Homedics FB-200 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Homedics FB-200 (8 Seiten) in der Kategorie Fussbäder. Dieser Bedienungsanleitung war für 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/8
Hydro-Therapy Foot
Massager
Instruction Manual and
Warranty Information FB-200
El manual en español
empieza a la página 9
P
l
e
a
s
e
T
a
k
e
A
M
o
m
e
n
t
N
o
w
Register
Your Product At:
www.homedics.com/register
Your valuable input regarding this
product will help us create
the products you will
want in the future.
©2011 HoMedics, Inc. y sus compañías afiliadas, reservados todos los derechos. HoMedics® es una marca
registrada de HoMedics, Inc. y sus compañías afiliadas. Reservados todos los derechos.
IB-FB200
GARANTÍA LIMITADA POR DOS AÑOS
HoMedics vende sus productos con la intención de que no tengan defectos de fabricación ni de mano de
obra por un plazo de dos años a partir de la fecha de compra original, con las siguientes excepciones.
HoMedics garantiza que sus productos no tendrán defectos de material ni de mano de obra bajo
condiciones de uso y servicio normales. Esta garantía se extiende únicamente a consumidores y no a
distribuidores.
Para obtener servicio para su producto HoMedics, envíe por correo el producto y su recibo de compra
fechado (como comprobante de compra), con franqueo pago, a la siguiente dirección:
HoMedics Service Center
Dept. 168, Suite 3
43155 West Nine Mile Rd
Novi, MI 48375
No se aceptarán pagos contra entrega.
HoMedics no autoriza a nadie, incluyendo, pero sin limitarse a, distribuidores, posteriores consumidores
compradores del producto a un distribuidor, o compradores remotos, a obligar a HoMedics de forma
alguna más allá de las condiciones aquí establecidas. La garantía de este producto no cubre daños
causados por uso inadecuado o abuso, accidente, conexión de accesorios no autorizados, alteración
del producto, instalación inadecuada, reparaciones o modificaciones no autorizadas, uso inadecuado
de la fuente de energía/electricidad, cortes de energía, caída del producto, funcionamiento incorrecto o
daño de una pieza de funcionamiento debido al no cumplimiento del mantenimiento recomendado por
el fabricante, daños durante el transporte, robo, descuido, vandalismo, condiciones climáticas, pérdida
de uso en el período durante el cual el producto está en una instalación de reparación o a la espera de
piezas o reparación, o cualquier otra condición, sin importar cual sea, que se encuentre fuera del control
de HoMedics.
Esta garantía es válida únicamente si el producto es comprado y operado en el país en el cual se comp
el producto. Un producto que requiera modificaciones o adaptación para habilitar su funcionamiento
en cualquier país que no sea aquél para el que fue diseñado, fabricado, aprobado y/o autorizado, o la
reparación de productos dañados por estas modificaciones no están cubiertos bajo esta garantía.
LA GARANTÍA AQUÍ ESTABLECIDA SERÁ LA ÚNICA Y EXCLUSIVA GARANTÍA. NO HABRÁ NINGUNA
OTRA GARANTÍA EXPRESA NI IMPLÍCITA, INCLUYENDO NINGUNA GARANTÍA DE COMERCIALIZACIÓN
O APTITUD NI NINGUNA OTRA OBLIGACIÓN POR PARTE DE LA COMPAÑÍA CON RESPECTO A
PRODUCTOS CUBIERTOS POR ESTA GARANTÍA. HOMEDICS NO TENDRÁ RESPONSABILIDAD
ALGUNA POR NINGÚN DAÑO INCIDENTAL, CONSECUENTE NI ESPECIAL. BAJO NINGÚN CONCEPTO
ESTA GARANTÍA REQUERIRÁ MÁS QUE LA REPARACIÓN O CAMBIO DE ALGUNA PIEZA O PIEZAS
QUE SE HALLEN DEFECTUOSAS DENTRO DEL PERÍODO DE VIGENCIA DE ESTA GARANTÍA. NO SE
EFECTUARÁN REEMBOLSOS. SI NO HAY PIEZAS DE REPUESTO DISPONIBLES PARA LOS MATERIALES
DEFECTUOSOS, HOMEDICS SE RESERVA EL DERECHO DE REALIZAR SUSTITUCIONES EN VEZ DE
REPARAR O CAMBIAR.
