Wiring Diagram
The Heatmiser DS1-EL dial type thermostat is designed
specically for electric underoor heating.
This thermostat incorporates the following functions;
• Adjustable Switching Dierential
• Digital LCD
• 230v AC, 13A Switching
Introduction 1
4
Model: DS1-EL
RCD
MAINS SUPPL
Y
L N
MATTING OR WIRE
FlOOR PROBE
DS1-EL
Want More Information?
Call our support team on:
+44 (0)1254 669090
Or view technical specications
directly on our website:
www.heatmiser.com
IN ORDER TO AVOID ANY RISK OF ELECTRIC SHOCK, TURN OFF THE POWER TO THE
HEATING SYSTEM.
This dial thermostat is designed to be surface mounted.
1. Separate the front part of the thermostat by unscrewing securing screws on the
bottom face of the thermostat.
2. Mark 2 hole positions on the wall using the backplate as a positioning template. Drill at
the marked positions and insert a wall plug in to each hole.
3. Terminate the thermostat as per wiring diagram and screw the DS1-EL back plate to the
back box.
4. Reconnect the thermostat front plate and insert the securing screws.
Installation
PDF FAQ
2
3
In normal mode, the display shows the actual room temperature. To change the set point,
rotate the dial until the digital LCD displays the new set temperature.
Setting The Temperature
Display Icons
The Heatmiser DS1-EL has a lock facility. To lock the thermostat, press and hold down the
dial for 10 seconds. You will see a lock symbol appear. To unlock, repeat the steps above.
Heating ON Keypad Locked
The Heatmiser DS1-EL oers 1, 2 and 3°C switching dierential.
With a 1°C switching dierential the heating will switch on 1°C below the set
temperature and will turn o when the set temperature is reached.
A 2°C will turn the heating on 2°C below the set temperature.
3°C will switch the heating on 3°C below the set temperature.
To set the dierential, set the DIP switches according to the table below.
This setting is only required when the sensor option is set to Air and Floor mode.
The setting is used to protect the oor surface from overheating.
The oor temperature limit can be set to 20, 28 or 40°C.
To set the required oor limit temperature, set the DIP switches according to the table.
The thermostat has three modes of operation. Select the desired mode,
and set the DIP switches according to the table.
The DIP switches can be accessed from the back of thermostat.
Air Sensor: Uses the built in air sensor only.
Air Sensor & Floor Limiting Sensor: Uses the built in air sensor but also uses the
remote oor sensor to ensure the oor temperature doesn’t overheat.
Floor Sensor: Uses the remote oor sensor only.
Lock Facility
Switching DierentialFloor Temperature Limit
Sensor Option
1 2
1 °C Switching
2 °C Switching
3 °C Switching
20°C
28°C
40°C
Air Sensor
Air & Floor
Floor Sensor
1
2
3
1
2
3
1
2
3
Switch 1 & 2 OFF
Switch 1 ON and Switch 2 OFF
Switch 1 OFF and Switch 2 ON
Switch 5 & 6 OFF
Switch 5 ON and Switch 6 OFF
Switch 5 OFF and Switch 6 ON
Switch 3 & 4 OFF
Switch 3 ON and Switch 4 OFF
Switch 3 OFF and Switch 4 ON
22
2
33
3
11
1
Should the oor temperature be achieved (even if the desired room temperature has
not) the heating will turn o. The Heat Active Icon will ash in this case.
Produktspezifikationen
Marke: | Heatmiser |
Kategorie: | Thermostate |
Modell: | DS1-EL |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Heatmiser DS1-EL benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Thermostate Heatmiser
14 Oktober 2024
10 Oktober 2024
7 August 2024
7 August 2024
7 Juli 2024
5 Juli 2024
5 Juli 2024
Bedienungsanleitung Thermostate
- Thermostate AEG
- Thermostate Siemens
- Thermostate EMOS
- Thermostate Renkforce
- Thermostate Elro
- Thermostate Vaillant
- Thermostate Honeywell
- Thermostate Junkers
- Thermostate Zehnder
- Thermostate Theben
- Thermostate Aermec
- Thermostate Coati
- Thermostate Sygonix
- Thermostate Orbis
- Thermostate Eberle
- Thermostate BTicino
- Thermostate Danfoss
- Thermostate Delta Dore
- Thermostate Fantini Cosmi
- Thermostate Grässlin
- Thermostate Heimeier
- Thermostate Oventrop
- Thermostate Salus
- Thermostate Seitron
- Thermostate Drayton
- Thermostate Emerson
- Thermostate ICY
- Thermostate Plieger
- Thermostate Watts
- Thermostate Horstmann
- Thermostate White Rodgers
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
15 Oktober 2024
14 Oktober 2024
14 Oktober 2024
14 Oktober 2024
12 Oktober 2024
11 Oktober 2024
11 Oktober 2024
11 Oktober 2024