HQ EL-EPM02 Bedienungsanleitung
HQ
EnergiekostenzÀhler
EL-EPM02
Lesen Sie kostenlos die đ deutsche Bedienungsanleitung fĂŒr HQ EL-EPM02 (61 Seiten) in der Kategorie EnergiekostenzĂ€hler. Dieser Bedienungsanleitung war fĂŒr 15 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/61
English Deutsch Français Nederlands Italiano Español Magyar Suomi Svenska Äesky RomĂąnÄ ÎλληΜÎčÎșÎŹ
1
EL-EPM02HQ
MANUAL (p. 2)
Energy meter
MODE DâEMPLOI (p. 12)
Compteur Ă©lectrique
MANUALE (p. 22)
Misuratore di energia
BRUKSANVISNING (s. 42)
EnergimÀtare
MANUAL DE UTILIZARE (p. 52)
Aparat de mÄsurÄ a consumului electric
HASZNĂLATI ĂTMUTATĂ (o. 32.)
EnergiamĂ©rĆ
KĂYTTĂOHJE (s. 37)
Energiamittari
GEBRUIKSAANWIJZING (p. 17)
Energiemeter
ANLEITUNG (s. 7)
Energiekosten-MessgerÀt
MANUAL DE USO (p. 27)
MultĂmetro elĂ©ctrico
NĂVOD K POUĆœITĂ (s. 47)
ElektromÄr
ÎÎΧÎÎÎĄÎÎÎÎ XPHÎŁHÎŁ (ÏΔλ. 57)
ÎΔÏÏηÏÎźÏ Î”ÎœÎÏγΔÎčαÏ
English
Deutsch
FrançaisNederlandsItalianoEspañolMagyarSuomiSvenskaÄeskyRomĂąnÄÎλληΜÎčÎșÎŹ
2
ENGLISH
Introduction:
Plug-In (French/Belgium version) Mains Power and Energy Monitor. Measures voltage
(V), Ampere (A), Watts (W), Volt-Ampere(VA), Hertz (Hz) and power factor (PF). Ideal
to check how much power your appliances are consuming.
Operation:
FUNC
SET
SET
Master clear
Display
General features:
Display current clock1)
Display line voltage2)
Display line current3)
Display line power4)
Display and memory peak line power5)
Display and memory accumulative total electric quantity6)
Display and memory total on time and total electric charge7)
Display and memory total on time and total electric charge of price18)
Display and memory total on time and total electric charge of price29)
Display line frequency10)
Display power factor11)
Adjustable max. overload current, max. overload warning12)
Adjustable price / kWh13)
11 combinations of day or blocks of days available as follows: MO/ TU/ WE/ TH/ FR/
SA/ SU/ MO, TU, WE, TH, FR/ MO, TU, WE, TH, FR, SA/ SA, SU/ MO, TU, WE, TH,
FR, SA, SU
English Deutsch Français Nederlands Italiano Español Magyar Suomi Svenska Äesky RomĂąnÄ ÎλληΜÎčÎșÎŹ
3
The data base:
Press FUNC button the data displays as follows:
VOLTvac â AMP â WATT â MAX WATT â KWh â TOTAL PRICE;
TOTAL ON TIME â PRICE1 â PRICE2
The meter will display current clock and line voltage, frequency, if plug in socket 1)
after insert battery without any operation
Press FUNC button once and release, the meter will display current clock and line 2)
current, power factor
Press FUNC button once again and release, the meter will display current clock 3)
and real power, power factor
Press FUNC button once again and release, the meter will display max. line 4)
power and the appear time of max. line power, power factor. Press and hold
FUNC button for 5 seconds will clear max. line power display during this state
Press FUNC button once again and release, the meter will display current clock 5)
and accumulative power factor
Press FUNC button once again and release, the meter will display total on time 6)
and total electrical charge
Press FUNC button once again and release, the meter will display total on time of 7)
price 1 and total electrical charge of price 1
Press FUNC button once again and release, the meter will display total on time of 8)
price 2 and total electric charge of price 2
Press FUNC button once again and release, the meter will come back to display 9)
current time and line voltage. Press and hold FUNC button for 5 seconds to clear
accumulative total electric quantity and total electric charge during display state
of total electric charge or total electric charge of price 1 or total electric charge of
price 2
LCD display 10) â when total electric quantity, total electric charge overîow, the
OVER will îash at the same time
Setting current clock:
Press FUNC button until the CLOCK displays in LCD1)
Press SET button once time, the WEEK DAY will îash at the same time, the clock 2)
change to SET mode, you can set the current clock
Press UP button to set the WEEK DAY3)
Press SET button once time again and release, the HOUR will îash the WEEK 4)
DAY will stop îashing and keep display
Press UP button to set the HOUR5)
Press SET button once time again and release, the MINUTE will îash, the HOUR 6)
will stop îashing and keep display
Press UP button to set the MINUTE7)
Press SET button once time again and release, the time come back to CLOCK 8)
display mode
Press UP button during the CLOCK display state, change 12-24 hour mode. 9)
To reset incorrect time, repeat all above steps. After îżnish setting, plug the meter
into a regular 230/240V power outlet, plug in an appliance that you want to use
and turn the mains power on. Now the meter begins to measure the consumption
of the appliance and detect the equipment that uses too much electricity at once
Produktspezifikationen
Marke: | HQ |
Kategorie: | EnergiekostenzÀhler |
Modell: | EL-EPM02 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit HQ EL-EPM02 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung EnergiekostenzÀhler HQ
14 Juli 2024
Bedienungsanleitung EnergiekostenzÀhler
- EnergiekostenzÀhler Hama
- EnergiekostenzÀhler Quigg
- EnergiekostenzÀhler Velleman
- EnergiekostenzÀhler Schwaiger
- EnergiekostenzÀhler Cresta
- EnergiekostenzÀhler EMOS
- EnergiekostenzÀhler Technoline
- EnergiekostenzÀhler Schneider
- EnergiekostenzÀhler Vivanco
- EnergiekostenzÀhler Elro
- EnergiekostenzÀhler Easy Home
- EnergiekostenzÀhler Globaltronics
- EnergiekostenzÀhler Aeon Labs
- EnergiekostenzÀhler EnerGenie
- EnergiekostenzÀhler GEO Ensemble
- EnergiekostenzÀhler Sitecom
- EnergiekostenzÀhler T.I.P.
- EnergiekostenzÀhler Chacon
- EnergiekostenzÀhler ORNO
- EnergiekostenzÀhler MDT
- EnergiekostenzÀhler Efergy
Neueste Bedienungsanleitung fĂŒr -Kategorien-
26 September 2024
26 September 2024
6 September 2024
6 September 2024
6 September 2024
5 September 2024
4 September 2024
4 September 2024
31 August 2024
29 August 2024