Honeywell OMNI-408 Bedienungsanleitung


Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Honeywell OMNI-408 (32 Seiten) in der Kategorie Sicherheit. Dieser Bedienungsanleitung war fĂĽr 11 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/32
N9942-2V2 4/04 Rev. A
FBII Security System
FBII Security SystemFBII Security System
FBII Security System
O
OO
O
O
OO
OM
MM
M
M
MM
MN
NN
N
N
NN
NI
II
I
I
II
I®-
--
-
-
--
-4
44
4
4
44
40
00
0
0
00
08
88
8
8
88
8
O
OO
O
O
OO
OM
MM
M
M
MM
MN
NN
N
N
NN
NI
II
I
I
II
I®-
--
-
-
--
-4
44
4
4
44
40
00
0
0
00
08
88
8
8
88
8E
EE
E
E
EE
EU
UU
U
U
UU
U
User Guide
– 2 –
– 3 –
Table Of Contents
QUICK REFERENCE.............................................................................................4
Arming the System............................................................................................4
Disarming the System ....................................................................................... 4
Arm System/Stay Inside....................................................................................4
Arm System/Stay Inside/Instant Mode..............................................................4
Smoke Detector Reset ......................................................................................4
INTRODUCTION.................................................................................................... 6
SYSTEM REFERENCE .........................................................................................7
SYSTEM OPERATION ........................................................................................10
To Arm the System and Leave .......................................................................10
When the System is Not Ready ......................................................................11
To Arm the System and Stay Inside ...............................................................11
To Arm the System In Instant Mode and Stay Inside ..................................... 12
To Arm the System In Instant Mode ...............................................................13
To Bypass a Zone ...........................................................................................13
To Unbypass a Zone.......................................................................................14
Disarming the System ..................................................................................... 14
USER CODES......................................................................................................16
Adding/Changing a User Code .......................................................................16
Deleting a User Code......................................................................................16
PAGING FEATURE..............................................................................................17
Follow-Me Displays .........................................................................................17
Changing the Pager Follow-Me Phone Number .............................................17
MISCELLANEOUS COMMANDS ........................................................................19
TESTING THE SYSTEM......................................................................................22
System Test .................................................................................................... 22
Battery Test.....................................................................................................22
RECOMMENDATIONS ON SMOKE DETECTORS ............................................ 23
EMERGENCY EVACUATION..............................................................................24
RADIO FREQUENCY EMISSIONS STATEMENTS.................................... 25
FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15....................... 25
TELEPHONE/MODEM INTERFACE STATEMENTS ................................. 25
TELEPHONE OPERATIONAL PROBLEMS.................................................26
O560 DECLARATION OF CONFORMITY...............................................26
SYSTEM LIMITATIONS.......................................................................................27
GLOSSARY..........................................................................................................29
– 4 –
Quick Reference
Arming the System
Check to make sure the system is ready — Green READY LED is lit.
Enter your 4-digit User Code (or press the ARM button on your
keyfob).
The ARMED LED goes on.
Exit through a door designated by your installer as an exit/entry door.
Disarming the System
Enter through door designated by your installer as an exit/entry door.
Enter your 4-digit User Code (or press the DISARM button on your
keyfob).
The ARMED LED goes out.
Arm System/Stay Inside
Check to make sure the system is ready — Green READY LED is lit.
Press STAY followed by your User Code.
The ARMED and STAY LEDs light.
You must disarm the system if you want to open the door or leave the premises
after the exit time has passed.
Arm System/Stay Inside/Instant Mode
Check to make sure the system is ready — Green READY LED is lit.
Press INSTANT then STAY followed by your User Code.
The ARMED, INSTANT, and STAY LEDs are all lit.
Smoke Detector Reset
Enter your 4-digit User Code.
– 5 –
Quick Reference (cont’d)
The following table lists the “Quick Commands” available with this control.
Keystroke Quick Command Keypads Description
# 1 Quick Arm All keypads If system is ready, allows you to arm the system without
requiring your User Code. Your User Code is always
needed to disarm the system.
# 2 Force Arm All keypads Allows you to arm the system even if some zones are
faulted. These zones are automatically bypassed and are
unprotected.
[BYPASS] +
Zone No.
Quick Bypass All keypads Allows you to bypass a specific zone number. Must be
enabled by your installer.
# 3 Set Time All keypads Allows entry of the current system time (hours, minutes,
month, day, year).
# 4 Zone Directory LCD only Displays listing of zones in system.
# 55 Display Firmware Version LCD only Displays version of your OMNI-408 firmware.
# 56 Display Keyfob Battery Status All keypads Allows you to test battery status of your keyfob. Upon
entry of this mode, press any button on the keyfob and the
keypad will display if your battery is low.
# 58 Change/View Pager Number All keypads Allows you to redirect pager output to a different pager
number. Phone numbers are displayed only on LCD
keypads.
# 6 Display/Toggle Chime Mode All keypads Allows you to change the status of the chime function.
# 7 Display Current Time LCD only Allows you to view the current system time.
# 8 User Page Toggle All keypads Allows you to turn the pager mode on or off. Keypad
displays the current system status.
– 6 –
Introduction
Congratulations on your decision to protect your home or business
with the OMNI®-408 security system. You have chosen a reliable,
state-of-the-art security system that is remarkably easy to operate.
Representatives from your local security company, who can explain
the specifics of your system, have professionally installed your system.
The keypad is the input and display device for your security system.
Your system can use either the OMNI-KP, OMNI-KP-US, OMNI-LCD,
OMNI-LCD-US, XK7LC, or XK108 keypads. The OMNI-KP and
OMNI-KP-US keypads display the system status with fixed words, the
OMNI-LCD, OMNI-LCD-US, and XK7LC keypads display two lines of
text, and the XK108 keypad displays the current zone status,
including alarms, bypasses, and faults, using LEDs. Each condition
causes the LEDs to operate differently.
Throughout this guide, the following conventions are used to display
the keystrokes required to perform functions.
BYPASS Key labeled [BYPASS]
INSTANT Key labeled [INSTANT]
STAY Key labeled [STAY]
CODE Key labeled [CODE]
Enter your four-digit User Code.
Please keep your guide in a convenient location so you can refer to it if
needed.


Produktspezifikationen

Marke: Honeywell
Kategorie: Sicherheit
Modell: OMNI-408

Brauchst du Hilfe?

Wenn Sie Hilfe mit Honeywell OMNI-408 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Sicherheit Honeywell

Bedienungsanleitung Sicherheit

Neueste Bedienungsanleitung fĂĽr -Kategorien-