Honeywell HPA304 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Honeywell HPA304 (12 Seiten) in der Kategorie Luftreiniger. Dieser Bedienungsanleitung war für 11 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/12
IMPORTANT SAFETY
INSTRUCTIONS
READ AND SAVE THESE
SAFETY INSTRUCTIONS
BEFORE USING THIS
AIR PURIFIER
When using electrical appliances, basic
precautions should always be followed to
reduce the risk of fire, electric shock, and
injury to persons, including the following:
1. Read all instructions before operating the
air purifier.
2. Place air purifier where it is not easily
knocked over by persons in the household.
3. Always turn the air purifier controls to the
OFF position and unplug from the wall
outlet when not in use.
4. To disconnect the air purifier, make sure
the unit is powered OFF then grip the plug
and pull it from the wall outlet. Never pull
by the cord.
5. Do not use any product with a damaged
cord or plug or if product malfunctions, is
dropped or damaged in any manner. Keep
the cord away from heated surfaces.
6. Do not use air purifier outdoors.
7. Never use air purifier unless it is
fully assembled.
8. Do not run power cord under carpets, and
do not cover with throw rugs. Arrange
cord such that it will not be tripped over.
9. Do not use air cleaner where combustible
gases or vapors are present.
10. Do not expose the air purifier to rain, or
use near water, in a bathroom, laundry
area or other damp location.
11. The air purifier must be used in its upright
position.
12. Do not allow foreign objects to enter
ventilation or exhaust opening as this may
cause electric shock or damage to the air
purifier. Do not block air outlets or intakes.
13. Locate air purifier near the outlet and
avoid using an extension cord.
14. This appliance has a polarized plug (one
blade is wider than the other). To reduce
the risk of shock, this plug is intended to
fit only one way in a polarized outlet. If the
plug does not fit fully in the outlet, reverse
the plug. If it still does not fit, contact a
qualified electrician.
DO NOT attempt to defeat this safety
feature.
15. A loose fit between the AC outlet
(receptacle) and plug may cause
overheating and a distortion of the plug.
Contact a qualified electrician to replace
loose or worn outlet.
16. Do not sit, stand or place heavy objects on
the air purifier.
17. Disconnect power supply before servicing.
18. SAVE THESE INSTRUCTIONS.
WARNING: To Reduce The Risk of Fire or
Electric Shock, Do Not Use This Air Purifier
With Any Solid-State Speed Control Device.
THE DOCTOR’S CHOICE
TRUE HEPA
ALLERGEN REMOVER
AIR PURIFIERS
For Models: HPA090 series, HPA100 series,
HPA200 series & HPA300 series
The Honeywell Trademark is used by Kaz USA, Inc. under license from Honeywell International Inc.
Honeywell International Inc. makes no representation or warranties with respect to this product.
2 3
HPA100 series, HPA200 series, HPA300 series
Type
R
A
A
R
Odor Reducing Pre-Filter
or
R
A
A
R
Household Gas
& Odor Reducing Pre-Filter
Front Grille
YOUR AIR PURIFIER
SET-UP
• Select a firm, level and flat location.
• When operating, large volumes of air are drawn toward the air purifier. Surrounding areas should be
cleaned and/or vacuumed frequently to prevent build-up of dust and other contaminates. This may
also help prolong the life of the filter. If the unit is placed on a light colored carpet, a small mat or rug
should be used underneath to prevent permanent staining. This is especially important in homes with
contamination from smoking, fireplaces, or where candles are burned.
• Ensure the front of the unit faces away from the closest wall or furniture.
• Ensure no grilles are blocked.
Control Panel
HPA090 series
Type R
AA
R
True HEPA
Filter (1)
Type
R
AA
R
Odor Reducing
Pre-Filter or
R
A
A
R
Household Gas &
Odor Reducing Pre-Filter
Front Grille
The True HEPA Filters and Odor Reducing Pre-Filter are supplied within the air purifier. New air purifiers
have their filters wrapped to ensure purity, and are labeled to help identify the proper replacement filter.
(Type
R
AA
R
True HEPA Filter; Type
R
AA
R
