- Pumpe Hyundai
- Pumpe Metabo
- Pumpe Kärcher
- Pumpe Güde
- Pumpe Fieldmann
- Pumpe Enermax
- Pumpe Florabest
- Pumpe Zipper
- Pumpe EUFAB
- Pumpe Jabsco
- Pumpe Batavia
- Pumpe Topeak
- Pumpe Hayward
- Pumpe Milwaukee
- Pumpe Toolcraft
- Pumpe Bestway
- Pumpe AL-KO
- Pumpe Gardena
- Pumpe Powerplus
- Pumpe Cannondale
- Pumpe Lezyne
- Pumpe Neptun
- Pumpe Nibe
- Pumpe Sun Joe
- Pumpe Fluke
- Pumpe Generac
- Pumpe Lavorwash
- Pumpe Oase
- Pumpe OKAY
- Pumpe Plantiflor
- Pumpe Waldbeck
- Pumpe Zodiac
- Pumpe AstralPool
- Pumpe T.I.P.
- Pumpe Heissner
- Pumpe DAB
- Pumpe Park Tool
- Pumpe Elpumps
- Pumpe For_Q
- Pumpe Simpson
- Pumpe Pontec
- Pumpe Grundfos
- Pumpe Superior Pump
- Pumpe Zoeller
- Pumpe Ergotools Pattfield
- Pumpe Ebara
- Pumpe Basement Watchdog
- Pumpe Madimack
- Pumpe Barwig
- Pumpe Wayne
- Pumpe SANDPIPER
- Pumpe Zehnder Pumpen
Neueste Bedienungsanleitung für -Kategorien-
26 Juni 2024
26 Juni 2024
26 Juni 2024
26 Juni 2024
25 Juni 2024
14 Juni 2024
4 Juni 2024
4 Juni 2024