Seite 1/2
P/N - 466 2316 • REV D OCT12 1 •
DesignLine Recessed Door Contact Installation
Instructions
Introduction
This is the DesignLine Recessed Door Contact Installation
Instructions for model TX- - -1. The TX- - -1 is the 1510 01 1510 01
industry’s mos t flexible supervised, recessed door contact
allowing a multitude of applications while hiding the transmitter
within a door frame. The contact uses a replaceable lithium
battery and should last five years under normal usage.
The contact comes with a standard flush-mount top and a
flanged top. Unscrew the top to access the battery or change
to a different top.
Battery installation
To install the battery, do the following:
1. Unscrew the top of the contact.
2. Carefully pull the circuit board out (Figure 1 ) of the below
contact. Before removing the circuit board, notice that it
fits inside a channel on the inside of the case. Do not pull
the circuit board unit by the antenna wire.
Caution: You must be free of static electricity before handling
sensor circuit boards. Touch a grounded, bare metal surface
before touching circuit boards or wear a grounding strap.
Figure 1: Battery installation
3. Slide the battery onto the circuit board unit with the plus
(+) side up.
4. Slide the circuit board unit into the contact. Make sure you
slide it back into the channel guides for proper fit with the
tamper switch facing up.
5. Screw the top back on the contact.
When replacing batteries, use only Panasonic Lithium CR23
batteries for replacement.
WARNING: The battery may explode if mistreated. Do not
recharge, disassemble, or dispose of in fire.
Mounting
It is important to select the proper placement of the recessed
transmitter and magnet. The transmitter has two separate tops
that allow a flush mount or screw mount in case you accidently
over drill the hole or require extra support to ensure the
transmitter does not move. The magnet does not have a
second flanged top so you must be careful to ensure that the
magnet is tightly in place once installed.
To mount the transmitter and magnet, do the following:
1. Install the CR2 battery if you have not already done so
(Figure 1 above ).
2. Select a location on the door frame for the TX- - -1510 01 1
transmitter and magnet to be installed (Figure 2 on page
2). Use a marker to mark the placement and ensure that
the two holes you intend to drill are lined up directly across
from each other.
Tamper
sw itch
Antenna
Contact
Battery
Circuit
board
2 DesignLine Recessed Door Contact Installation Instructions
Figure 2: Mounting
Note: This is only one mounting option. You should select
the best mounting method based on the application.
3. Using an 7/8 in. drill bit, slowly drill the first hole for the
magnet. The TX- - -1 was specifically designed to 1510 01
be slightly larger than an 7/8 in. hole so you will need to
carefully drill to fit by slowly routing the hole little by little to
ensure a snug fit.
4. Using a 7/8 in. drill bit, drill the mating hole for the
transmitter and use either the standard flush-mount cap
and insert the transmitter for a snug fit, or use the flanged
cap and use the screws provided to mount the transmitter
to the door frame.
Enrolling
The following section describes general guidelines for
programming (learning) the sensor into the panel’s memory.
Refer to you panel documentation for complete programming
details.
To program (learn) the contact into the panel, do the following:
1. Unscrew the top of the contact.
2. Set the panel into program mode.
3. Refer to your panel documentation for instructions for
learning sensors.
4. Press and release the tamper switch on the top of the
contact circuit board (Figure 1 on page 1)until the panel
responds.
5. Replace the contact top.
6. Exit program mode.
Specifications
Battery
CR2032, 3 VDC, 225 mAh, Lithium Coin Cell
Typical battery life
5 to 8 years
Transmitter frequency
319.508 MHz (crystal-controlled)
Transmitter frequency
tolerance
± 8 kHz
Bandw idth
24 kHz
Modulation type
Amplitude shift key (ASK)
Unique ID codes
16 million
Peak field strength
Typical 35,000 uV/m at 3 m
Supervisory interval
64 minutes
Operating temperature
10 to 120°F (-12 to 49°C)
Enclosure
PC- 540
Weight
0.63 oz. (18 g)
Dimensions (L x W x
H)
1.70 x 1.10 x 0.91 in. (4.32 x 2.76 x 2.32 cm)
Color
Belgian gray
Regulatory information
FCC compliance
This device complies w ith part 15 of the FCC
rules. Operation is subject to the follow ing
conditions:
1. This device may not cause harmful
interference.
2. This device must accept any interference
received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved
by the party responsible for compliance could
void the user’s authority to operate the
equipment.
FCC ID: B4Z- - - TX 1510 01
Industry Canada ID: 1175C-TX151001
Contact information
www.utcfireandsecurity.com or www.interlogix.com
For customer support, see www.interlogix.com/customer-
support
© 2012 UTC Fire & Security Americas Corporation, Inc.
Interlogix is part of UTC Climate Controls & Security, a unit of
United Technologies Corporation. All rights reserved.
Produktspezifikationen
Marke: | Interlogix |
Kategorie: | Tür-/Rahmensensor |
Modell: | TX-1510-01-1 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Interlogix TX-1510-01-1 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Tür-/Rahmensensor Interlogix
26 Juli 2024
Bedienungsanleitung Tür-/Rahmensensor
- Tür-/Rahmensensor Hama
- Tür-/Rahmensensor Bosch
- Tür-/Rahmensensor Schwaiger
- Tür-/Rahmensensor EMOS
- Tür-/Rahmensensor König
- Tür-/Rahmensensor Caliber
- Tür-/Rahmensensor Abus
- Tür-/Rahmensensor Avidsen
- Tür-/Rahmensensor EZVIZ
- Tür-/Rahmensensor Olympia
- Tür-/Rahmensensor Nexa
- Tür-/Rahmensensor Marmitek
- Tür-/Rahmensensor Techly
- Tür-/Rahmensensor Chamberlain
- Tür-/Rahmensensor Kidde
- Tür-/Rahmensensor Optex
- Tür-/Rahmensensor Speed-Link
- Tür-/Rahmensensor Hikvision
- Tür-/Rahmensensor Homematic IP
- Tür-/Rahmensensor KlikaanKlikuit
- Tür-/Rahmensensor Satel
- Tür-/Rahmensensor Steren
- Tür-/Rahmensensor X4-Tech
- Tür-/Rahmensensor Sonoff
- Tür-/Rahmensensor Inovonics
- Tür-/Rahmensensor Axis
- Tür-/Rahmensensor Fibaro
- Tür-/Rahmensensor ORNO
- Tür-/Rahmensensor DSC
- Tür-/Rahmensensor Tellur
- Tür-/Rahmensensor Kanlux
- Tür-/Rahmensensor Gewiss
- Tür-/Rahmensensor Setti+
Neueste Bedienungsanleitung für -Kategorien-
7 Oktober 2024
18 September 2024
13 September 2024
13 September 2024
6 September 2024
6 September 2024
5 September 2024
5 September 2024
5 September 2024
5 September 2024