Esta garantía no se extiende a la compra de productos abiertos, usados, reparados, embalados otra vez
y/o abiertos y vueltos a cerrar, incluyendo entre otras cosas la venta de dichos productos en sitios de
remate por Internet y/o la venta de dichos productos por revendedores o mayoristas. Todas y cada una
de las garantías cesarán y terminarán inmediatamente con respecto a cualquier producto o pieza del
mismo que estén reparados, cambiados, alterados o modificados sin el consentimiento previo explícito
y por escrito de HoMedics.
Esta garantía le proporciona derechos legales específicos. Es posible que usted tenga derechos
adicionales que pueden variar de un país a otro. Debido a las regulaciones de ciertos países, es posible
que algunas de las limitaciones y exclusiones no se apliquen en su caso.
Por más información con respecto a nuestra línea de productos en los EE.UU., visítenos en:
www.homedics.com
Dirección postal:
HoMedics Service Center
Dept. 168, Suite 3
43155 West Nine Mile Rd
Novi, MI 48375
correo electrónico:
cservice@homedics.com
Lunes - Viernes
8:30am - 7:00pm (EST)
1.800.466.3342
2 3
IMPORTANT SAFEGUARDS
WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN
CHILDREN ARE PRESENT, BASIC SAFETY PRECAUTIONS
SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE USING
DANGER
- TO REDUCE THE RISK OF ELECTRIC SHOCK:
Always unplug the appliance from the electrical outlet immediately after using and
before cleaning.
DO NOT reach for an appliance that has fallen into water. Unplug it immediately.
Do not place or store appliance where it can fall or be pulled into a tub or sink.
Do not place in or drop into water or other liquid.
WARNING
- TO REDUCE THE RISK OF BURNS, ELECTRIC
SHOCK, FIRE OR INJURY TO PERSONS:
An appliance should never be left unattended when plugged in. Unplug from outlet when not
in use and before putting on or taking off parts or attachments.
Close supervision is necessary when this appliance is used by, on, or near children, invalids,
or disabled persons.
Use this appliance only for its intended use as described in this manual. Do not use
attachments not recommended by HoMedics; specifically any attachments not provided with
the unit.
NEVER operate this appliance if it has a damaged cord or plug, if it is not working properly,
if it has been dropped or damaged, or dropped into water. Return it to HoMedics Service
Center for examination and repair.
Keep cord away from heated surfaces.
NEVER drop or insert any object into any opening.
DO NOT operate where aerosol (spray) products are being used or where oxygen is being
administered.
DO NOT operate under a blanket or pillow. Excessive heating can
occur and cause fire, electrocution, or injury to persons.
DO NOT carry this appliance by the power cord or use the cord as
a handle.
To disconnect, turn all controls to the “off” position, then remove
the plug from the outlet.
DO NOT use outdoors.
NEVER operate this appliance with the air openings blocked. Keep
the air openings free of lint, hair, and the like.
DO NOT attempt to stand on or in your HoMedics foot massager.
Use only while seated.
Use heated surfaces carefully. May cause serious burns. Do
not use over insensitive skin areas or in the presence of poor
circulation. The unattended use of heat by children or
incapacitated persons may be dangerous.
DO NOT handle plug with wet hands.
SAVE THESE INSTRUCTIONS
CAUTION—PLEASE READ ALL INSTRUCTIONS
CAREFULLY BEFORE OPERATING.
This product is not intended for medical use. It is intended only to
provide a luxurious massage.
Consult your doctor prior to using this product, if
- You are pregnant
- You have a pacemaker
- You have any concerns regarding your health
Consult your doctor before using this unit if you have diabetes,
as diabetes can contribute to foot problems including decreased
feeling or circulation to the feet. Given the existing risk of foot
problems for diabetics, this unit must not be used prior to
consulting your doctor.