Odor Reducing Pre-Filter or
R
AA
R
Household Gas & Odor Reducing Pre-Filter)
• Before using your new air purifier you must remove the wrappers covering the filters and Pre-Filter.
Make sure the air purifier is OFF and unplugged. Press the two hand symbols () on the front grille to
release it from the unit and pull the grille toward you to remove it (see Fig. 2). Grasp the sides of the
filter frame near its top end and pull outward. Repeat for the second and third
filter if applicable.
• Remove protective wrap from the filters (including the Pre-Filter) that have
been supplied with your air purifier.
• Place the HEPA filter(s) into the air purifier housing. Ensure that the removal
“pull” tabs are facing outward (this will facilitate filter removal later). Place the
Pre-Filter on top of the HEPA filter(s). Tuck the edges of the Pre-Filter into the
tabs that are located around the edges of where the HEPA filter(s) are inserted.
This will hold the Pre-Filter securely in place.
• Replace the front grille by placing the tabs on the bottom of the grille into the
slot(s) on the unit. Gently push the top of the grille into place by pressing on the hand symbols () to
secure in place.
Control Panel
Type R
AA
R
True HEPA Filters
HPA100 HPA300HPA200
HOW YOUR AIR PURIFIER WORKS
This model air purifier incorporates a 2-stage cleaning
system to help clean the air that passes through the
filter in the unit (Fig. 1).
Stage 1: Odor Reducing Pre-Filter
Stage 2: True HEPA Filter that captures
particles as small as 0.3 microns or larger
2
Filter(s)
Odor Reducing
Pre-Filter
STAGE 1 STAGE 2
Fig. 1
SET-UP
INSTALL TRUE HEPA FILTERS AND ODOR REDUCING PRE-FILTER
Fig. 2
4 5
This product earned the ENERGY STAR rating by meeting strict energy efficiency guidelines set by
the U.S. EPA. The U.S. EPA does not endorse any manufacturer claims of healthier indoor air from
the use of this product.
Portable air purifiers are more effective in rooms where all doors and windows are closed. In general, it is
recommended that you run your air purifier while you are at home to clean the air.
HPA090 Series Operation:
• Once the filters have been unwrapped and replaced in the unit, ensure the
air purifier’s control knob is turned to the OFF position and plug the power
cord into a working electrical outlet.
• Select the desired cleaning level by turning the knob to General Clean,
Allergen or Turbo setting (Fig. 3).
• The Turbo setting will operate the air purifier at the highest speed. This
setting will maximize the unit’s ability to help reduce odors and will help clean the air quickly if you have
a specific air quality issue that needs to be addressed.
• The Allergen setting will effectively help reduce airborne allergen from the air that passes through the filter.
HPA100, 200, 300 Series Operation:
• Once the filters have been unwrapped and
replaced in the unit, plug the power cord into a
working electrical outlet.
• Select the desired cleaning level by simply
TAPPING the power symbol ( ) to toggle through
the setting options. A blue LED light will illuminate the selected setting: Germ, General Clean or Allergen.
TAP POWER ( ) for on/off & cleaning level selection.
ALLERGEN optimizes allergen capturing performance during allergen season.
GENERAL CLEAN for general, everyday air cleaning.
GERM optimizes germ capturing performance. Use during cold & flu season.
TAP TURBO () for power cleaning or fast odor reduction.
• The Turbo setting operates the unit at the highest speed. This setting will maximize the unit’s ability to
help reduce odors and will help clean the air quickly. To select the Turbo setting the unit must already
be running at one of the 3 cleaning settings, TAP the Turbo icon ( ). The Turbo LED will illuminate.
TAPPING the Turbo icon ( ) again will return the air purifier to the previous cleaning setting. To shut
OFF, tap the Power symbol ( ) until the air purifier shuts off.
Using the Timer Option (Not available on the HPA090 Series):
The Timer Option ( ) allows you to select how long the air purifier will run before
it automatically shuts off. There are three pre-set run times: 2, 4, and 8 hours. Do
not use this option if you want the unit to run continuously.
• To set the unit for Automatic Shut Off, TAP the Auto-off Timer icon ( ).
• Continue to TAP to toggle through to the desired time setting.
• An LED light will illuminate to indicate the selected run time (Fig. 5).
• The unit will automatically shut off after the indicated run time.
MAINTAINING YOUR STAGE 1 WASHABLE PARTICLE PRE-FILTERREPLACING THE TRUE-HEPA FILTERS
See INSTALLATION INSTRUCTIONS on page 3 of this manual.
You may be able to purchase Honeywell replacement True-HEPA filter
R
AA
R
for your air purifier at the store
where you purchased your air purifier or they can be ordered directly from Kaz USA, Inc., the licensee of
Honeywell air purifiers at www.replacementfilters.com. If you have any questions, contact Kaz Consumer
Services at 1-800-477-0457.
Please note that each model series takes a different number of HEPA filters: HPA090 and HPA100 Series use 1 HEPA
R
AA
R
Replacement Filter, HPA200 Series use 2 HEPA R
Replacement Filters , HPA300 Series use 3 HEPA R
AA
R
Filters
These air purifier models each have two electronic filter checks to remind you
when to check and replace the True-HEPA filters and the Odor Reducing Pre-
Filters based on the air cleaner’s hours of use.
When the True HEPA filter(s) and/or the Pre-Filter need to be replaced, the
“Check Filter” or “Check Pre-Filter” light will illuminate (Fig. 7).
You should periodically check these filters. Depending on operating conditions,
the True-HEPA filters should be replaced every 12 months, and the Odor
Reducing Pre-Filters every 3 months, especially if there have been heavy odors
and particles in the home.
To RESET Either Electronic Filter Check:
After you have replaced the appropriate filter(s) the “Check Filter or “Check Pre-Filter” light will remain
on until it is reset. With the unit powered on, press the lighted button and hold for approximately 2
seconds until the light turns off. The electronic filter check is now reset. Depending on individual usage
(environment and hours used), you may need to replace filters more or less frequently.
NOTE: If you change the Pre-Filter or Filter before the Electronic Filter Check lights are illuminated, it is
possible to re-set the light indicators. With the unit plugged in, but NOT powered on, press and hold each
button individually for at least 5 seconds. This will illuminate the indicator light. After the light turns on,
individually press and hold the “Check Filter” or “Check Pre-Filter” button until each light goes off. At this
point, the filter indicator will be re-set to it’s original “clean” status.
These cleaning intervals are intended as guidelines only. Performance of any filter media is dependent
upon the concentration of contaminates going through the system. High concentrations of contaminates
such as dust, pet dander and smoking will reduce the useful performance of the filter.
NOTE: None of the filters are washable. Do not immerse them in water.
ELECTRONIC FILTER CHANGE REMINDER
Fig. 7 Will illuminate
when it is time to
change HEPA filters
OPERATION
Fig. 5 Timer Function
Using the Dimmer Option (Not available on the HPA090 Series)
The Dimmer Option ( ) allows you to adjust the brightness of the LED displays on
the control panel (Fig. 8). You may wish to adjust the brightness depending on the
room where the unit is placed. The unit always turns on with the brightness on HIGH.
To adjust brightness:
• TAP the Dimmer icon ( ) once to dim the lights to LOW.
• TAP the Dimmer icon ( ) twice and it will shut the lights OFF. (the air purifier
will not shut off).
• TAPPING the Dimmer icon ( ) a third time will return the brightness to HIGH.
Fig. 6 Dimmer Function
Fig. 3 HPA090 Control Panel
Fig. 4 HPA100, HPA200, HPA300 Control Panel


Produktspezifikationen

Marke: Honeywell
Kategorie: Luftreiniger
Modell: HPA304

Brauchst du Hilfe?

Wenn Sie Hilfe mit Honeywell HPA304 benĂśtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Luftreiniger Honeywell

Bedienungsanleitung Luftreiniger

Neueste Bedienungsanleitung fĂźr -Kategorien-