DO NOT attempt to plug or unplug unit while feet are in the water.
Use appliance on a sturdy or level surface.
Do not use this product for more than 30 minutes at a time.
Extensive use could lead to the product’s excessive heating and
shorter life. Should this occur, discontinue use and allow the unit to
Caution:
All servicing of
this massager
must be
performed by
authorized
HoMedics service
personnel only.
4 5
cool before operating.
Never use any foot massager on open wounds, discolored areas, or any area of the body
that is swollen, burned, inflamed, or where skin eruptions or sores are present.
If you experience pain in a muscle or joint for a prolonged period of time, discontinue use
and consult a doctor. Persistant pain could be a symptom of a more serious condition.
DO NOT use while sleepy or drowsy.
Use of this product should be pleasant and comfortable. Should pain or discomfort result,
discontinue use and consult your physician.
This product should NEVER be used by any individual suffering from any physical ailment
that would limit the user’s capacity to operate the controls, or who has sensory deficiencies.
Always unplug the unit when filling or moving the unit.
Ensure that your hands are dry when operating the controls or removing the plug.
Servicing of Double-Insulated Products
In a double-insulated product, two systems of insulation are provided instead of grounding. No
grounding means is provided on a double-insulated product, nor should a means for grounding
be added to the product. Servicing a double-insulated product requires extreme care and
knowledge of the system and should be done only by qualified service personnel. Replacement
parts for a double-insulated product must be identical to the parts they replace. A double-
insulated product is marked with the words “DOUBLE INSULATION” or “DOUBLE INSULATED”
The symbol may also be marked on the product.
Polarized Plug
To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than
the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the
outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper
outlet. Do not change the plug in any way.
Hydro-Therapy Foot Massager Features
4 Hydro-therapy water jets for a soothing foot massage
Invigorating vibration massage for your whole feet
Center massage node for manual massage of heels, arches, and toes
LED lighting for a more relaxing experience
Toe-touch controls
Heat helps maintain warm water temperature
Instructions for Use
1. Ensure that the unit is unplugged before filling with water. Fill with
warm water to the fill line located on the inside of the tub.
NOTE: Heat will only help to maintain the temperature of water
placed inside the foot massager. It will not heat cold water. For a
warm water massage, fill the unit with warm water.
2. Plug the unit into a 120 volt household outlet.
3. Sit down in a comfortable position. With the touch of your toe, press
the on/off button.
4. Select hydro-therapy water jet massage, vibration massage, or both
by pressing the corresponding buttons on the control panel.
5. Manually massage your heels, arches, and toes by rubbing your
feet over the center massage node.
6. To empty: first, unplug the unit. Take the foot massager to the
closest drain and tip the unit allowing water to pour out along the
drain spout. DO NOT pour water over the control panel.
Maintenance
To Clean
Unplug the unit and allow it to cool before cleaning. Clean only with a
soft, damp cloth and mild cleansing agent.
After cleaning, wipe surfaces with a dry cloth.
Never use strong abrasives, detergents or cleansing agents.
Periodically straighten cord if it becomes twisted.
To Store
Unplug the appliance from the outlet and allow to cool and dry.
Store in its box or a clean, dry place.
To avoid breakage, do not wrap the power cord around the unit.
Do not hang the unit by the power cord.
This appliance is designed for household use only.
Caution:
To avoid injury
and irreparable
damage, always
remain seated
when using this
foot massager.
Never stand on
or in the unit.
CAUTION: THIS
UNIT CAN ONLY
RUN WITH
WATER IN IT.
DO NOT USE
WITHOUT
WATER.
CAUTION:
DO NOT FILL WATER OVER THE FILL LINE


Produktspezifikationen

Marke: Homedics
Kategorie: Fussbäder
Modell: FB-200

Brauchst du Hilfe?

Wenn Sie Hilfe mit Homedics FB-200 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten